YY 0465-2009Single-use hollow fiber plasma separators (English PDF)
一次性使用空心纤维血浆分离器
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for YY 0465-2009 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
June 16, 2009
Implementation date
December 1, 2010
Scope
YY 0465-2009 is the English-translated version of 一次性使用空心纤维血浆分离器.
YY 0465-2009 is the Chinese standard "Single-use hollow fiber plasma separators". Its scope clause reads: This standard specifies the terms and definitions, requirements, test method, inspection rules, marking, packaging, transportation and storage of disposable membrane plasmaseparator.
This standard is applicable to disposable membrane plasmaseparator, hereinafter referred to as plasmaseparator.
The plasmaseparator is used in conjunction with plasmaseparation system to treat critically ill patients suffering from various immunological diseases, metabolic disorder and some toxic action, etc. Its clauses include terms and definitions.
Found what you need?
Document preview — YY 0465-2009
National Standard of the People's Republic of China
- Replacing
- YY 0465-2003
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword i
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 Classification and Designation
- 5 Requirements
- 6 Test Method
- 7 Inspection Rules
- 8 Marking
- 9 Packaging, Transportation and Storage
- Annex A (Normative) Method for Determination of Particle Content in Plasmaseparator
- Annex B (Normative) Determination of Permeability of Plasmaseparator
- Annex C (Normative) Method for Determination of Protein Sieving Coefficient of Plasmaseparator
1 Scope
This standard specifies the terms and definitions, requirements, test method, inspection rules, marking, packaging, transportation and storage of disposable membrane plasmaseparator.
This standard is applicable to disposable membrane plasmaseparator, hereinafter referred to as plasmaseparator. The plasmaseparator is used in conjunction with plasmaseparation system to treat critically ill patients suffering from various immunological diseases, metabolic disorder and some toxic action, etc.
2 Normative References
The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections) to, or revisions, of any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest editions apply.
GB/T 191 Packaging—Pictorial Marking for Handling of Goods
GB/T 13074 Terms of Blood Purification
GB/T 14233.1-2008 Test Methods for Infusion, Transfusion, Injection Equipments for Medical Use—Part 1: Chemical Analysis Methods
GB/T 16886.1 Biological Evaluation of Medical Devices—Part 1: Evaluation and Testing (GB/T 16886.1-2001, idt ISO 10993-1:1997)
GB/T 16886.4 Biological Evaluation of Medical Devices—Part 4: Selection of Tests for Interactions with Blood (GB/T 16886.4-2003, ISO 10993-4:2002, IDT)
GB/T 16886.5 Biological Evaluation of Medical Devices—Part 5: Tests for In Vitro Cytotoxicity (GB/T 16886.5-2003, ISO 10993-5:1999, IDT)
GB/T 16886.10 Biological Evaluation of Medical Devices—Part 10: Tests for Irritation and Delayed-type Hypersensitivity (GB/T 16886.10-2005, ISO 10993-10:2002, IDT)
GB/T 16886.11 Biological Evaluation of Medical Devices—Part 11: Tests for Systemic Toxicity (GB/T 16886.11-1997, idt ISO 10993-11:1993)
Pharmacopoeia of the People's Republic of China (Edition 2005)
3 Terms and Definitions
For the purposes of this standard, the terms and definitions given in GB/T 13074 and the followings apply.
3.1 plasmaseparation
process of separating plasma and formed element in blood
3.2 plasmaseparation system
device consisting of hemodynamic system, monitoring system, capacity balancing system and plasmaseparator, etc.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of YY 0465
| Edition | Title | Revision | Status |
|---|---|---|---|
| YY 0465-2009 | Single-use hollow fiber plasma separators | current edition | Current |
| YY 0465-2003 | Single-use hollow fiber plasma separators | previous edition | Superseded |
This page sells the current edition, YY 0465-2009. Earlier editions are listed for reference only.
How to Download YY 0465-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY 0465-2009
$235.00