Scope

YY/T 0593-2022 is the English-translated version of 超声经颅多普勒血流分析仪.

YY/T 0593-2022 is the Chinese pharmaceutical industry standard for the transcranial Doppler ultrasound system, the instrument that measures blood flow velocity in the arteries at the base of the brain through the skull.

It gives the terms and definitions, the classification of the products, the requirements and the test methods, covering the probes and their frequencies, the sensitivity and the depth of detection, the accuracy of the velocity measurement and of the sample volume position, the spectral display and the audio output, together with safety and electromagnetic compatibility by reference to the general standards.

It replaces YY/T 0593-2015, was issued on 18 May 2022 and has applied since 1 June 2023.

Found what you need?

Document preview — YY/T 0593-2022

National Standard of the People's Republic of China

Replacing
YY/T 0593-2015

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative References5
  • 3 Terms and Definitions5
  • 4 Product Classification6
  • 5 Requirements6
  • 6 Test Methods9
  • Appendix A (informative) Measurement of Blood Flow Velocity Range Using Frequency Shift Simulation Method13

1 Scope

This document specifies the terms and definitions, product classification, requirements and test methods for transcranial doppler ultrasound system.

This document is applicable to transcranial doppler ultrasound system (hereinafter referred to as TCD instrument).

2 Normative References

The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB 9706.1 Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance

GB 9706.237 Medical Electrical Equipment - Part 2-37: Particular Requirements for the Basic Safety and Essential Performance of Ultrasonic Medical Diagnostic and Monitoring Equipment

GB/T 14710 Environmental Requirement and Test Methods for Medical Electrical Equipment

YY/T 0458 Technical Requirements for Ultrasonically Blood-mimicking Doppler Phantom

YY/T 0704 Ultrasonics - Pulsed Doppler Diagnostic System - Test Procedures to Determine Performance

YY/T 0705 Ultrasonics - Continuous-wave Doppler Systems - Test Procedures

YY/T 1142 Methods of Measuring the Frequency of Medical Ultrasonic Equipment and Probe

YY/T 1420 Environmental Requirement and Test Methods for Medical Ultrasonic Equipment

3 Terms and Definitions

What is defined in GB 9706.237, YY/T 0458, YY/T 0704 and YY/T 0705, and the following terms and definitions are applicable to this document.

3.1 Transcranial doppler ultrasound system

An equipment that utilizes the principle of ultrasound doppler to measure the blood flow in intracranial blood vessels through the skull.

NOTE: by configuring the corresponding probe, it can also be used for blood flow measurement in the extracranial neck and peripheral blood vessels.

3.2 Nominal acoustic working frequency

Ultrasonic working frequency published by the designer or manufacturer.

NOTE: the unit is megahertz (MHz).

3.3 Sample volume

When pulsed doppler is used to measure the blood flow velocity, the sampling area of the measurement site.

NOTE 1: the unit is millimeters (mm).

NOTE 2: the width of the sample volume of the TCD instrument cannot be adjusted, and the length of the sample volume can only be adjusted by controlling the duration of the pulse wave.

4 Product Classification

4.1 In accordance with the number of channels, it can be classified into:

a) Single-channel TCD instrument: an equipment with only one probe channel activated at the same time and displaying the corresponding spectrum signal;

b) Dual-channel (multi-channel) TCD instrument: an equipment with two (or more) probe channels activated at the same time and displaying the corresponding spectrum signal.

4.2 In accordance with the number of depths that can be obtained through one channel, it can be classified into:

a) Single-depth TCD instrument: an equipment that can obtain a doppler spectrum signal at one depth from one probe channel;

b) Dual-depth (multi-depth) TCD instrument: an equipment that can simultaneously obtain doppler spectrum signals at two depths (or multiple depths) from one probe channel.

5 Requirements

5.1 Ultrasonic Working Frequency

The deviation between the ultrasonic working frequency and the nominal ultrasonic frequency published by the manufacturer shall be not greater than ± 10%.

50 Hz, 100 Hz, 200 Hz and 400 Hz;

d) Spectrum analysis function;

e) Spectrum resolution setting;

f) Range gating setting;

g) Sampling area setting;

h) Receive gain adjustment;

i) Baseline movement;

j) Scale setting;

k) Parameter measurement: in the frozen state of the atlas, velocity, acceleration, vascular pulsation index (PI) and vascular resistance index (RI) can be measured;

l) The range gating parameters of each channel of the dual-channel TCD instrument can be independently adjusted.

5.8 Appearance and Structure

5.8.1 The outer casing of the TCD instrument shall have no obvious mechanical damage, rust and other defects, and the texts and logos on the panel shall be clearly visible.

5.8.2 The plastic parts of the TCD instrument shall be free from blistering, cracking, deformation and overflow of filling material.

5.8.3 The operation and adjustment mechanism of the TCD instrument shall be flexible and reliable, and the fasteners shall not be loose.

