YY/T 0084.2-2009Strength calculation and relevant regulations of primary pressure containing parts for rectangular pressure steam-heated sterilizer (English PDF)
矩形压力蒸汽灭菌器主要受压元件强度计算及其有关规定
This is a limited preview
Buy now to download the full PDF (23 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0084.2-2009 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 16, 2009
Implementation date
December 1, 2010
Scope
YY/T 0084.2-2009 is the English-translated version of 矩形压力蒸汽灭菌器主要受压元件强度计算及其有关规定.
YY/T 0084.2-2009 is the Chinese pharmaceutical industry standard that fixes the strength calculation of the primary pressure containing parts of a rectangular steam-heated sterilizer, that is of the jacketed rectangular sterilizer, together with the related provisions, where these are not covered by the corresponding standards.
It is the second part of the YY/T 0084 series and sets out the design conditions, the formulae and the allowable stresses on which the calculation rests. Issued on 16 June 2009, it has applied since 1 December 2010.
Found what you need?
Document preview — YY/T 0084.2-2009
National Standard of the People's Republic of China
- ICS
- 11.080.99
- Classification
- C 47
- Replacing
- YY/T 0084.2-1992
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Materials
- 5 sterilizer housing
- 7 rectangular door structure and design calculation
- 8 bolt and door stop computing
- 9 support bolt hole calculation
- 10 computing center screw
Foreword
YY/T 0084 is divided into two parts.
--- Round Pressure Steam Sterilizer main pressure parts strength calculation and the relevant regulations;
--- Rectangular Pressure Steam Sterilizer main pressure parts strength calculation and the relevant regulations. This section YY/T Section 20084 of.
This section instead of YY/T 0084.2-1992 "Rectangular Pressure Steam Sterilizer main pressure parts strength calculation and the relevant provisions." Section compared with YY/T 0084.2-1992 The main changes are as follows.
--- This section of the basic symbols, terminology, definitions, selection of materials according to GB 150-1998, "Pressure Vessel Safety Technical Supervision Regulation Cheng "requirement;
--- Part of the scope of application has been modified to increase the limit cross-sectional dimension;
--- Sterilizer body design.
1) according to GB 150 model, an increase of "symbols" section;
2) The main structure. an increase in the form of the main structure, the new increase in the form of the inner shell, the shell and ribs were calculated;
--- After the rectangular head Calculation of additional bracing plate form was calculated;
--- Rectangular door calculate the new structure increases, according to a new increase in the form of a calculation;
--- Bolt calculation.
1) This part of the name to "bolt and door stop computing";
2) newly added in the form of cogs connecting structure, according to the newly added calculated;
--- Support bolt hole calculation keep this section;
--- Computing center screw retention of this section.
1 Scope
YY/T 0084 provisions of this part of the strong rectangular jacketed pressure steam sterilizer (hereinafter referred to as sterilization) main pressure components Calculation and the relevant provisions of this Part were not specified by the corresponding standards.
This section applies to the design pressure is less than 0.4MPa, the sterilization chamber volume of not more than 6m³, the sterilization chamber cross-sectional area of not more than 1.2m² Under vented or pre-vacuum pressure steam sterilizer.
2 Normative references
The following documents contain provisions which, through reference YY/T 0084 to the present, constitute provisions of this section. For dated references, All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encourage an agreement under this section Parties to study the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB 150-1998 Steel Pressure Vessels
GB 4793.4-2001 measurement, control and laboratory use electrical safety laboratory equipment used in the processing of medical materials autoclave Particular requirements (IEC 61010-2-041:1995, IDT)
JB/T 4734-2002 welded aluminum container
JB/T 4755-2006 Copper Pressure Vessels
YY 0154 pressure steam sterilization equipment with a spring-loaded safety valve Pressure Vessel Safety Technology Supervision 1999
3 Terms and Definitions
The following terms and definitions apply YY/T 0084 of this section.
3.1 Design pressure means
the maximum pressure setting sterilizer top of the container, together with the corresponding design temperature as the design load condition, its value is not Lower than the operating pressure.
3.2 Calculation pressure
Calculation means at a pressure corresponding to the design temperature, the pressure used to determine the thickness of the component, including the static pressure liquid column. When the element is exposed
When the liquid column static pressure is less than 5% of the design pressure is negligible.
3.3 Design temperature
Design temperature sterilizer means under normal working conditions, the temperature of the metal elements is set (in the average temperature of the metal section member). Design temperature design pressure together as the design load conditions.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 4793.4-2001Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 4: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
- JB/T 4734-2002Aluminium welded vessels
- JB/T 4755-2006Copper pressure vessels
- YY 0154Spring full lift safety valves on pressure steam sterilizer
GB 150-1998
Similar standards
Editions of YY/T 0084.2
| Edition | Title | Revision | Status |
|---|---|---|---|
| YY/T 0084.2-2009 | Strength calculation and relevant regulations of primary pressure containing parts for rectangular pressure steam-heated sterilizer | current edition | Current |
| YY/T 0084.2-1992 | Strength calculation and relevant regulations of primary pressure containing parts for rectangular pressure steam-heated sterilizer | previous edition | Superseded |
This page sells the current edition, YY/T 0084.2-2009. Earlier editions are listed for reference only.
How to Download YY/T 0084.2-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JB/T 4734-2002 — Aluminium welded vessels
JB/T 4755-2006 — Copper pressure vessels
YY 0154-1994 — Spring-type safety valves for pressure steam sterilization equipment