YY/T 9706.110-2021Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance - Collateral standard: Requirements for the development of physiologic closed-loop controllers (English PDF)

医用电气设备 第1-10部分:基本安全和基本性能的通用要求 并列标准:生理闭环控制器开发要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (23 pages)

Need quotation for your management?

Get a formal quotation for YY/T 9706.110-2021 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

March 9, 2021

Implementation date

May 1, 2023

Scope

YY/T 9706.110-2021 is the English-translated version of 医用电气设备 第1-10部分:基本安全和基本性能的通用要求 并列标准:生理闭环控制器开发要求.

YY/T 9706.110-2021 is the Chinese collateral standard on the development of physiologic closed-loop controllers in medical electrical equipment, the controllers that measure a physiological variable and adjust the therapy themselves.

It is part 1-10 of the YY/T 9706 series, sits alongside the general standard GB 9706.1-2020, and is an adoption of IEC 60601-1-10:2007 with its 2013 amendment, with the international references replaced by the Chinese ones.

It sets the general requirements, the identification, marking and documentation of the equipment, the accuracy of controllers and instruments and protection against hazardous output, the requirements on programmable electrical medical systems, and then the development requirements for the closed-loop controller itself.

Its informative appendices give the rationale, a description of the dynamic performance of such controllers and guidance on marking. Issued on 9 March 2021, it has applied since 1 May 2023.

Found what you need?

Document preview — YY/T 9706.110-2021

National Standard of the People's Republic of China

Classification
C 30

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope, purpose and related standards
  • 2 Normative references
  • 3 Terms and definitions
  • 4 *General requirements
  • 5 ME equipment identification, marking and documentation
  • 6 Accuracy of controllers and instruments and protection of dangerous outputs
  • 7 *Programmable Medical Electrical System (PEMS)
  • 8 Requirements for the development of Physiological Closed Loop Controller (PCLC)
  • Appendix A (informative appendix) General guidance and principle explanation
  • Appendix B (informative appendix) Description of PCLCS dynamic performance
  • Appendix C (informative appendix) Guidelines for marking and marking requirements for ME equipment and ME systems
  • References

Foreword

YY/T 9706 "Medical Electrical Equipment" series standards are divided into two parts.

---Part 1: General and parallel requirements;

---Part 2: Special requirements. This part is part 1-10 of YY/T 9706.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

The revision of this part adopts IEC 60601-1-10:2007 A1.2013 "Medical Electrical Equipment Part 1-10.Basic Safety and Basic Parallel standards for general performance requirements. Physiological closed-loop controller development requirements" (English version).

Compared with IEC 60601-1-10:2007 A1.2013, the main technical changes in this part are as follows except for editorial changes.

---Regarding normative reference documents, this section has made adjustments with technical differences, and has used my country's technical conditions and adjustments.

The situation is collectively reflected in Chapter 2 "Normative Reference Documents", and the specific adjustments are as follows.

- Replace IEC 60601-1:2012 with GB 9706.1-2020, which is modified to adopt international standards;

- Replace IEC 60601-1-6:2013 with YY/T 9706.106 which is modified to adopt international standards;

- Replace IEC 60601-1-8:2012 with YY 9706.108-2021 which is modified to adopt international standards;

- Replace IEC 62366:2007 with YY/T 1474 which is modified to adopt international standards;

- Replace ISO 14971 with YY/T 0316 which is equivalent to adopting international standards;

---Some typesetting formats have been modified in accordance with GB/T 1.1;

---In order to facilitate the understanding of the original standard, the standard referenced in the appendix (informative appendix) retains the original standard number;

---The index is deleted.

1 Scope, purpose and related standards

1.1 *Scope This part of YY/T 9706 specifies that in medical electrical equipment and medical electrical systems (hereinafter referred to as ME equipment and ME system), The development of a physiological closed-loop controller (PCLC) used to control physiological variables as part of a physiological closed-loop control system (PCLCS) (analysis, Design, verification and validation) requirements.

Note. Physiological variables can be human chemical components (such as electrolytes, blood sugar), physical properties (such as patient temperature, electrophysiological phenomena, hemodynamics) or drugs concentration.

This section applies to the basic safety and basic performance of ME equipment and ME systems.

This section applies to various types of PCLC, such as linear and non-linear, adaptive, fuzzy, neural network, etc. The content of this section does not include.

---Additional mechanical requirements; or ---Additional electrical requirements.

This part is applicable to closed-loop controllers (see Figure 1). The output variables of the controller are set and related to the reference variables to adjust (that is, change the Change or maintain) the measured physiological variables.

This section does not apply to closed-loop controllers that use feedback data from non-patient measurements to maintain physical or chemical variables.

Note. The chapters and articles with an asterisk (*) in this section have relevant principles in Appendix A.

1.2 Purpose

Prescribe general requirements beyond the requirements of general standards and serve as the basis for specific standards.

1.3 Related standards

1.3.1 GB 9706.1

For ME equipment and ME systems, this section is a supplement to GB 9706.1.

When referring to GB 9706.1 or this part alone or in combination, the following conventions are used.

--- "General Standard" refers to a separate GB 9706.1;

--- "This Part" refers to a separate YY/T 9706.110 (IEC 60601-1-10);

--- "This standard" refers to the combination of the general standard and this part.

1.3.2 Specific standards

The requirements of the specific standards take precedence over the corresponding requirements in this section.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.

Similar standards

How to Download YY/T 9706.110-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
23 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 9706.110-2021

$390.00