Valid

YY/T 0482-2022Magnetic resonance equipment for medical imaging—Determination of essential image quality parameters (English PDF)

医用磁共振成像设备 主要图像质量参数的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (70 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0482-2022 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

July 1, 2022

Implementation date

May 1, 2023

Scope

YY/T 0482-2022 is the English-translated version of 医用磁共振成像设备 主要图像质量参数的测定.

YY/T 0482-2022 is the Chinese pharmaceutical industry standard covering magnetic resonance equipment for medical imaging, Determination of essential image quality parameters.

It was issued on 1 July 2022 and has been in force since 1 May 2023, replacing YY/T 0482-2010. The document is under the responsibility of the National Medical Products Administration.

This page is published from the official record of the 2022 edition. The figures, limits and tables the standard contains are those of the document itself, delivered in full with the English translation.

Found what you need?

Document preview — YY/T 0482-2022

National Standard of the People's Republic of China

Replacing
YY/T 0482-2010

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions, symbols and abbreviated terms
  • 4 Procedures for the determination of the main image parameters
  • 4.1 General requirements of the measuring procedure
  • 4.2 Signal to noise ratio
  • 4.3 Uniformity
  • 4.4 Slice thickness of a two dimensional scan
  • 4.5 Two dimensional geometric distortion
  • 4.6 Spatial resolution
  • 4.7 Ghosting
  • 5 Stability test
  • 5.1 Purpose and principle
  • 5.2 Requirements for the test phantom
  • 5.3 Scanning characteristics
  • 5.4 Measuring procedure
  • 5.5 Data analysis, reporting of the results and tolerances
  • Annex A (normative) Alternative methods
  • Annex B (informative) Basic principles
  • Bibliography
  • Figure 1 Signal intensity profile in the inclined plate method
  • Figure 2 Correction of the rotation of the test phantom (the broken line shows the position of the opposite plate)
  • Figure 3 Example of a test phantom for a spherical specified region volume (two of the lines pass through the centre)
  • Figure 4 Example of a fiducial marker test phantom for a spherical specified region volume
  • Figure 5 Measurement of the radius
  • Figure 6 Periodic pattern
  • Figure 7 Image of the periodic pattern and position of the ROI for a coronal scan
  • Figure 8 Image of the periodic pattern and position of the ROI for transverse and sagittal scans
  • Figure 9 Sample image of the test phantom and of the ROI for the measurement of signal, ghost and noise

Document data

Chinese classification (CCS): C39.

Estimated length of the Chinese original: 76,740 words.

3 Terms, definitions, symbols and abbreviated terms

4 Procedures for the determination of the main image parameters

5 Stability test

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 70 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY/T 0482

EditionTitleRevisionStatus
YY/T 0482-2022Magnetic resonance equipment for medical imaging—Determination of essential image quality parameterscurrent editionCurrent
YY/T 0482-2010Magnetic resonance equipment for medical imaging—Determination of essential image quality parametersprevious editionSuperseded

This page sells the current edition, YY/T 0482-2022. Earlier editions are listed for reference only.

How to Download YY/T 0482-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
70 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0482-2022

$950.00