YS/T 820.16-2012Methods for chemical analysis of laterite nickel ores - Part 16: Determination of carbon and sulfur content - High frequency combustion with infrared absorption spectrometry (English PDF)
红土镍矿化学分析方法 第16部分:碳和硫量的测定 高频燃烧红外吸收光谱法
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for YS/T 820.16-2012 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of PRC
Level / Type
National · Recommended
Issue date
November 7, 2012
Implementation date
March 1, 2013
Scope
YS/T 820.16-2012 is the English-translated version of 红土镍矿化学分析方法 第16部分:碳和硫量的测定 高频燃烧红外吸收光谱法.
YS/T 820.16-2012 is the Chinese standard "Methods for chemical analysis of laterite nickel ores - Part 16: Determination of carbon and sulfur content - High frequency combustion with infrared absorption spectrometry".
Its scope clause reads: This part of YS/T 820 specifies the method for the determination of carbon and sulfur content in laterite nickel ore. This part applies to the determination of carbon and sulfur content in laterite nickel ore.
Measuring range: carbon 0.0060%~0.40%, sulfur 0.0020%~0.20%. Its clauses include method summary; reagents and materials; instruments; samples; analysis steps. It was issued by the Ministry of Industry and Information Technology of PRC on 2012-11-07 and took effect on 2013-03-01.
Found what you need?
Document preview — YS/T 820.16-2012
National Standard of the People's Republic of China
- ICS
- 73.060
- Classification
- D 04
Issued by: Ministry of Industry and Information Technology of PRC
Contents
- Foreword...3
- 1 Scope...6
- 2 Method summary...6
- 3 Reagents and materials...6
- 4 Instruments...7
- 5 Samples...7
- 6 Analysis steps...7
- 7 Precision...9
- 8 Test report...9
1 Scope
This part of YS/T 820 specifies the method for the determination of carbon and sulfur content in laterite nickel ore.
This part applies to the determination of carbon and sulfur content in laterite nickel ore. Measuring range: carbon 0.0060%~0.40%, sulfur 0.0020%~0.20%.
2 Method summary
The sample is heated and burned in the oxygen flow of the high-frequency induction furnace; the generated carbon dioxide and sulfur dioxide are carried by the oxygen to the infrared analyzer for measurement. In the measuring chamber, carbon dioxide and sulfur dioxide absorb infrared energy of a certain wavelength; the absorption energy is proportional to its concentration.
According to the change of absorption energy tested by the detector, the carbon and sulfur content can be measured.
3 Reagents and materials
Unless otherwise stated, only reagents confirmed to be analytical reagents were used in the analysis.
3.1 Pure iron fluxing agent: particle size< 1.25 mm, C< 0.0005%, S< 0.0005%.
3.2 Tungsten-tin mixed fluxing agent: the ratio is 9:1, C< 0.0010%, S< 0.0005%.
3.3 Barium carbonate shall be fine powder with a content of more than 99.9%.
Dry at 105 °C for 3 h and cool in a desiccator.
3.4 Standard sample: certified reference material with carbon and sulfur content
similar to the sample to be tested.
Note: It is better to use ore (or iron ore) reference material with similar composition.
3.5 The ceramic crucibles shall be burned for 4 hours in a high-temperature heating furnace higher than 1000 °C, or burned with oxygen until the blank value is the lowest; then, cool them in a desiccator for later use.
4 Instruments
High-frequency induction infrared carbon and sulfur analyzer.
The instrument shall be able to reach the following indicators:
- Power of the high-frequency furnace: 1.0 kW~2.5 kW;
- Frequency: greater than 6.0 MHz;
- Sensitivity of the detector: higher than 0.0001%.
5 Samples
The particle size of the samples shall be less than 160 µm; bake them in an oven at 105 °C~110 °C for 2 h, and cool them to room temperature in a desiccator.
6 Analysis steps
6.1 Sample
Weigh 0.10 g sample; the weight shall be accurate to 0.0001 g.
6.2 Number of measurements
Independently perform two measurements; take the average value.
6.3 Instrument Preparation
Prepare the instrument for use according to the recommended conditions for the instrument. Adjust and stabilize the instrument by burning several samples similar to the one to be tested.
6.4 Blank value calibration
Weigh 1.0 g of pure iron fluxing agent (3.1) and 1.0 g~1.5 g of tungsten-tin mixed fluxing agent (3.2) in turn; place them in the burnt crucible (3.5) to measure the amounts of carbon and sulfur; then obtain the blank values of
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download YS/T 820.16-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 820.1-2012 — Methods for chemical analysis of laterite nickel ores - Part 1: Determination of nickel content - Flame atomic absorption spectrometry
YS/T 820.10-2012 — Methods for chemical analysis of laterite nickel ores - Part 10: Determination of calcium, cobalt, copper, magnesium, manganese, nickel, phosphate and zinc content - Inductively coupled plasma atomic emission spectrometry
YS/T 820.11-2012 — Methods for chemical analysis of laterite nickel ores. Part 11: Determination of fluorine and chlorine contents. Ion chromatography
Secure payment via Stripe
Payments accepted
YS/T 820.16-2012
$105.00