Valid

YS/T 820.26-2012Methods for chemical analysis of laterite nickel ores. Part 26: Determination of loss on ignition. Gravimetric method (English PDF)

红土镍矿化学分析方法 第26部分:灼烧减量的测定 重量法

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for YS/T 820.26-2012 in 30 minutes.

Issued by

Ministry of Industry and Information Technology of PRC

Level / Type

National · Recommended

Issue date

November 7, 2012

Implementation date

March 1, 2013

Scope

YS/T 820.26-2012 is the English-translated version of 红土镍矿化学分析方法 第26部分:灼烧减量的测定 重量法.

YS/T 820.26-2012 — This part of YS/T 820 specifies the gravimetric method for the determination of loss on ignition (LOI) in laterite nickel ore. This part applies to the determination of loss on ignition in laterite nickel ore. The measurement range is 6.00%~14.00%.

Found what you need?

Document preview — YS/T 820.26-2012

National Standard of the People's Republic of China

ICS
73.060

Issued by: Ministry of Industry and Information Technology of PRC

Contents

  • Foreword3
  • 1 Scope6
  • 2 Method summary6
  • 3 Instruments6
  • 4 Samples6
  • 5 Analysis steps6
  • 6 Calculation of analysis results7
  • 7 Precision7
  • 8 Test report8

Foreword

This part is drafted in accordance with the provisions of GB/T 1.1-2009.

YS/T 820-2012 "Methods for chemical analysis of lateritic nickel ore" is divided into 26 parts.

- Part 1: Determination of nickel content. Flame atomic absorption spectrometry;

- Part 2: Determination of nickel content. Dimethylglyoxime spectrophotometry;

- Part 3: Determination of total iron content. Potassium dichromate titration;

- Part 4: Determination of phosphorus content. Phosphorus molybdenum blue spectrophotometry;

- Part 5: Determination of cobalt content. Flame atomic absorption spectrometry;

- Part 6: Determination of copper content. Flame atomic absorption spectrometry;

- Part 7: Determination of calcium and magnesium content. Flame atomic absorption spectrometry;

- Part 8: Determination of silica content. Potassium silico-fluoride titrimetric method;

- Part 9: Determination of scandium and cadmium contents. Inductively coupled plasma mass spectrometry;

- Part 10: Determination of calcium, cobalt, copper, magnesium, manganese, nickel, phosphate and zinc content. Inductively coupled plasma atomic emission spectrometry;

- Part 11: Determination of fluorine and chlorine contents. Ion chromatography;

- Part 12: Determination of manganese content. Flame atomic absorption spectrometry;

- Part 13: Determination of lead content. Flame atomic absorption spectrometry;

- Part 14: Determination of zinc content. Flame atomic absorption spectrometry;

- Part 15: Determination of cadmium content. Flame atomic absorption spectrometry;

- Part 16: Determination of carbon and sulfur content. High frequency combustion with infrared absorption spectrometry - Part 17: Determination of arsenic, antimony and bismuth contents. Hydride generation-atomic fluorescence spectrometry;

- Part 18: Determination of mercury content. Cold atomic absorption spectrometry;

- Part 19: Determination of aluminum, chromium, iron, magnesium, manganese, nickel and silicon contents. Energy-dispersive X-ray fluorescence spectrometry;

- Part 20: Determination of aluminum content. EDTA titration;

- Part 21: Determination of chromium content. The ammonium-ferrous sulfate titration method;

- Part 22: Determination of magnesium content. EDTA titration;

- Part 23: Determination of cobalt, iron, nickel, phosphorus, aluminium oxide, calcium oxide, chromium oxide, magnesium oxide, manganese oxide, silicon dioxide and titanium dioxide content. Wavelength dispersive X-ray fluorescence spectrometry;

- Part 24: Determination of hygroscopic moisture content. Gravimetric method;

- Part 25: Determination of combined water content. Gravimetric method;

- Part 26: Determination of loss on ignition. Gravimetric method.

This part is Part 26 of YS/T 820-2012.

This standard shall be under the jurisdiction of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243).

1 Scope

This part of YS/T 820 specifies the gravimetric method for the determination of loss on ignition (LOI) in laterite nickel ore.

This part applies to the determination of loss on ignition in laterite nickel ore.

The measurement range is 6.00%~14.00%.

2 Method summary

Ignite the pre-dried sample to a constant weight at 1000 °C; calculate the loss on ignition (LOI) according to the reduced mass of the sample.

3 Instruments

3.1 High-temperature furnace. the temperature can be controlled at 1000 °C±50 °C.

4 Samples

The particle size of the samples shall be less than 160 µm; bake them in an oven at 105 °C~110 °C for 2 h, and cool them to room temperature in a desiccator.

5 Analysis steps

5.1 Sample

Weigh 1.00 g sample; the weight shall be accurate to 0.0002 g.

5.2 Number of measurements

Independently perform two measurements; take the average value.

5.3 Determination steps

Place the sample in a porcelain crucible (3.2), and put the crucible in a high-temperature furnace (3.1);

6 Calculation of analysis results

The loss on ignition is calculated according to formula (1), the result is expressed in terms of the mass fraction omegaLOI of the loss on ignition, its value is expressed in %.

7 Precision

7.1 Repeatability

The two independent tests' determination results obtained under repeatability conditions shall be within the range of average values given below.

7.2 Reproducibility

Two independent tests' determination results are obtained under reproducible conditions.

8 Test report

This chapter specifies the content of the test report. At least the following content shall be given.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

How to Download YS/T 820.26-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 820.26-2012

$105.00