YY/T 0882-2013Anaesthetic and respiratory equipment—Compatibility with oxygen (English PDF)

麻醉和呼吸设备与氧气的兼容性

Preview PDF

This is a limited preview

Buy now to download the full PDF (43 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0882-2013 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

October 21, 2013

Implementation date

October 1, 2014

Scope

YY/T 0882-2013 is the English-translated version of 麻醉和呼吸设备与氧气的兼容性.

YY/T 0882-2013 is the Chinese pharmaceutical industry standard that sets the requirements for the compatibility with oxygen of anaesthetic and respiratory equipment.

It applies to the materials of which such equipment is made and to their use in contact with oxygen at a gas pressure above 50 kPa in normal condition or in single fault condition, and it sets out the minimum requirements for the choice of those materials, the ignition and combustion hazards they present and the way compatibility with oxygen is demonstrated. Issued on 21 October 2013, it has applied since 1 October 2014.

Found what you need?

Document preview — YY/T 0882-2013

National Standard of the People's Republic of China

ICS
11.040.10
Classification
C 46

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 R range
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

This standard is identical with ISO 15001:2003 "anesthesia and respiratory equipment - Compatibility with oxygen." Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.

Introduction

Whether pure oxygen or other medical gases and oxygen mixture, is widely used in the health care system. Because patients and caregivers often pick It means a high risk of contact with oxygen, oxygen-rich environment if ignited, causing serious injury. Common Cause is ignited by the compressed gas generation The presence of heat, hydrocarbons, and particulate contaminants will promote ignition. Some combustion products, especially some non-metal (such as plastic, rubber Rubber, lubricant) is toxic. So when a problem occurs, is receiving medical gas pipeline system from oxygen patients are likely to be injured, even far From the device.

Some devices use oxygen or oxygen equipment immediately as a device driver source if oxygen equipment malfunction, these devices may be Damaged or not working properly.

Reduce or avoid these risks depends on a suitable material, cleaning step, select the correct design and construction of the equipment, in order to use Under the conditions and oxygen compatible.

The standard for the safe use of oxygen system designed for use in oxygen-enriched environments and to establish the recommended minimum standards.

Appendix F contains the principle of some of the requirements of this standard description. Requirements and recommendations it contains this standard provides further explain release. Behind the label is marked with chapters in terms of R listed in Appendix F of the corresponding Rationale. Understanding these principles is not only conducive requirements Proper implementation of this standard, but also promote further amendments.

Specific standard device may refer to this standard, but may improve the minimum requirements in place.

1 R range

This standard specifies the anesthesia and respiratory equipment and material composition of oxygen in contact with the application, the gas pressure is higher than normal or 50kPa Minimum requirements under a single fault condition with oxygen compatibility.

This standard applies to anesthetic and respiratory equipment, such as. medical gas pipeline systems, pressure reducer, terminal, medical supply unit, a flexible connection, Meter apparatus, anesthesia workstations and ventilator.

This standard compatibility features include. cleanliness, flame retardancy, combustion and/or decomposition products toxicity.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

YY/T 0316-2008 medical device risk management to medical devices applications (ISO 14971:2007, IDT)

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Adiabatic compression

No heat conduction or transfer of import compression system.

3.2 Auto-ignition temperature

Under certain specific conditions, a material can spontaneously ignite temperature.

3.3 Lethal Concentration

LC50 So that a group of young adult rats (male and female) short-term (24h or less) exposed to a gas (or gas mixture) at once, 14d within the gas concentration at least half of the mice died. [ISO 10298:1995]

3.4 Oxygen index

In the mixed gas consisting of oxygen and nitrogen at 23 °C ± 2 °C, just to support a material under specific test conditions of combustion The minimum oxygen concentration [volume fraction (%) indicates]. [ISO 4589-2:1996]

3.5 Qualified technical personnel

Through education, training or experience between oxygen and other materials to understand the physical and chemical principles of personnel response.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 43 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0882-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
43 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0882-2013

$940.00