YY/T 0693-2008Standard guide for characterization and presentation of the dimensional attributes of vascular stents (English PDF)
血管支架尺寸特性的表征
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0693-2008 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
October 17, 2008
Implementation date
January 1, 2010
Scope
YY/T 0693-2008 is the English-translated version of 血管支架尺寸特性的表征.
YY/T 0693-2008 is the Chinese pharmaceutical industry guide, a modified adoption of ASTM F2081-06, on how to characterize and present the dimensions of vascular stents.
It identifies the size attributes linked to clinical performance and effectiveness, recommends methods for measuring them, and covers the stent delivery system as packaged together with its specific labelling.
All attributes are bench measurements made in vitro, and material and functional properties are left out. The methods target metal and alloy balloon-expandable and self-expanding stents; coated, polymer and biodegradable stents are not specifically addressed but not excluded, and the methods may also serve for oesophageal or biliary stents.
Endovascular grafts and angioplasty balloon catheters sold separately fall outside it, the latter being covered by YY 0285.1 and YY 0285.4. Issued on 17 October 2008, it has applied since 1 January 2010.
Found what you need?
Document preview — YY/T 0693-2008
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C 35
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
The revised standard ASTMF2081-06 "stent dimensions are characterized in" adoption.
No technical differences between this standard and ASTMF2081-06 compared to only a small part of the editorial changes and preparation instructions in this standard Listed. Appendix A of this standard is an informative annex.
1 Scope
1.1 This includes the identification and detection method recommended clinical performance and effectiveness associated vascular prosthesis size property. This standard also Including stent delivery system during packaging and special identification.
1.2 This standard only points out the dimensional characteristics of the stent. Here it does not indicate the material properties and functional properties of the stent. Described in this standard All dimensions characteristics are measured in vitro test ( "bench") feature. Patient due to various factors, such as vascular compliance, the actual in vivo test Test characteristics may have minor differences.
1.3 This standard includes for metal and alloy balloon-expandable stents and self-expanding stents is the recommended method. This standard is not specifically Do not explain the stent or a polymer coated stent with a biodegradable scaffold or proprietary property, although the standard does not exclude for the above products.
1.4 Although this standard is not specified, but for non-vascular stent placement location, such as esophageal stent or biliary stent, you can still use this Lane include a method to characterize. Also, the standard does not include endovascular grafts or commonly used to treat an aneurysm or peripheral vascular damage or The recommended way to provide other vascular access catheter device, but some of the information covered by this standard may also be used in these devices.
1.5 standard does not include a description as angioplasty catheters sold separately form shaped balloon catheter, the catheter can be used even if some of them No delivery conveyor system is not mounting bracket. Require angioplasty catheters see standard YY 0285.1 and YY 0285.4.
1.6 The main purpose of the standard is to promote the consistency of the label to facilitate clinical users of devices to choose from. The use of international standards Units or derived units, users are accustomed to selected units will be given in the form of brackets.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
YY 0285.1 Disposable Sterile intravascular catheters - Part 1. General requirements (YY 0285.1-2004, ISO 10555-1. 1995, IDT)
YY 0285.4 sterile single-use intravascular catheters - Part 4. Balloon dilatation catheters (YY 0285.4-1999, idt ISO 10555-4:1996)
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1 Balloon-expandable stent
At the treatment site by a balloon catheter stent expansion. By balloon dilation, stent shape is changed permanently so that after shrinkage of the balloon Holder should maintain expansion.
3.2 Bridge
The connection portion of the stent between radial support. Compared with the pillars, the bridge may have unique design features to enhance flexibility and reduce longitudinal retraction.
3.3 Crimping
By compressing the stent onto the balloon and to ensure that the bracket on the conveyor system. Sold in the form of non-preloaded stent prior to use must be temporary Bed of medical personnel hand crimp.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0693-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY 0285.1-1999 — Sterile, single-use intravascular catheters - Part 1: General requirements
YY 0285.1-2004 — Sterile, single-use intravascular catheters - Part 1: General requirements
YY 0285.1-2017 — Intravascular catheters—Sterile and single-use catheters - Part 1: General requirements
Secure payment via Stripe
Payments accepted
YY/T 0693-2008
$145.00