YY/T 0939-2014Ultrasound bone sonometers - Test method of broadband ultrasound attenuation (BUA) (English PDF)
超声骨密度仪 宽带超声衰减(BUA)的试验方法
Open the YY/T 0939-2014 preview as PDF
This is a limited preview
Buy now to download the full PDF (17 pages)
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 17, 2014
Implementation date
July 1, 2015
Scope
YY/T 0939-2014 is the English-translated version of 超声骨密度仪 宽带超声衰减(BUA)的试验方法.
YY/T 0939 is the test method for broadband ultrasound attenuation in bone sonometers, the quantity these instruments measure to assess bone status without ionising radiation. BUA describes how much a bone attenuates ultrasound across a band of frequencies, and it correlates with bone density and structure well enough to be used for screening, particularly at the heel. Because the measurement depends heavily on coupling, temperature and the geometry of the site, it is only comparable between instruments if the method is fixed, which is what this standard does. For a manufacturer or a distributor of quantitative ultrasound bone densitometers for the Chinese market, this is the method behind the measurement, and the reference a purchaser can use to compare instruments.
Document preview — YY/T 0939-2014
National Standard of the People's Republic of China
- ICS
- 11.040.50
- Classification
- C41
Issued by: National Medical Products Administration
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the China Food and Drug Administration. This standard by the standardization of medical ultrasound equipment for medical appliances National Standardization Technical Committee Technical Committee (SAC/TC10/SC2) Centralized. This standard was drafted. State Food and Drug Administration of Hubei Medical Device Quality Supervision and Inspection Center, Research Institute of Acoustics , Hefei University of Technology, GE Medical Systems (China) Co., Ltd. The main drafters of this standard. Jiang Shilin, Zhu Chenggang, Peng Hu, Hong-chun wave.
Broadband ultrasound attenuation (BUA) measurements and calculations, the details may be different for each manufacturer, for example, the transmission signal transducer Bandwidth and time-domain signal sampling frequency, the frequency range of the linear fit, are likely to cause broadband ultrasound attenuation (BUA) final results s difference. For these reasons, at present, broadband ultrasound attenuation (BUA) measured and calculated values has its uncertainties, namely two ultrasonic bone density measuring instrument It is possible to obtain different broadband ultrasound attenuation (BUA) values of the amount of the same sample for this problem, the standard set forth in addition to the usual broadband Ultrasound attenuation (BUA) test methods, also proposed a test method for measuring broadband ultrasound attenuation (BUA) relative value. Ultrasound bone densitometer Standard Test Method for broadband ultrasound attenuation (BUA) of
1 Scope
YY/T 0939 is the test method for broadband ultrasound attenuation in bone sonometers, the quantity these instruments measure to assess bone status without ionising radiation. BUA describes how much a bone attenuates ultrasound across a band of frequencies, and it correlates with bone density and structure well enough to be used for screening, particularly at the heel. Because the measurement depends heavily on coupling, temperature and the geometry of the site, it is only comparable between instruments if the method is fixed, which is what this standard does. For a manufacturer or a distributor of quantitative ultrasound bone densitometers for the Chinese market, this is the method behind the measurement, and the reference a purchaser can use to compare instruments.
Note 1. The pulse transmitter (device). generates electrical pulses for transmission probes use.
Note 2. The signal receiver (amplifier). for (amplification) of the received signal.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
YY 0774-2010 ultrasound bone densitometer
YY/T 0865.1-2011 ultrasonic hydrophone - Part 1. Measurement and features 40MHz describe the following medical ultrasound field
3 Terms and Definitions
Terms and definitions YY 0774-2010 and YY/T 0865.1-2011 defined apply to this document. Test Method 4
4.1 Test Environment Test environment should meet the environmental parameters specified by the manufacturer, such as temperature, humidity, air pressure and/or altitude.
4.2 Test Equipment See YY/T 0865.1-2011 Chapter 5 measurement requirements, test samples may be specified by the manufacturer, measurement method shown in Figure 1 FIG.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
YY 0774-2010
How to Buy YY/T 0939-2014
- 1Add to cart. Click the "Buy YY/T 0939-2014" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0492-2026 — Implantable leads
YY/T 0517-2026 — Dentistry - Posts
Secure payment via Stripe
Payments accepted
YY/T 0939-2014
$155.00