Valid

YY 0718-2009Ophthalmic instruments - Retinoscopes (English PDF)

眼科仪器 检影镜

Open the YY 0718-2009 preview as PDF

Preview — first pages of YY 0718-2009 (full document: 15 pages)

This is a limited preview

Buy now to download the full PDF (15 pages)

Issued by

NMPA

Level / Type

Industry · Mandatory

Issue date

June 16, 2009

Implementation date

December 1, 2010

Scope

YY 0718-2009 is the English-translated version of 眼科仪器 检影镜.

YY 0718 is the mandatory Chinese standard for retinoscopes, the handheld instruments used to determine a refractive error objectively by observing the reflex from the retina. Retinoscopy is how a prescription is obtained in patients who cannot answer questions: infants, young children, people with intellectual disability or language barriers, and it remains a core skill in Chinese optometry and paediatric ophthalmology. This document sets the requirements such an instrument has to meet and the test methods that verify them, covering the illumination system and the streak or spot it projects, the optical quality of the viewing path, the mechanical construction and the light exposure limits that protect the eye under examination. Being a YY standard without the /T suffix, compliance is compulsory in China. It carries Amendment 1 of 2023.

Document preview — YY 0718-2009

National Standard of the People's Republic of China

ICS
11.040.70
Classification
C40

Issued by: National Medical Products Administration

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Requirements

Foreword

This standard is equivalent to international standard ISO 12865.2006 "retinoscope ophthalmic instruments." For ease of use, this standard made the following editorial changes.

a) "this International Standard" be replaced by "this standard";

b) with a decimal point, instead of as a decimal comma ",". ",";

c) Remove the preface to international standards. This standard by the national medical and optical instruments Standardization Technical Committee and centralized. This standard was drafted. State Food and Drug Administration Hangzhou Medical Device Quality Supervision and Inspection Center. The main drafters of this standard. Wang Jingtao, JIA Xiao Hang Feng Qin. YY 0718-2009/ISO 12865.2006 Retinoscope ophthalmic instruments

1 Scope

YY 0718 is the mandatory Chinese standard for retinoscopes, the handheld instruments used to determine a refractive error objectively by observing the reflex from the retina. Retinoscopy is how a prescription is obtained in patients who cannot answer questions: infants, young children, people with intellectual disability or language barriers, and it remains a core skill in Chinese optometry and paediatric ophthalmology. This document sets the requirements such an instrument has to meet and the test methods that verify them, covering the illumination system and the streak or spot it projects, the optical quality of the viewing path, the mechanical construction and the light exposure limits that protect the eye under examination. Being a YY standard without the /T suffix, compliance is compulsory in China. It carries Amendment 1 of 2023.

The ISO 15004-1 standard and common provisions for objective measurement of the eye refractive errors ribbon optical retinoscope and point-like light retinoscopy mirror Minimum requirements and test methods. The ISO 15004-1 standard and if there is, the present standard in preference to ISO 15004-1.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety ( IEC 60601-1. 1988, IDT)

ISO 15004-1 ophthalmic instruments General requirements and test methods

3 Terms and Definitions

The following terms and definitions apply to this standard.

3.1 Objective assessment of the refractive error eye and retinal reflection cross over the pupil when the displacement of ophthalmic instruments by specular reflection beam. NOTE. retinoscope typically include analysis by the center through light microscopy or optical mirror projection system, observation system and power supply.

3.2 Can produce a focal length and orientation of the adjustable rectangular cross-section beam retinoscope.

3.3 Capable of generating a bundle of approximately circular cross-section beam retinoscope. NOTE. Focus image can be adjusted.

4 Requirements

4.1 General requirements Retinoscope should meet the general requirements specified in ISO 15004-1. Retinoscope shall comply with the requirements of

4.2 to 4.3. These requirements should be verified in accordance with the provisions of Chapter 5.

4.2 Optical and mechanical requirements Retinoscope shall comply with the requirements of Table 1. YY 0718-2009/ISO 12865.2006

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

How to Buy YY 0718-2009

  1. 1Add to cart. Click the "Buy YY 0718-2009" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 0718-2009

$70.00

$60.00for partners