YY/T 0708-2009Medical electrical equipment - Part 1-4: General requirements for safety - Collateral standard: Programmable electrical medical systems (English PDF)
医用电气设备 第1-4部分:安全通用要求:可编程医用电气系统
This is a limited preview
Buy now to download the full PDF (37 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0708-2009 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
November 25, 2009
Implementation date
December 1, 2010
Scope
YY/T 0708-2009 is the English-translated version of 医用电气设备 第1-4部分:安全通用要求:可编程医用电气系统.
YY/T 0708-2009 is the Chinese pharmaceutical industry standard that sets the general requirements for the safety of programmable electrical medical systems.
It is part 1-4 of the series, a collateral standard to the general standard, and it covers the development life cycle of the programmable part of such a system, the risk management that accompanies it, the requirements for the specification, the design and the verification of the software and for the documentation kept, a requirement of a particular standard taking priority over the corresponding requirement here. Issued on 25 November 2009, it has applied since 1 December 2010.
Found what you need?
Document preview — YY/T 0708-2009
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- Introduction4
- 1 Scope of application, object and relationship to other standards5
- 1.201 Scope5
- 1.202 Object5
- 1.203 Relationship to other standards6
- 2.201 Terminology and definitions7
- 2.202 Degrees of requirements and miscellaneous terms9
- 6 Identification, marking and documents9
- 6.8 ACCOMPANYING DOCUMENTS9
- 52 Abnormal operation and fault conditions10
- 52.201 Documentation10
- 52.202 RISK management plan10
- 52.203 DEVELOPMENT LIFE-CYCLE11
- 52.204 RISK management process14
- 52.205 Qualification of personnel16
- 52.206 Requirement specification17
- 52.207 Architecture17
- 52.208 Design and implementation18
- 52.209 VERIFICATION18
- 52.210 VALIDATION19
- 52.211 Modification19
- 52.212 Assessment20
- Annex AAA (Normative) Terminology - Index of defined terms21
- Annex BBB (Informative) Rationale22
- Annex CCC (Informative) RISK concepts25
- Annex DDD (Informative) DEVELOPMENT LIFE-CYCLE32
- Annex EEE (Informative) Examples for PEMS/PESS structures35
- Annex FFF (Informative) Bibliography37
Foreword
This Collateral Standard is identical to IEC 60601-1-4:2000 "Medical electrical equipment - Part 1-4.General requirements for safety - Collateral Standard. Programmable electrical medical systems".
This Collateral Standard is a Collateral Standard of the General Standard GB 9706.1-2007 "Medical electrical equipment - Part 1: General requirements for safety" (IEC 60601-1:1988, IDT).
Annex AAA of this Collateral Standard is a normative annex. Annex BBB, annex CCC, annex DDD, annex EEE, annex FFF are all informative annexes.
1 Scope of application, object and relationship to other standards
A requirement in a Particular Standard takes priority over the corresponding requirement in this Collateral Standard.
2.201 Terminology and definitions
For the purpose of this Collateral Standard, the following terminology and definitions apply. In this Collateral Standard, terms printed in CAPITALS are used in accordance with their definitions in the General Standard, GB 9706.15, this Collateral Standard or IEC 60788:1984.
6 Identification, marking and documents
Information pertaining to any specific EQUIPMENT that software is intended to be used in conjunction with, and a means by which the MANUFACTURER can be contacted, can be located on the package or in the INSTRUCTIONS FOR USE so that it is available to the USER independently of the software operation.
52 Abnormal operation and fault conditions
The leader of the team carrying out the VALIDATION shall be independent of the design team. Compliance is checked by inspection of the RISK MANAGEMENT FILE. Annex AAA (Normative)
Terminology - Index of defined terms With current technology there is no definitive way to determine what processes are appropriate for any particular case. Users of the standard should use their best judgement, based on what is reasonably practicable and taking account of the ALARP principle. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 37 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0708-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 0708-2009
$225.00