Valid

YY/T 1804-2021Anaesthetic and respiratory equipment-Spirometers intended for the measurement of time forced expired volumes in humans (English PDF)

麻醉和呼吸设备 用于测量人体时间用力呼气量的肺量计

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1804-2021 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

September 6, 2021

Implementation date

May 1, 2023

Scope

YY/T 1804-2021 is the English-translated version of 麻醉和呼吸设备 用于测量人体时间用力呼气量的肺量计.

YY/T 1804-2021 is the Chinese pharmaceutical industry standard for the spirometer used to assess lung function in people weighing more than 10 kg.

It sets the requirements for the instrument whatever the measuring principle: the accuracy of the volume and flow measurement over the required ranges, the resistance to breathing, the display and the printed record, the checks the user must be able to make including calibration with a syringe, and the accompanying documents.

It applies to any spirometer that measures forced expiratory volume against time, whether it stands alone or is part of a lung function system, and not to equipment for continuous patient monitoring. Issued on 6 September 2021, it has applied since 1 May 2023.

Found what you need?

Document preview — YY/T 1804-2021

National Standard of the People's Republic of China

Classification
C 46

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 General Requirements
  • 4.1 Electrical Safety
  • 4.2 Machinery Safety
  • 5 Identification, marking and documentation
  • 5.1 Scale or displayed markings
  • 5.2 Marking legibility
  • 5.3 Marking durability
  • 5.4 Marking of the spirometer or its packaging
  • 5.5 Instruction Manual
  • 5.6 Technical Specifications
  • 6 * Measuring range
  • 7 Performance Requirements
  • 7.1 Accuracy
  • 7.2 Recording time
  • 7.3 Graphics Display Aspect Ratio
  • 7.4 Volume recording
  • 7.5 * Exhale forcefully to start
  • 7.6 * Forced expiration to terminate
  • 7.7 Linearity
  • 7.8 Repeatability
  • 7.9 Expiratory Impedance
  • 8 Structural requirements
  • 8.1 Effects of Falling Handheld Spirometers or Accessories
  • 8.2 Calibration
  • 8.3 Disassembly and Reassembly
  • 9 Cleaning, Disinfection and Sterilization
  • 9.1 Reusable spirometers and parts
  • 9.2 Spirometers and their components requiring treatment prior to use
  • 9.3 Aseptically packaged spirometers and components
  • 10 Biocompatibility
  • Appendix A (Informative Appendix) Rationale
  • Appendix B (Normative Appendix) Test Accuracy, Linearity and Impedance of Spirometers
  • Appendix C (Normative Appendix) Defined Test Waveforms
  • Appendix D (Informative Appendix) Environmental Impact
  • Appendix E (Informative Appendix) Reference to the Basic Principles
  • Reference

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard uses the redrafted method to modify and adopts ISO 26782:2009 "Anesthesia and Respiratory Equipment for Measuring Human Time Forced Exhalation" Quantitative Spirometer.

The technical differences between this standard and ISO 26782:2009 and their reasons are as follows.

--- Regarding normative reference documents, this standard has made adjustments with technical differences to adapt to the technical conditions of our country and the circumstances of the adjustment.

The situation is reflected in Chapter 2 "Normative References", and the specific adjustments are as follows.

- Replacing IEC 60601-1:2005 with GB 9706.1-2020 modified to adopt international standards (see 4.1, 4.2, 8.1);

- Replace ISO 14937 with GB/T 19974 which is equivalent to adopting international standards (see 9.3);

- Replace ISO 10993-1 (see Chapter 10) with GB/T 16886.1 which is equivalent to adopting international standards.

--- Air flow direction indication of user-removable components sensitive to air flow direction, changed from "need to use arrow to indicate air flow direction" "There shall be an indication of the direction of airflow" [see 5.4.1a)]. This standard has made the following editorial changes.

Respiratory Society)", add "Respiratory Branch of Chinese Medical Association", and add references to Appendix D and Appendix E content;

---In 5.5.1a) "Note. In some countries, when the manufacturer does not have a local commercial registration, it is required to provide the name of the local authorized agent. name and address. "Revised" Note. When the manufacturer has no commercial registration in China, it is required to provide the name and address. ";

--- For editorial errors in ISO 26782:2009, this standard has been modified as follows.