5.9 Safety

The TCD instrument shall comply with the requirements of GB 9706.1 and GB 9706.237.

5.10 Environmental Test

The environmental test requirements of the TCD instrument shall comply with the manufacturer's stipulations in accordance with the climatic environment test group I and the mechanical environment test group II in GB/T 14710. The test time, recovery time and inspection items shall comply with the supplementary stipulations in Table 2. The special requirements and methods of environmental test can be implemented in accordance with the principles and stipulations of YY/T 1420.

It is recommended use blood-mimicking phantoms and string-type test pieces. The requirements for blood-mimicking phantoms can take YY/T 0458 as a reference; the requirements for string-type test pieces can take YY/T 0705 as a reference.

6 Test Methods

6.2 Ultrasonic Working Frequency

In accordance with the method specified in YY/T 1142, carry out the test, which shall comply with the requirements of 5.1.

6.3 Flow Velocity Measurement Range and Error

In accordance with the interval of the flow velocity measurement range, different test methods can be adopted. When the set value of the measured flow velocity is within the range of Table 1, adopt the blood-mimicking phantoms or string-type test pieces for the test. When the set value of the measured flow velocity exceeds the measuring range of the blood-mimicking phantoms or string-type test pieces, the method in Appendix A can be used for the test.

When blood-mimicking phantoms or string-type test pieces are used for the test, follow the instructions for use of the blood-mimicking phantoms or string-type test pieces. The settings of the TCD instrument under test are as follows:

a) Blood vessel selection, filtering, sound power and receive gain are adjusted to the optimal position;

b) The working distance and sample volume are set in accordance with the stipulations of Table 1;

c) It is recommended to select 30°, 45° or 60° for the included angle between the doppler sound beam axis (generally, the axis of the probe handle) and the target movement direction. When calculating the displayed flow velocity error, in addition to the actual angle mentioned above, it shall also be considered that the doppler angle of the TCD instrument is set to 0°;

d) When testing the flow velocity measurement range, the flow velocity of the phantoms is respectively set at the maximum value and minimum value of the flow velocity measurement range of the TCD instrument under test; when the flow velocity measurement range of the TCD instrument exceeds the measuring range of the blood-mimicking phantoms or string-type test pieces, the method in Appendix A can be used for the test;

e) When testing the flow velocity measurement error, the flow velocity of the phantoms is respectively set at 1/3 and 2/3 of the flow velocity measurement range of the TCD instrument under test.

The test results shall comply with the requirements of 5.2 and 5.3.

6.4 Working Distance

Adopt the blood-mimicking phantoms or string-type test pieces, at the nominal maximum working distance and minimum working distance, use a TCD instrument to detect the target.

Check whether the displayed frequency spectrum is normal, which shall comply with the requirements of 5.4.

6.5 Range Gating Error

The sample volume of the TCD instrument is recommended to be set to 4 mm and 20 mm, and other statuses are set to the optimum. Adopt the ultrasonically blood-mimicking doppler phantom. It is recommended that the distance between the tested point of the blood-mimicking phantom and the probe be set at 50 mm. Set the range gating of the TCD instrument also to 50 mm and use the TCD instrument to detect the tested point of the blood-mimicking phantom. At this moment, the TCD instrument shall have obvious doppler spectrum signals. Increase or decrease the set value of the range gating, find the point with the strongest signal to read the range gating, or find the position with the same signal strength in the upward and downward directions. Record the range gating set values in both directions and take the average value. The absolute value of the difference from the actual value (50 mm) is used as the range gating error of the two sample volumes of 4 mm and 20 mm, and the most unfavorable value shall comply with the requirements of 5.5.

A TCD instrument with M mode functions can use the M mode display window to accurately find the test signal. By selecting the strongest point of the signal band on the M mode display window, the range gating of this signal can be read.

6.6 Ultrasonic Output Power Adjustment

Successively adapt probes with different operating frequencies and operating modes to the TCD instrument, respectively observe their spectrum signal strengths when the output power is set to the relatively small and large values. There shall be corresponding changes, which shall comply with the requirements of 5.6.

6.7 Working Status and Function Settings

Operate in accordance with the stipulations of the instruction manual and verify by checking the screen display and working status, which shall comply with the requirements of 5.7.

6.8 Appearance and Structure

Conduct visual inspection and operation inspection, which shall comply with the requirements of 5.8.

6.9 Safety

Conduct the test in accordance with the stipulations of GB 9706.1 and GB 9706.237, which shall comply with the requirements of 5.9. […]

6.10 Environmental Test

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.

Referenced standards

Editions of YY/T 0593

EditionTitleRevisionStatus
YY/T 0593-2022Transcranial doppler ultrasound systemcurrent editionCurrent
YY/T 0593-2015Transcranial doppler ultrasound systemprevious editionSuperseded

This page sells the current edition, YY/T 0593-2022. Earlier editions are listed for reference only.

How to Download YY/T 0593-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
24 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0593-2022

$150.00