YY/T 0764-2025Ophthalmic instruments - Projected and electronic chart displays for visual acuity measurement (English PDF)
国家药品监督管理局
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0764-2025 in 30 minutes.
Issued by
National Medical Products Administration
Level / Type
National · Recommended
Issue date
June 18, 2025
Implementation date
July 1, 2026
Scope
YY/T 0764-2025 is the English-translated version of 国家药品监督管理局.
YY/T 0764-2025 — This document specifies the requirements, accompanying documents, and standards for projections and electronic vision charts (hereinafter referred to as "vision charts") used for measuring visual acuity.
The record describes the corresponding experimental methods. This document applies to projections and electronic vision charts used for measuring visual acuity.
Found what you need?
Document preview — YY/T 0764-2025
National Standard of the People's Republic of China
- ICS
- 11.040.70
- Classification
- C 40
- Replacing
- YY/T 0764-2009
Issued by: National Medical Products Administration
Contents
- Preface
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 Requirements
- 4.1 Visual Target
- 4.2 Specific requirements for projected visual acuity charts
- 4.3 Scope of Compliance
- 4.4 General Requirements
- 4.5 Electrical Safety
- 4.6 Electromagnetic Compatibility
- 5 Test Methods 7.
- 5.1 Overview
- 5.2 Visual Target
- 5.3 Specific requirements for projected visual acuity charts
- 5.4 Scope of Compliance
- 5.5 General Requirements
- 5.6 Electrical Safety
- 5.7 Electromagnetic Compatibility
- 6 Accompanying documents 9.
- 7 Mark
- Appendix A (Informative) Structure Numbering Comparison Table
- Appendix B (Informative) Summary of Technical Differences and Their Reasons Table
- Reference
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".
Drafting.
This document replaces YY/T 0764-2009 "Ophthalmic Instruments - Visual Acuity Chart Projector". Compared with YY/T 0764-2009, the only changes are in the structural design.
Aside from integration and editorial changes, the main technical changes are as follows.
---The terminology and definition of "visibility target" have been changed (see 3.1, 2009 edition of 3.1);
---The term and definition of "node" have been removed (see 3.4 in the 2009 edition);
---The term and definition of "visual acuity" have been added (see 3.4);
---Added the terminology and definition of "Snelen score" (see 3.5);
---Added the term and definition of "decimal acuity" (see 3.6);
---Added the term and definition of "LogMAR sensitivity" (see 3.7);
---Added the terminology and definition for "5-point record" (see 3.8);
---Added the terminology and definition for "visual acuity level" (see 3.9);
---The term and definition of "resolution" have been added (see 3.10);
---The term "projection range" and its definition have been added (see 3.11);
---Added the term and definition of "pixel" (see 3.12);
---Added the terminology and definition for "critical details" (see 3.13);
---Added requirements for "target size" (see 4.1.2);
---The requirements for "Visual Acuity Level and Number of Presentations" have been changed, adding Snelen score and LogMAR for Visual Acuity Level.
The requirements for sensitivity, the representation of 5-point records, and the number of demonstrations (see 4.1.3, 4.2 in the 2009 edition);
---The requirements for "beacon spacing" have been changed (see 4.1.4, 4.3 in the 2009 version);
---The requirements for "background brightness" have been changed (see 4.1.5, version 4.5 from 2009);
---The requirements for "target contrast" have been changed (see 4.1.6, 4.5 in the 2009 version);
---Added requirements and test methods for "display quality" (see 4.1.7, 5.2.6);
---The requirement for "resolution" has been changed (see 4.1.8, 4.4 in the 2009 version);
---Added requirements and test methods for "projected vision chart screen" (see 4.2.2, 5.3.2);
---Added requirements and test methods for "compliance scope" (see 4.3, 5.4);
---Added "General Requirements" and test methods (see 4.4, 5.5);
---Added requirements and test methods for "electromagnetic compatibility" (see 4.6 and 5.7);
---The requirement for "environmental conditions" has been removed (see 4.7 in the 2009 edition).
This document is modified to adopt ISO 10938:2016 "Ophthalmic optics - Visual acuity charts for measurement of visual acuity - Printing, projection and electronic".
This document has undergone significant structural adjustments compared to ISO 10938:2016.A table comparing the structural numbering changes between the two documents is provided.
See Appendix A.
This document differs significantly from ISO 10938:2016.The relevant clauses are indicated in vertical margins.
Single lines (|) are indicated. A summary of these technical differences and their causes can be found in Appendix B.
The following editorial changes have been made to this document.
---The standard name has been changed;
---References have been added.
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed by the National Medical Products Administration.
This document was prepared by the Medical Optics and Instruments Subcommittee of the National Technical Committee on Standardization of Optics and Photonics (SAC/TC103/SC1) is under the jurisdiction of the relevant authorities.
1 Scope
This document specifies the requirements, accompanying documents, and standards for projections and electronic vision charts (hereinafter referred to as "vision charts") used for measuring visual acuity.
The record describes the corresponding experimental methods.
This document applies to projections and electronic vision charts used for measuring visual acuity.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB 9706.1 Medical electrical equipment – Part 1: General requirements for basic safety and basic performance (GB 9706.1-2020) IEC 60601-1:2012, MOD) YY 9706.102 Medical Electrical Equipment - Part 1-2.General Requirements for Basic Safety and Basic Performance (Parallel Standard). Electromagnetic Compatibility Requirements and tests (YY 9706.102-2021, IEC 60601-1-2:2007, MOD) ISO 15004-1 Ophthalmic instruments – Basic requirements and test methods – Part 1: General requirements for ophthalmic instruments
3 Terms and Definitions
The following terms and definitions apply to this document.
Optotype
Symbols used to measure visual acuity.
Standard Optotype
The Landolt ring beacon uses a circular "C" shape, with the width of the ring and the width of the notch on the ring both being one-fifth of the ring's diameter.
The "E" shaped sign uses a square "E" sign with three strokes of equal length, where the width or gap of each stroke is one-fifth of the side length of the square.
one.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 9706.1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- GB 9706.1-2020Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- YY 9706.102Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests
- YY 9706.102-2021Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests
IEC 60601 · ISO 15004
How to Download YY/T 0764-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.1-2020 — Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
GB 9706.103-2020 — Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance. Collateral Standard: Radiation protection in diagnostic X-ray equipment
GB 9706.12-1997 — Medical electrical equipment Part 1: General requirements for safety 3. Collateral standard: General requirements for radiation protection in diagnostic X-ray equipment
Secure payment via Stripe
Payments accepted
YY/T 0764-2025
$524.00