YY/T 0734.4-2016Washer-disinfectors - Part 4: Requirements and tests for washer-disinfectors employing thermal disinfection for non-invasive medical devices, etc. (English PDF)
清洗消毒器 第4部分:对非介入式等医疗器械进行湿热消毒的清洗消毒器要求和试验
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0734.4-2016 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
January 26, 2016
Implementation date
January 1, 2017
Scope
YY/T 0734.4-2016 is the English-translated version of 清洗消毒器 第4部分:对非介入式等医疗器械进行湿热消毒的清洗消毒器要求和试验.
YY/T 0734.4-2016 is the Chinese pharmaceutical industry standard for washer-disinfectors that clean and thermally disinfect non-invasive and other medical devices, reaching an A0 value of at least 60 and recording the critical process parameters automatically so that no separate recorder is needed.
It is the fourth part of the YY/T 0734 series and applies together with the general requirements of part 1, setting the particular requirements and the tests for such machines. Issued on 26 January 2016, it has applied since 1 January 2017.
Found what you need?
Document preview — YY/T 0734.4-2016
National Standard of the People's Republic of China
- ICS
- 11.080.10
- Classification
- C 47
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Terms and definitions
- 4 Requirements
- 5 Test methods
- 6 logo and instructions
- 7 Packaging, transportation, storage
Foreword
YY/T 0734 "cleaning sterilizer" is divided into five parts.
- Part 1. General requirements, terms and tests;
- Part 2. Requirements and tests for cleaning and disinfecting of heat and heat disinfection of surgical and anesthesia equipment;
- Part 3. Requirements and tests for cleaning and disinfection of waste heat disinfectants for human waste containers;
- Part 4. Requirements and tests for cleaning and disinfection of non - intrusive medical devices for damp heat disinfection;
- Part 5. Requirements and tests for cleaning and disinfecting chemical disinfection of medical devices such as non-invasive and non-invasive medical devices. This section is part 4 of YY/T 0734.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section is the same as ISO 15883-6.:2011 "Cleaning Sterilizer Part 6. For non-intrusive, non-critical medical devices and medical equipment Line wet heat disinfection of the cleaning and disinfection requirements and test "(English version) of the consistency is not equivalent. The main differences between this section and ISO 15883-6.:2011 are.
--- adjust the standard structure;
- Added the contents of Chapters 6 and 7 of this section and supplemented some of the test methods;
--- Deleted terms with Part 2 (such as cleaning temperature, cleaning temperature range, etc.) and so on;
--- Appendix A relating to inspection rules is deleted.
1 Scope
This part of YY/T 0734 specifies the special requirements for cleaning and disinfecting non-intrusive and other medical devices. this Class cleaning sterilizers ensure that the level of disinfection is maintained by cleaning and moist heat sterilization (A0 value is not less than 60). At the same time, the cleaning process is critical Automatic recording of process parameters does not require a separate recording system.
This part requires the use of the general requirements specified in YY/T 0734.1-2009.
This part of the required cleaning disinfection for non-invasive (ie, non-penetrating skin or non-contact mucosal surface) and other medical devices Cleaning and disinfection.
The requirements of this section do not apply to cleaning sterols as defined in the range YY/T 0734.2, YY/T 0734.3, nor are they applicable to endoscopes Cleaning and disinfection, the medical equipment specified in this section does not include power equipment, luminal instruments and other interventional devices.
NOTE: Damp heat disinfection of the load can be achieved by hot water rinsing, exposure to steam or a combination of both.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
Cleaning and disinfecting - Part 1. General requirements, Terminology definitions and tests - YY/T 0734.1-2009
YY/T 0734.2 Cleaning and disinfecting equipment - Part 2. Cleaning and disinfection requirements for heat and disinfection of surgical and anesthesia equipment And test
YY/T 0734.3 Cleaning and disinfecting equipment - Part 3. Cleaning and disinfecting requirements for hygienic disinfection of human waste containers test ISO /T S15883-5 Cleaning and disinfecting - Part 5. Test contaminants and test methods for the verification of cleaning effects (Washer-disin-fectors-Part 5. Testsoilsandmethodsfordemonstratingcleaningefficacy)
3 Terms and definitions YY/T
Definitions and the following terms and definitions apply to this document.
3.1 Non-invasive instruments
non-invasivedevice Through the human body cavity or body surface, can not penetrate the body of the device.
4 Requirements
4.1 Overview
4.1.1 Shall comply with the requirements of YY/T 0734.1-2009, except that 4.4.2,4.7,4.13,4.15 in YY/T 0734.1-2009 shall not apply
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- YY/T 0734.2Washer-disinfectors - Part 2: Washer-disinfectors employing thermal disinfection for surgical instruments, anaestetic equipment, etc.—Requirements and tests
- YY/T 0734.3Washer-disinfector - Part 3: Washer-disinfectors employing thermal disinfection for human waste containers—Requirements and tests
Similar standards
How to Download YY/T 0734.4-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0734.2-2009 — Washer-disinfectors - Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, etc.
YY/T 0734.2-2018 — Washer-disinfectors - Part 2: Washer-disinfectors employing thermal disinfection for surgical instruments, anaestetic equipment, etc.—Requirements and tests
YY/T 0734.3-2009 — Washer-disinfector - Part 3: Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers
Secure payment via Stripe
Payments accepted
YY/T 0734.4-2016
$95.00