YY 0837-2011Dental handpieces—Dental air-motors (English PDF)
牙科手机 牙科气动马达
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for YY 0837-2011 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
December 31, 2011
Implementation date
June 1, 2013
Scope
YY 0837-2011 is the English-translated version of 牙科手机 牙科气动马达.
YY 0837-2011 is the Chinese pharmaceutical industry standard for the dental air motor, the compressed air motor controlled by the dental unit to which a straight or contra-angle handpiece is connected.
It specifies the performance requirements and the test methods for it and for the manufacturer's instructions, the signs and the packaging, covering the speed and the torque delivered at the stated air pressure, the air and water supply and the exhaust, the noise, the connection to the handpiece and the sterilization of the parts.
It refers to GB 9706.1-2007. Issued on 31 December 2011, it has applied since 1 June 2013.
Found what you need?
Document preview — YY 0837-2011
National Standard of the People's Republic of China
- ICS
- 11.060.20
- Classification
- C 33
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions GB/T 9937.3-2008 and GB 9706.1-2007
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This revised standard adopts ISO 13294:1997 "Dental Handpiece Air Motor" (in English).
This standard and ISO 13294:1997 The main differences are as follows.
--- Delete references to IEC 651 normative documents and text referenced. 1979 "Sound Level Meter" and ISO 554. 1976 "standard atmosphere Conditioning and/or testing - technical requirements "of the two criteria;
--- With GB/T 6682-2008 "analytical laboratory use specifications and test methods" (ISO 3696. 1987, MOD) instead of ISO 3696. 1987 "Laboratory analysis of water specifications and test methods";
--- With YY/T 0149-2006 "stainless steel medical equipment corrosion test methods" (ISO 13402:1995, MOD) on behalf of the For ISO 13402:1995 "surgical and dental instruments handheld anti autoclaving, corrosion and thermal radiation determination";
--- With YY 1045.2-2010 instead of "handpieces - Part 2.. straight and curved handset phone" (1995, MOD ISO 7785-2)
ISO 7785-2:1995 "Handpiece Part 2. Straight and curved handset phone";
--- 4.3 will be "2.2.2" to "5.5";
--- 5.2.1 will be "at a water pressure of 250kPa (2.5bar) when" read "the water pressure is 200kPa (2.0bar) when";
--- 5.2.2 will be "in the pressure of 250kPa (2.5bar) when" replaced by "pressure 200kPa (2.0bar) is";
--- Remove the ISO 13294:1997 Annex A (informative). ISO 3964 This informative appendix lists. 1982 standard Referenced in 5.2.4, it should be included in this standard Chapter 2, "Normative references" on.
For ease of use, this standard also made the following editorial changes.
--- "This International Standard" be replaced by "this standard";
--- Delete ISO 13294:1997 introduction;
--- For other international standards referenced in this standard, if it has converted to our standards, the replacement of the International Standard for the standard references Corresponding national or industry standard number, and indicate the degree of consistency in Chapter 2 of this standard.
1 Scope
This standard specifies the control of dental treatment, dental straight and curved phone handset connected to a patient of dental air motor Test methods and performance requirements. This standard also regulates the manufacturer's instructions, signs and packaging.
This standard refers to GB 9706.1-2007 (basic safety standards for medical electrical equipment). Where there is a reference to the office were marked
GB 9706.1-2007 standard in terms of numbers.
Specified in this standard take precedence over the terms of GB 9706.1-2007 standard.
Only the terms of this standard is set out in the applicable.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6682-2008 analytical laboratory use specifications and test methods (ISO 3696. 1987, MOD)
GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT)
GB/T 9937.3-2008 Oral Vocabulary - Part 3.
YY/T 0149-2006 stainless steel medical equipment corrosion test methods (ISO 13402:1995, MOD)
YY/T 0514-2009 handpiece hose connector (ISO 9168:1991, IDT)
YY/T 0628-2008 dental equipment Graphical symbols (ISO 9687:1993, IDT)
YY 1012-2004 handpiece coupling dimensions (ISO 3964. 1982, IDT)
YY/T 1043-2004 dental unit (ISO 7494:1996, IDT)
YY 1045.2-2010 Dental handpieces - Part 2. Direct phone and handpieces (ISO 7785-2:1995, MOD)
ISO 4211. 1979 assessment of surface impedance appliance cryogenic liquid
3 Terms and Definitions
GB/T 9937.3-2008 and GB 9706.1-2007 terms and definitions defined in Chapter 2 apply to this document. Category 4
4.1 No-load speed range
Dental air motors are classified according to its no-load speed range (Table 1), or with air motor can be unworthy of the dental 5.2.7 Phone.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6682-2008Water for analytical laboratory use - Specification and test methods
- GB 9706.1-2007Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- YY/T 0149-2006Medical instruments of stainless steel - Test methods of corrosion resistance
- YY/T 0514-2009Dentistry—Hose connectors for air driven dental handpieces
- YY/T 0628-2008Dentistry—Graphical symbols for dental equipment
- YY 1012-2004Dental handpieces - Coupling dimensions
GB/T 9937.3-2008 · ISO 4211
Similar standards
How to Download YY 0837-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
YY 1012-2004 — Dental handpieces - Coupling dimensions
YY 1045.2-2010 — Dental handpieces - Part 2: Straight and geared angle handpieces