YY 0676-2008Ophthalmic instruments - Perimeters (English PDF)
眼科仪器 视野计
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for YY 0676-2008 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
October 17, 2008
Implementation date
June 1, 2010
Scope
YY 0676-2008 is the English-translated version of 眼科仪器 视野计.
YY 0676-2008 is the Chinese pharmaceutical industry standard for the perimeter, the ophthalmic instrument that measures the differential light sensitivity of the visual field by asking the subject whether a stimulus on a background is seen.
It specifies the requirements and the test methods for such instruments, covering the background and stimulus luminance and their accuracy, the size and duration of the stimulus, the fixation control and the accuracy of the positions tested, and the recording of the result.
It does not apply to clinical psychological test methods nor to other methods of testing vision. Issued on 17 October 2008, it has applied since 1 June 2010.
Found what you need?
Document preview — YY 0676-2008
National Standard of the People's Republic of China
- ICS
- 11.040.70
- Classification
- C 40
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions Requirement
- 6 7 accompanying documents
- 7 mark
- Appendix A (Informative Appendix) Goldmann test prescribed stimulation points
- Annex B (informative) visual field coordinate system
Foreword
This revised standard adopts the International Standard ISO 12866:1999 "ophthalmic instruments perimeter." This standard and ISO 12866:1999 The main differences are as follows.
a) updating national mandatory safety standard requirements GB 9706.1 as "electrical safety requirements" indicators;
b) to ISO 10940. ISO 15004 1998 standard referenced in 1997 standard content, in addition to optical radiation security content of this standard In addition, combined with other requirements of the relevant standards applicability of provisions made directly described in this standard.
This standard is based on ISO 10940:1998 redrafting changes, modifications and technical differences made have been incorporated into the text in which they are involved Logo | Terms margin of a single vertical line (). The Standard Appendix A, Appendix B is an informative annex.
1 Scope
This standard specifies the requirements and test methods of perimetry. Perimeter is designed to lower perceived by a subjective test to determine the background thorn The presence of trigger points to evaluate vision light sensitivity difference.
This standard does not apply to clinical psychology test methods and methods for vision.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT)
GB/T 14710-1993 Medical electrical equipment environmental requirements and test methods
GB/T 16886.1-2001 Biological evaluation of medical devices - Part 1. Evaluation and testing (idt ISO 10993-1:1997)
GB/T 16886.5-2003 Biological evaluation of medical devices - Part 5. In vitro cytotoxicity tests (ISO 10993-5:1999, IDT)
GB/T 16886.10-2005 Biological evaluation of medical devices - Part 10.
ISO 15004:1997 basic equipment requirements and test methods Ophthalmology
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1 Visual field
Eyes set moment in time to perceive stimuli visible in all directions and the response to these stimuli perception.
3.1.4 All horizons beyond solid point of view 30 ° range
NOTE: To distinguish between central and peripheral visual field full field.
3.2 Perimeter
By examining the performance of the stimulus on a certain background to evaluate the visual field light sensitivity difference instruments.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 9706.1-2007Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- GB/T 14710-1993The environmental requirement and test methods for medical electrical equipment
- GB/T 16886.1-2001Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
- GB/T 16886.5-2003Biological evaluation of medical devices -- Part 5: Tests for in vitro cytotoxicity
- GB/T 16886.10-2005Biological evaluation of medical devices - Part 10: Tests for skin sensitization
ISO 15004:1997
Similar standards
How to Download YY 0676-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.1-2007 — Medical electrical equipment - Part 1: General requirements for safety
GB/T 14710-1993 — The environmental requirements and test methods for medical electrical equipment
GB/T 16886.1-2001 — Biological evaluation of medical devices - Part 1: Evaluation and testing
YY 0676-2008
$195.00