Valid

YY/T 0520-2009Titanium and titanium alloy dental implant attachments (English PDF)

钛及钛合金材质牙种植体附件

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0520-2009 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 30, 2009

Implementation date

June 1, 2011

Scope

YY/T 0520-2009 is the English-translated version of 钛及钛合金材质牙种植体附件.

YY/T 0520-2009 is the Chinese pharmaceutical industry standard for the dental implant attachments made of titanium and titanium alloys.

It sets the performance requirements for them and the corresponding test methods, covering the material and its composition, the dimensions and their tolerances, the fit and the strength of the connection to the implant, the fatigue behaviour, the surface finish and the marking. Issued on 30 December 2009, it has applied since 1 June 2011.

Found what you need?

Document preview — YY/T 0520-2009

National Standard of the People's Republic of China

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword3
  • Introduction4
  • 1 Scope5
  • 2 Normative references5
  • 3 Terms and definitions6
  • 4 Material7
  • 5 Requirements7
  • 6 Test method9
  • 7 Packaging, marking and instruction manual10
  • References13

Foreword

All the technical contents of this standard are recommended.

1 Scope

This standard specifies the performance requirements and corresponding test methods for the dental implant attachments of titanium and titanium alloys, as well as the packaging.

The dental implants in this standard refer to various ancillary components used in conjunction with dental implants to support the upper structure (prosthesis) of the implanted denture, including abutments and central screws. The dental implant attachments in this standard also include the cover screw, healing cap, and healing abutment which are used on the implant before assembling the upper structure. This standard does not cover the devices used for the upper structure which is made in the dental laboratory (e.g. transfer body, retention screw, connection ring, and upper structure, etc.).

2 Normative references

The provisions in following documents become the provisions of this Standard through reference in this Standard. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard; however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable.

For undated references, the latest edition of the referenced document applies.

GB/T 4698-1996 Methods for chemical analysis of sponge titanium, titanium and titanium alloys

GB/T 9937.1-2008 Dental vocabulary - Part 1. General and clinical terms (ISO 1942-1:1989, IDT)

GB/T 9937.2-2008 Dental vocabulary - Part 2. Dental material (ISO 1942-2:1989, IDT)

GB/T 13810-2007 Wrought titanium and titanium alloy for surgical implants

YY/T 0343-2002 Liquid penetrant inspection of metallic surgical implants (ISO 9583:1993, NEQ)

YY/T 0521-2009 Dentistry implants - Dynamic fatigue test for endosseous dental implants (ISO 14801. 2007, IDT)

Note: The abutment can be connected to the implant via a central screw, OR otherwise connected to the implant through embedding or other methods.

3 Terms and definitions

3.5 Central screw

A screw that penetrates the center of the abutment AND fastens the abutment onto the implant.

3.6 Cover screw, healing screw, closure screw

After the implant is implanted in the jaw, the cap structure above the implant is screwed in to avoid tissue growth. During secondary operation, the cover screw is taken out, AND the abutment is installed in place.

3.7 Healing cap/hygiene screw, hygiene cover screw, hygiene cap

Attachments which are temporarily installed onto the abutment end.

3.8 Healing abutment

A transitional abutment. In the soft tissue healing period after surgery, the healing abutment is attached to the implant, which helps the soft tissue to be shaped in accordance with the shape of the healing abutment AND then replaced by the abutment.

4 Material

It shall comply with GB/T 13810-2007 Wrought titanium and titanium alloy for surgical implants.

5 Requirements

5.1 Appearance

the tweezers to take all the implant attachments out from the beaker; USE the qualitative filter paper to filter the liquid in the beaker; AND there shall be no visible attachment on the filter paper.

6 Test method

6.7 Fatigue limits

MAKE test in accordance with YY/T 0521-2009, AND the test results shall comply with the provisions of clause 5.7.

6.8 Chemical composition

MAKE test in accordance with GB/T 4698-1996, AND the chemical composition shall comply with the provisions of clause 5.8.

6.9 Sterile

MAKE test in accordance with the Appendix XI H "Sterile test method" of the Pharmacopoeia of the People's Republic of China (Volume II), AND the test results shall comply with the provisions of clause 5.9.

6.10 Pyrogen

MAKE test in accordance with the Appendix XI H "Pyrogen test method" of the Pharmacopoeia of the People's Republic of China (Volume II), AND the test results shall comply with the provisions of clause 5.10.

7 Packaging, marking and instruction manual

7.1 Product marking

If the size and surface conditions of the dental implant attachment permit, under the preconditions of not affecting the use performance of the dental implant attachment, it shall make clear manufacturer marking, product batch (serial) number, and specification marking on an appropriate region at each dental implant attachment surface. However, if the size and surface conditions do not permit, it shall use the label or other methods to provide the information required, in order to ensure the traceability.

7.2 Labeling and packaging mark

The labeling and packaging mark of dental implant attachment shall include at least the following.

a) Product name, model, specification;

b) Manufacturer's name, address, and contact information; […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0520-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0520-2009