YY/T 0297-1997Clinical investigation of medical devices (English PDF)

医疗器械临床调查

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0297-1997 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

August 27, 1997

Implementation date

January 1, 1998

Scope

YY/T 0297-1997 is the English-translated version of 医疗器械临床调查.

YY/T 0297-1997 is the Chinese standard "Clinical investigation of medical devices".

Its scope clause reads: This standard a) is applicable to the clinical investigation in human subjects of those medical devices whose clinical performance needs assessment; b) specifies the requirements for the conduct of the clinical investigation and documentation on whether the medical device achieves the performance intended by the sponsor, determines any undesirable side effects under normal conditions of use and permits assessment of the acceptable risks relating to the intended performance of the device; c) provides the framework for systematic written procedures for the organization, design, implementation, data collection, documentation arid conduct of the clinical investigation. Its clauses include definitions.

Found what you need?

Document preview — YY/T 0297-1997

National Standard of the People's Republic of China

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword i
  • ISO foreword ii
  • 1 Scope
  • 2 Normative references
  • 3 Definitions
  • 4 Ethical considerations
  • 5 Basic requirements
  • 6 Methodology
  • 7 Presentation of results
  • Annex B (Informative) Rationale
  • Annex C (Informative) Flow chart for clinical investigation of medical devices

1 Scope

This standard a) is applicable to the clinical investigation in human subjects of those medical devices whose clinical performance needs assessment;

b) specifies the requirements for the conduct of the clinical investigation and documentation on whether the medical device achieves the performance intended by the sponsor, determines any undesirable side effects under normal conditions of use and permits assessment of the acceptable risks relating to the intended performance of the device;

c) provides the framework for systematic written procedures for the organization, design, implementation, data collection, documentation arid conduct of the clinical investigation.

2 Normative references

The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. At time of publication, the editions indicated were valid. All standards are subject to revision, and all parties using this standard are encouraged to investigate the possibility of applying the latest editions of the following standards.

World Medical Association's Declaration of Helsinki, Recommendations guiding physicians in biomedical research involving human subjects (see Annex A).

3 Definitions

For the purposes of this standard, the following definitions apply.

3.1 clinical investigation

any systematic study in subjects undertaken to verify the performance of a specific device under normal conditions of intended use

3.2 medical device

any instrument, apparatus, appliance, material or other article, whether used alone or in combination, including the software necessary for its proper application, intended by the manufacturer to be used for human beings for the purpose of:

——diagnosis, prevention, monitoring, treatment or alleviation of disease;

——diagnosis, monitoring, treatment, alleviation or compensation for an injury or handicap;

——investigation, replacement or modification of the anatomy or of a physiological process;

——control of conception;

and which does not achieve its principal intended action in or on the human body by pharmacological, immunological or metabolic means, but which may be assisted in its function by such means.

3.3 device (intended for clinical investigation)

any medical device intended for use by an appropriately qualified practitioner when conducting clinical investigations in an adequate clinical environment

3.4 clinical performance

effects achieved by a device in relation to its intended use, when correctly applied to appropriate subjects

3.5 clinical investigation plan

principal document which includes detailed information on the rationale, including risk versus benefit analysis, objectives, design and proposed analyses, methodology and conduct of the clinical investigation […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0297-1997

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0297-1997

$175.00