Valid

YS/T 820.1-2012Methods for chemical analysis of laterite nickel ores - Part 1: Determination of nickel content - Flame atomic absorption spectrometry (English PDF)

红土镍矿化学分析方法 第1部分:镍量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for YS/T 820.1-2012 in 30 minutes.

Issued by

Ministry of Industry and Information Technology of PRC

Level / Type

National · Recommended

Issue date

November 7, 2012

Implementation date

March 1, 2013

Scope

YS/T 820.1-2012 is the English-translated version of 红土镍矿化学分析方法 第1部分:镍量的测定 火焰原子吸收光谱法.

YS/T 820.1-2012 — This part of YS/T 820 specifies the determination method of nickel content in laterite nickel ores. This part applies to the determination of the nickel content in laterite nickel ores. The measuring range is 0.100%~3.00%.

Found what you need?

Document preview — YS/T 820.1-2012

National Standard of the People's Republic of China

ICS
73.060
Classification
D 04

Issued by: Ministry of Industry and Information Technology of PRC

Contents

  • Foreword...3
  • 1 Scope...6
  • 2 Normative references...6
  • 3 Method summary...6
  • 4 Reagents...6
  • 5 Instruments...7
  • 6 Samples...7
  • 7 Analysis steps...8
  • 8 Calculation of analysis results...9
  • 9 Precision...10
  • 10 Test report...10

Foreword

This part was drafted in accordance with the rules given in GB/T 1.1-2009.

YS/T 820-2012 Methods for chemical analysis of laterite nickel ores is divided into 26

parts:

-- Part 1: Determination of nickel content - Flame atomic absorption spectrometry;

-- Part 2: Determination of nickel content - Dimethylglyoxime spectrophotometry;

-- Part 3: Determination of total iron content - Potassium dichromate titration;

-- Part 4: Determination of phosphorus content - Phosphorus molybdenum blue

spectrophotometry;

-- Part 5: Determination of cobalt content - Flame atomic absorption spectrometry;

-- Part 6: Determination of copper content - Flame atomic absorption spectrometry;

-- Part 7: Determination of calcium and magnesium content - Flame atomic

absorption spectrometry;

-- Part 8: Determination of silica content - Potassium silicafluoride titrimetric

method;

-- Part 9: Determination of scandium and cadmium contents - Inductively coupled

plasma mass spectrometry;

-- Part 10: Determination of calcium, cobalt, copper, magnesium, manganese,

nickel, phosphate and zinc content - Inductively coupled plasma atomic

emission spectrometry;

-- Part 11: Determination of fluorine and chlorine contents - Ion chromatography;

-- Part 12: Determination of manganese content - Flame atomic absorption

spectrometry;

-- Part 13: Determination of lead content - Flame atomic absorption spectrometry;

-- Part 14: Determination of zinc content - Flame atomic absorption spectrometry;

-- Part 15: Determination of cadmium content - Flame atomic absorption

spectrometry;

-- Part 16: Determination of carbon and sulfur content - High frequency combustion

with infrared absorption spectrometry;

Methods for chemical analysis of laterite nickel ores - Part 1:

Determination of nickel content - Flame atomic absorption

spectrometry

1 Scope

This part of YS/T 820 specifies the determination method of nickel content in laterite

nickel ores.

This part applies to the determination of the nickel content in laterite nickel ores. The

measuring range is 0.100%~3.00%.

2 Normative references

The following documents are essential for the application of this document. For the

dated referenced documents, only the versions with the indicated dates are applicable

to this document; for the undated referenced documents, only the latest version

(including all the amendments) is applicable to this document.

YS/T 820.24-2012 Methods for chemical analysis of laterite nickel ores - Part 24:

Determination hygroscopic moisture content - Gravimetric method

3 Method summary

The sample is decomposed with hydrochloric acid, nitric acid, hydrofluoric acid, and

perchloric acid. Salts are dissolved with hydrochloric acid; in a dilute hydrochloric acid

medium, at the wavelength of 232.0 nm of an atomic absorption spectrometer, with the

use of an air-acetylene flame, the absorbance of nickel is measured, and then the nickel

content is calculated.

