YY 0585.3-2018Fluid lines for use with pressure infusion equipment and accessories for single use - Part 3: Filters (English PDF)
压力输液设备用一次性使用液路及附件 第3部分:过滤器
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for YY 0585.3-2018 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
November 7, 2018
Implementation date
May 1, 2020
Scope
YY 0585.3-2018 is the English-translated version of 压力输液设备用一次性使用液路及附件 第3部分:过滤器.
YY 0585.3-2018 is the Chinese pharmaceutical industry standard for the filters used with pressure infusion equipment.
It is the third part of the YY 0585 series and sets the requirements for their design, their materials, their physical, chemical and biological properties and their packaging, labelling and disposal, for fluid lines working at a pressure of up to 200 kPa.
It does not cover the effectiveness of a filter in removing particles or bacteria, which is left to the manufacturer's own validation. Issued on 7 November 2018, it applies from 1 May 2020.
Found what you need?
Document preview — YY 0585.3-2018
National Standard of the People's Republic of China
- Replacing
- YY 0585.3-2005
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 Design5
- 4 Materials6
- 5 Physical requirements6
- 6 Chemical requirements6
- 7 Biological requirements6
- 8 Packaging7
- 9 Label7
- 10 Disposal8
- Appendix A (Normative) Physical tests9
- Appendix B (Normative) Chemical tests10
- Appendix C (Normative) Biological tests11
- Appendix D (Informative) Technical differences from ISO 8536-11:2015 and the reasons therefor12
- Bibliography13
1 Scope
This Part of YY 0585 specifies the design, materials, physical, chemical and biological, packaging, labeling, and disposal requirements for filters for use with pressure infusion equipment, but does not include the effectiveness of filters in removing particles or bacteria.
This Part applies to fluid lines for infusion equipment with pressures not exceeding 200 kPa and to sterile infusion filters for single use with infusion sets as specified in YY 0286.4.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 1962.21) Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings (GB/T 1962.2-2015, ISO 594-2:1998, IDT)
GB 8368, Infusion sets for single use - Gravity feed (GB 8368-2018, ISO 8536-4:2010, MOD)
YY/T 0466.1 Medical devices - Symbols to be used with information to be supplied by the manufacturer - Part 1: General requirements (YY/T 0466.1-2016, ISO 15223-1:2012, IDT) Pharmacopoeia of the People's Republic of China
3 Design
The infusion filter housing shall be provided with a venting system to prevent air bubbles from accumulating and clogging the filter.
1) GB/T 1962 will be replaced by Part 7 of the YY/T 0916 series of standards (ISO 80369-7:2015, IDT).
4 Materials
The materials used to manufacture infusion filters shall meet the requirements specified in Chapters 5, 6 and 7.
5 Physical requirements
5.1 Transparency
The filter housing shall be transparent and, when tested according to A.1 of Appendix A, shall be able to distinguish the interface between water and air.
5.2 Particulate contamination
Infusion filters shall be manufactured under conditions of minimal particulate contamination. The inner surface shall be smooth and clean. When tested according to A.2, the contamination index shall not exceed the specified value.
5.3 Connection strength
When tested according to A.3, the infusion filter shall be able to withstand a static axial tensile force of not less than 15 N for 15 s.
5.4 Leakage
The filter housing shall be impermeable to microorganisms and liquids. The filter membrane and its connection to the housing shall not be broken. When tested according to A.4, there shall be no leakage of air or water.
5.5 Connectors with internal and/or external tapered joints
The connector shall have an internal tapered joint and/or an external tapered joint conforming to GB/T 1962.2.
5.6 Protective caps
GB 8368 applies.
6 Chemical requirements
GB 8368 applies; the test methods are given in Appendix B.
7 Biological requirements
GB 8368 applies; the test methods are given in Appendix C.
8 Packaging
GB 8368 applies
9 Label
9.1 General provisions
Labels shall comply with the provisions of 9.2 and 9.3. Graphic symbols, if used, shall comply with YY/T 0466.1.
Note. The symbol 2725 of ISO 7000 can be used to indicate the presence of a substance of concern, by replacing "×××" with the abbreviation of the substance, and crossing out the symbol if the substance of concern is not present.
9.2 Unit container
The unit container shall be marked with at least the following information.
a) Manufacturer's name and address;
b) Description of the content, such as infusion filter for single use;
c) Infusion filter free of pyrogens, or infusion filter free of bacterial endotoxins;
d) Graphic symbol given in YY/T 0466.1, indicating that the infusion filter is sterile;
e) Lot number, beginning with the word "LOT" or using the graphic symbol from YY/T 0466.1;
f) Corresponding text or graphic symbol given in YY/T 0466.1 indicating the expiration date (year and month);
g) Infusion filter for single use only, or equivalent in words, or in graphic symbols conforming to YY/T 0466.1;
h) Instructions for use, including warnings such as checking if the protective cover has come off;
i) The letter "P" representing pressure, which shall be larger than the surrounding text.
If the area of a unit container is too small to provide all the information and/or symbols, the information can be simplified to e) and f). In this case, the information required in this clause shall be provided on the label of the next larger shelf or multi-unit container.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of YY 0585.3
| Edition | Title | Revision | Status |
|---|---|---|---|
| YY 0585.3-2018 | Fluid lines for use with pressure infusion equipment and accessories for single use - Part 3: Filters | current edition | Current |
| YY 0585.3-2005 | Fluid lines for use with pressure infusion equipment and accessories for single use - Part 3: Filters | previous edition | Superseded |
This page sells the current edition, YY 0585.3-2018. Earlier editions are listed for reference only.
How to Download YY 0585.3-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 8368-2018 — Infusion sets for single use -- Gravity feed
YY/T 0466.1-2009 — Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
YY/T 0466.1-2016 — Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
Secure payment via Stripe
Payments accepted
YY 0585.3-2018
$165.00