- In the description of Figure A.1, "2---t0=0.75s" is changed to "2---t0=0.075s";

- In B.4.5, "n---Defined test waveform number (1~15)" is changed to "n---Defined test waveform number (1~13)";

- The first paragraph in Appendix C "Table C.1 contains the number of 10 test waveforms used to test the definition of the performance of the spirometer in Appendix B. "Spirometer" is replaced by "Table C.1 contains the mathematics of the 13 test waveforms used to test the definition of spirometer performance in Appendix B. expression".

Introduction

A spirometer is a medical device used to record physiological lung volumes within the spirometric range.

The volume of air that a patient can exhale within a certain period of time after maximal inspiration is a reliable method for evaluating lung function. Spirometry assessment It is used to screen individuals at risk for lung disease, to make objective measurements in the presence of lung disease, to assess symptoms and preoperative risk, and to document the efficacy of therapeutic interventions. fruit. Spirometers can also be used to evaluate lung disability, public health, and clinical trials.

Society) and the Chinese Society of Respiratory Medicine have played an important role in the standardization of pulmonary function tests including pulmonary function guidelines[6],[7] big effect. But so far there is no national spirometry standard to regulate the accuracy and repeatability of spirometry. Such standards are based on the customer A conceptual test method based on testing a series of carefully selected, well-defined test waveforms (such as those issued by ATS) tolerance.

The development of this standard solves this problem, allowing the spirometers used by clinicians to achieve accuracy, repeatability, electrical safety, etc. recognized standard.

The minimum safety requirements specified in this standard are for the purpose of using spirometers to ensure safety to a practical level. The relevant test specifications are given immediately following the requirements.

For some important requirements, see the rationale notes provided in the "Rationale" section in Appendix A. Learn about making these requests The reasons for this will not only facilitate the proper application of this standard, but will, in due course, be driven by changes in clinical practice or technological developments.

Push version revisions. However, this appendix is not a normative requirement of this standard.

In this standard, refer to the provisions providing the rationale in Appendix A, marked with an asterisk (*) in the text.

In this standard, see Appendix D for information on environmental impacts.

In this standard, see Appendix E for the correspondence between this standard and the basic principles of ISO /T R16142.

1 Scope

This standard specifies the requirements for a spirometer for use in assessing the lung function of persons weighing more than 10 kg.

This standard applies to all spirometers that measure forced expiratory volume over time, regardless of the measurement method used. Spirometer can be integrated part of a pulmonary function device, or a separate device.

This standard does not apply to equipment intended to continuously monitor patients.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB 9706.1-2020 Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance (IEC 60601-1. 2012, MOD)

GB/T 16886.1 Biological Evaluation of Medical Devices Part 1: Evaluation and Testing in Risk Management Process (GB/T 16886.1- 2011, ISO 10993-1:2009, IDT)

GB/T 19974 Characterization of Sterilization Factors for Sterilization of Healthcare Products and Development, Validation and Routine Control of Sterilization Processes for Medical Devices General requirements for (GB/T 19974-2018, ISO 14937:2009, IDT)

YY/T 0466.1-2016 Medical Devices Symbols for Medical Device Labeling, Marking and Providing Information Part 1: General Requirements Seek (ISO 15223-1:2012, IDT)

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Accessories accessory

Additional parts for use with spirometers to.

--- achieve the intended use;

--- make the equipment suitable for some specific purposes;

---Easy to use the equipment;

--- enhance the performance of the equipment; or ---Enable certain functions in order to integrate with certain functions of other devices.

Note. Modified from GB 9706.1-2020, definition 3.3.

3.2 Random document

Documentation accompanying the spirometer or accessory that contains information on operations responsible for the installation, use and maintenance of the spirometer or accessory information provided by the operator or the responsible party, especially with regard to security.

Note. Modified from YY/T 0316-2016, definition 2.1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1804-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1804-2021

$360.00