4 Reagents

Unless otherwise stated, only reagents confirmed to be analytical grade and distilled or

deionized water or water of equivalent purity are used in the analysis.

4.1 Hydrochloric acid (rho1.19 g/mL).

4.2 Nitric acid (rho1.42 g/mL).

4.3 Hydrofluoric acid (rho1.15 g/mL).

4.4 Perchloric acid (rho1.67 g/mL).

4.5 Nitric acid (1+1).

4.6 Nickel standard storage solution: Weigh 1.0000 g of metallic nickel (wNi >=99.95%),

place it in a 400 mL beaker, and add 50 mL of nitric acid (4.5) to dissolve it completely;

heat and boil to drive off nitrogen oxides, then remove the beaker to stop heating, and

cool to room temperature; transfer the solution to a 1000 mL volumetric flask, dilute it

to the mark with water, and mix well. 1 mL of this solution contains 1 mg of nickel.

4.7 Nickel standard solution: Pipette 10.00 mL of nickel standard stock solution (4.6)

into a 100 mL volumetric flask, add 5 mL of hydrochloric acid (4.1), dilute to the mark

with water, and mix well. 1 mL of this solution contains 100 µg nickel.

5 Instruments

The atomic absorption spectrometer shall be equipped with a nickel hollow cathode

lamp.

Under the working conditions of the instrument, any atomic absorption spectrometer

that can achieve the following indicators can be used:

-- Characteristic concentration: In the solution that is basically consistent with the

measuring test solution, the characteristic concentration of nickel shall not be

greater than 0.08 µg/mL;

-- Precision: The absorbance is measured 10 times with the standard solution of the

maximum concentration, and the standard deviation shall not exceed 1% of the

average absorbance; the absorbance is measured 10 times with the standard

solution of the minimum concentration (not "zero" standard solution), and the

standard deviation shall not exceed 0.5% of the average absorbance of the

standard solution with the maximum concentration;

-- Working curve linearity: The working curve is divided into five equal parts

according to the concentration, and the ratio of the absorbance difference of the

highest section to the absorbance difference of the lowest section shall not be

less than 0.70.

6 Samples

6.1 Samples

7.4.3 Put the test solution (7.4.2) at the wavelength of 232.0 nm of the atomic absorption

spectrometer, use an air-acetylene flame, carry out zero setting with water, and measure

the absorbance of the test solution and the blank solution. Check the corresponding

nickel concentration from the working curve.

7.5 Drawing of the working curve

7.5.1 Pipette 0 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL, 5.00 mL of nickel standard

solution (4.7) into a set of 100 mL volumetric flasks, add 5 mL hydrochloric acid (4.1),

dilute to the mark with water, and mix well.

7.5.2 Use the air-acetylene flame, and set the atomic absorption spectrometer to zero

with water at the wavelength of 232.0 nm. Measure the absorbance of the series of

standard solutions, subtract the absorbance of the "zero" concentration solution in the

series of standard solutions, and draw the working curve with the concentration of

nickel as the abscissa and the absorbance as the ordinate.

8 Calculation of analysis results

The nickel content is expressed as the mass fraction wNi of nickel, and the value is

expressed in %, calculated according to formula (1):

where:

rho1 -- the concentration of nickel in the measuring solution obtained from the

working curve, in micrograms per milliliter (µg/mL);

rho2 -- the concentration of nickel in the blank solution obtained from the working

curve, in micrograms per milliliter (µg/mL);

V0 -- the total volume of the test solution, in milliliters (mL);

V1 -- the volume of the test solution taken, in milliliters (mL);

V2 -- the volume of the measuring solution, in milliliters (mL);

m -- the mass of the sample, in grams (g);

K -- conversion factor, calculated according to formula (2);

A -- the mass fraction of the hygroscopic moisture content measured according to

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

Normative references

YS/T 820.24-2012

How to Download YS/T 820.1-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 820.1-2012

$105.00