YY 1040.2-2008Anaesthetic and respiratory equipment - Conical connectors - Part 2: Screw-threaded weight-bearing connectors (English PDF)
麻醉和呼吸设备 圆锥接头 第2部分:螺纹承重接头
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for YY 1040.2-2008 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
October 17, 2008
Implementation date
June 1, 2010
Scope
YY 1040.2-2008 is the English-translated version of 麻醉和呼吸设备 圆锥接头 第2部分:螺纹承重接头.
YY 1040.2-2008 is the Chinese pharmaceutical industry standard for the screw-threaded weight-bearing conical connectors used in inhalational anaesthesia equipment and in ventilators, the connectors that carry the weight of an accessory.
It is the second part of the YY 1040 series and sets the requirements for them, covering the dimensions of the cone and of the thread and their tolerances, the gauging, the strength of the connection and the force it must bear, the leakage and the marking. Issued on 17 October 2008, it has applied since 1 June 2010.
Found what you need?
Document preview — YY 1040.2-2008
National Standard of the People's Republic of China
- ICS
- 11.040.10
- Classification
- C 46
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Design
Foreword
YY 1040 "Anaesthetic and respiratory equipment cone joint," consists of the following components.
--- Part 1. Cones and sockets;
--- Part 2. threaded bearing joints. This is Part 2 YY 1040 of.
This section identical with the international standard ISO 5356-2:2006 "anesthesia and respiratory equipment - Conical fittings - Part 2. load-bearing thread connection head".
This part of ISO 5356-2:2006 as compared to the major differences are as follows.
--- ISO 5356-2:2006 Introduction The introduction of this standard conversion, delete ISO 5356-2:2006 Foreword;
--- ISO 5356-2. ISO 2006 international standard referenced, there is a corresponding been translated into national standards and industry standards, in order to lead this part Use these national standards and industry standards as the norm; now no correspondence has been adopted as national standards and industry standards, places cited With international standards as ISO standard use.
Introduction
Although the conical fitting YY 1040.1-2003 described can be used to connect the light breathing attachment, however, support for heavy or fragile Accessories need to be more robust joint. These factors include the joint design strength, simple, easy sterilization, easy connection and removal by hand.
These fittings should also be compatible with the requirements of the joint accord YY 1040.1, and, although prior to use to check whether the system is installed correctly Is the user's responsibility, these joints should also try to avoid the possibility of accidental wrong connection.
Thread the load-bearing joints YY 1040 described in this section may be used for attachment in the respiratory system and the common gas outlet.
1 Scope
YY 1040 This section specifies requirements for inhalation anesthesia equipment and ventilators bearing cone threaded connectors, these connectors Used heavy equipment attachments.
2 Normative references
The following documents contain provisions which, through reference YY 1040 of this section and become part of the standard terms and conditions. For dated references Documents, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Research into whether the parties to the agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 9145-2003 common thread moderate accuracy, limit the size of the preferred series (ISO 965-2:1998, MOD)
YY 1040.1-2003 anesthesia and respiratory equipment - Conical fittings - Part 1. Cones and sockets (ISO 5356-1:1996, IDT)
3 Terms and Definitions
The following terms and definitions apply to this part YY 1040.
3.1 Anaesthetic gas delivery device
For dispensing and delivery of anesthetic gas and steam into the ventilation system of the device for delivery to the patient.
Note: According to GB/T 4999-2003 2.1.1 defined rewritten.
3.2 Improve the composition or component of a ventilation system
Note: According to GB/T 4999-2003 4.1.6 defined rewritten.
3.3 Breathing system
During ventilation in any form, in contact with the patient's respiratory tract, for continuously or intermittently transporting gas passage.
1) In some cases, especially in the breathing machine, the port may be inside the device should not be installed as the interfaces of the ventilator housing elsewhere Confused.
Note 1. In fact, the ventilation system typically extends from.
a) mixing the gas supply port 1), such as the common gas outlet anesthesia machine.
b) the circulatory system of the fresh gas inlet, such as ventilators, T-tubes.
c) a manual respirator fresh gas inlet.
Note 2. The ventilation system is usually extended to the gas mixture from the open end of the APL valve, T-shaped tube until the outlet air or gas purification system.
Note 3. connected to the gas purification system dedicated gas path can not be regarded as part of the ventilation system.
Note 4. According to GB/T 4999-2003 4.1.1 defined rewritten.
4 Design
Thread size bearing joint assembly shown in Figure 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- YY 0600.5-2011Lung ventilators for medical use—Particular requirements for basic safety and essential performance - Part 5: Gas-powered emergency resuscitators
- YY 0671.2-2011Sleep apnoea breathing therapy - Part 2: Masks and application accessories
- YY/T 0735.2-2010Anaesthetic and respiratory equipment - Heat and moisture exchangers (HMEs) for humidifying respired gases in humans - Part 2: HMEs for use with tracheostomised patients
- YY 0635.2-2009Inhalational anaesthesia systems - Part 2: Anaesthetic gas scavenging systems transfer and receiving systems
- YY 0635.4-2009Inhalational anaesthesia systems - Part 4: Requirements for anaesthetic ventilators
- YY/T 0735.1-2009Anaesthetic and respiratory equipment - Heat and moisture exchangers (HMEs) for humidifying respired gases in humans - Part 1: HMEs for use with minimum tidal volumes of 250 mL
Similar standards
How to Download YY 1040.2-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 9145-2003 — General purpose metric screw threads -- Limits of sizes for the screw threads of medium quality and preferable plan
YY 1040.1-2003 — Anaesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets
YY 0017-2026 — Implants for osteosynthesis - Metallic bone plates
Secure payment via Stripe
Payments accepted
YY 1040.2-2008
$75.00