YY 0731-2009Large steam sterilizers - Manually controlled type (English PDF)

大型蒸汽灭菌器 手动控制型

Open the YY 0731-2009 preview as PDF

Preview — first pages of YY 0731-2009 (full document: 19 pages)

This is a limited preview

Buy now to download the full PDF (19 pages)

Issued by

NMPA

Level / Type

Industry · Mandatory

Issue date

June 16, 2009

Implementation date

December 1, 2010

Scope

YY 0731-2009 is the English-translated version of 大型蒸汽灭菌器 手动控制型.

YY 0731 is the mandatory Chinese standard for large manually controlled steam sterilizers, the autoclaves whose cycle is driven by an operator rather than by an automatic controller. They remain in service across county and township hospitals in China, where they sterilise instruments and dressings for whole departments. Manual control is what shapes the standard: with no controller enforcing the cycle, the requirements have to cover the instrumentation the operator reads, the chamber and its pressure vessel safety, the steam quality, the air removal that determines whether steam actually reaches the load, and the recording that shows a cycle was completed. It replaces YY 91008-1999 and YY 91009-1999. Compliance is compulsory in China.

Document preview — YY 0731-2009

National Standard of the People's Republic of China

ICS
11.080.10
Classification
C47
Replacing
YY 91008-1999; YY 91009-1999

Issued by: National Medical Products Administration

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Types and basic parameters
  • 5 Requirement
  • 6 Test methods
  • 7 Inspection rules
  • 12 References

Foreword

5.1.2 This standard is recommended, the rest are mandatory. This standard also replace the YY 91008-1999 "pressure steam sterilizer horizontal circular

--- technical conditions", YY 91009-1999 "pressure Power steam sterilizer technical conditions

--- horizontal rectangle "and other two pharmaceutical industry standards. Since the implementation of this standard, the above two criteria Abolished. Appendix B of this standard is a normative appendix, Appendix A is an information appendix. This standard was proposed by the State Food and Drug Administration. This standard by the National Standardization Technical Committee disinfection technology and equipment (SAC/TC200) centralized. This standard was drafted. State Food and Drug Administration Guangzhou Medical Device Quality Supervision and Inspection Center, Lianyungang SENOH medical equipment Ltd., Shanghai Medical Nuclear Instrument Co., Ltd. China line. The main drafters of this standard. Li Jing, Huang Xiulian, Hu Changming, Liuzhen Jian, Zheng Hongqin. This standard by the National Standardization Technical Committee disinfection technology and equipment responsible for the interpretation. This standard replaces the standards previously issued as follows:

--- YY 91008-1999, YY 91009-1999.

--- GB 4027.3-1983, GB 4027.4-1983. Large steam sterilizers manual control type

1 Scope

YY 0731 is the mandatory Chinese standard for large manually controlled steam sterilizers, the autoclaves whose cycle is driven by an operator rather than by an automatic controller. They remain in service across county and township hospitals in China, where they sterilise instruments and dressings for whole departments. Manual control is what shapes the standard: with no controller enforcing the cycle, the requirements have to cover the instrumentation the operator reads, the chamber and its pressure vessel safety, the steam quality, the air removal that determines whether steam actually reaches the load, and the recording that shows a cycle was completed. It replaces YY 91008-1999 and YY 91009-1999. Compliance is compulsory in China.

This standard specifies the terms and definitions manually controlled large steam sterilizer, type and basic parameters, requirements, test methods, inspection regulations Then, marking and instruction manual and packaging, transportation and storage. This standard applies to the rated working pressure of 0.25MPa or less, under the exhaust volume greater than 60L, manual control type steam off Bacteria filter (hereinafter referred to as sterilization). This standard does not apply to automatic control type large steam sterilizers, does not apply to vacuum type sterilizer.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB 150 steel pressure vessels

GB/T 191 Packaging - Pictorial signs ( GB/T 191-2008, ISO 780.1997, MOD)

GB/T 1226 General Pressure Gauge

GB 4793.1 measurement, control and laboratory safety requirements for electrical equipment Part 1. General requirements ( GB 4793.1- 2007, IEC 61010-1.2001, IDT)

GB 4793.4 measurement, control and laboratory use electrical safety laboratory equipment used in the treatment of medical materials to be autoclaved Particular Seek ( GB 4793.4-2001, idt IEC 61010-2-041.1995)

GB/T 7307 55 ° non-sealing pipe thread ( GB/T 7307-2001, eqv ISO 228-1.1994)

GB 9969.1 Instructions General Industrial Products

GB/T 12244 valve general requirements

GB/T 14710 Medical electrical equipment environmental requirements and test methods

GB/T 16839.2-1997 thermocouple Part 2. Tolerances (idt IEC 60584-2. 1982)

GB 18281.3 Sterilization of health care products - Biological indicators - Part 3. Biological indicators for moist heat sterilization ( GB 18281.3- 2000, idt ISO 11138-3.1995)

GB/T 19971 Sterilization of health care products Terminology (

GB/T 19971-2005, ISO /T S11139.2001, IDT)

3 Terms and Definitions

GB/T 19971 and identified the following terms and definitions apply to this standard.

3.1 Reaches sterilization temperature measurement from the reference point, to all parts of the load has reached the sterilizing temperature desired time.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

Normative references

GB 150 · ISO 780.1997 · GB 4793.1 · IEC 61010 · GB 4793.4-2001 · GB/T 7307-2001 · ISO 228 · GB 9969.1 · GB/T 16839.2-1997 · IEC 60584 · GB 18281.3 · ISO 11138 · GB/T 19971-2005 · JB/T 8622-1997 · IEC 751 · YY 0154 · YY/T 0158 · YY/T 0159

Editions of YY 0731

EditionTitleRevisionStatus
YY 0731-2009Large steam sterilizers - Manually controlled typecurrent editionCurrent
YY 91008-1999; YY 91009-1999Large steam sterilizers - Manually controlled typeprevious editionIn force until 2010-12-01

This page sells the current edition, YY 0731-2009. Earlier editions are listed for reference only.

How to Buy YY 0731-2009

  1. 1Add to cart. Click the "Buy YY 0731-2009" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 0731-2009

$290.00

$245.00for partners