YS/T 630-2016Chemical analysis method of alumina - Determination of impurities in alumina - ICP-AES analytical method (English PDF)
氧化铝化学分析方法杂质元素含量的测定电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for YS/T 630-2016 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of PRC
Level / Type
National · Recommended
Issue date
July 11, 2016
Implementation date
January 1, 2017
Scope
YS/T 630-2016 is the English-translated version of 氧化铝化学分析方法杂质元素含量的测定电感耦合等离子体原子发射光谱法.
YS/T 630-2016 is the Chinese standard "Chemical analysis method of alumina - Determination of impurities in alumina - ICP-AES analytical method".
Its scope clause reads: This standard specifies the method for determining the content of impurity elements such as silicon dioxide, ferric oxide, sodium oxide, potassium oxide, copper oxide, magnesium oxide, calcium oxide, boron trioxide, chromium trioxide, vanadium pentoxide, zinc oxide, titanium dioxide, manganese oxide, gallium trioxide, lithium oxide, and beryllium oxide in alumina.
This standard applies to the determination of the content of impurity elements such as silicon dioxide, ferric oxide, sodium oxide, potassium oxide, copper oxide, magnesium oxide, calcium oxide, boron trioxide, chromium trioxide, vanadium pentoxide, zinc oxide, titanium dioxide, manganese oxide, gallium trioxide, lithium oxide, and beryllium oxide in alumina.
The measurement range is shown in Table 1. Table 1 -- Measurement range. Its clauses include method summary; reagents and materials; instruments; samples; analysis steps; calculation of measurement results.
It was issued by the Ministry of Industry and Information Technology of PRC on 2016-07-11 and took effect on 2017-01-01.
Found what you need?
Document preview — YS/T 630-2016
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 12
Issued by: Ministry of Industry and Information Technology of PRC
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Method summary...5
- 4 Reagents and materials...5
- 5 Instruments...6
- 6 Samples...6
- 7 Analysis steps...6
- 8 Calculation of measurement results...7
- 9 Precision...8
- 10 Quality control and assurance...10
1 Scope
This standard specifies the method for determining the content of impurity elements such as silicon dioxide, ferric oxide, sodium oxide, potassium oxide, copper oxide, magnesium oxide, calcium oxide, boron trioxide, chromium trioxide, vanadium pentoxide, zinc oxide, titanium dioxide, manganese oxide, gallium trioxide, lithium oxide, and beryllium oxide in alumina.
This standard applies to the determination of the content of impurity elements such as silicon dioxide, ferric oxide, sodium oxide, potassium oxide, copper oxide, magnesium oxide, calcium oxide, boron trioxide, chromium trioxide, vanadium pentoxide, zinc oxide, titanium dioxide, manganese oxide, gallium trioxide, lithium oxide, and beryllium oxide in alumina. The measurement range is shown in Table 1.
Table 1 -- Measurement range
2 Normative references
The following documents are essential for the application of this document. For any dated referenced document, only the dated version applies to this document. For any undated referenced document, the latest version (including all amendments) applies to this document.
GB/T 602 Chemical reagent - Preparations of standard solutions for impurity (ISO
6353-1.1982, NEQ)
Impurity element Measurement range (mass fraction)/%
Vanadium pentoxide
Impurity element Measurement range (mass fraction)/%
Silicon dioxide
Ferric oxide
Sodium oxide
Potassium oxide
Copper oxide
Magnesium oxide
Calcium oxide
Boron trioxide
Chromium trioxide
Zinc oxide
Titanium dioxide
Manganese oxide
Gallium trioxide
Lithium oxide
Beryllium oxide
3 Method summary
Under the action of a microwave digestion system, the test specimen is digested with sulfuric acid at high temperature and high pressure, and the test solution is introduced into argon plasma. Under the selected optimal operating conditions, the impurity element content is determined by an inductively coupled plasma spectrometer, and the matrix matching method is used to correct the influence of the matrix on the determination.
4 Reagents and materials
4.1 Argon (with a purity of >=99.99%).
4.2 Sulfuric acid (1+2). Guaranteed or UP grade.
4.3 Sulfuric acid (1+1). Guaranteed or UP grade.
4.4 High-purity aluminum (>=99.999%).
4.5 Deionized water or ultrapure water.
4.6 Aluminum matrix solution (20 mg/mL). Weigh 5.2873 g of high-purity aluminum
(4.4) into a 1000 mL beaker; add 400 mL of sulfuric acid (4.3), place the beaker on an electric stove, and slowly heat until completely dissolved. Cool, transfer the solution to a 500 mL volumetric flask, dilute to the mark with water, mix thoroughly, and store in a polyethylene bottle. 1 mL of this solution contains 20 mg of aluminum oxide.
4.7 Standard storage solution
4.7.1 Prepare standard solutions of silicon, iron, sodium, potassium, copper, magnesium, calcium, chromium, vanadium, zinc, titanium, manganese, gallium, lithium, beryllium, and boron according to GB/T 602, with the concentrations of silicon, potassium, vanadium, and titanium at 100 µg/mL and those of iron, sodium, copper, magnesium, calcium, chromium, zinc, manganese, gallium, lithium, beryllium, and boron at 1000
µg/mL.
4.8 Mixed standard solution. Pipette 10.00 mL each of the iron and calcium standard solutions (4.7), 50.00 mL of the sodium standard solution (4.7), 5.00 mL each of the copper, magnesium, chromium, zinc, manganese, gallium, lithium, beryllium, and boron standard solutions (4.7), and 50.00 mL each of the vanadium and titanium standard solutions (4.7) into a 250 mL volumetric flask, dilute to the mark with water, mix thoroughly, and transfer to a polyethylene bottle for storage. This solution contains
40 µg/mL each of iron and calcium, 200 µg/mL of sodium, and 20 µg/mL each of copper, magnesium, chromium, vanadium, zinc, titanium, manganese, gallium, lithium, beryllium and boron.
5 Instruments
5.1 Inductively Coupled Plasma-Atomic Emission Spectrometer (ICP-AES).
5.2 Dryer. New activated alumina is used as the desiccant.
5.3 Microwave digestion apparatus. with a rated temperature of 300 °C, and a digestion vessel volume of 100 mL.
5.4 Polytetrafluoroethylene sealed sample dissolver (autoclave).
5.5 Electronic balance. The sensitivity is 0.0001 g.
5.6 Oven. 300 °C±10 °C.
6 Samples
6.1 The sample shall pass through a sieve with an aperture of 0.125 mm.
6.2 The sample shall be dried in an oven (5.6) at 300 °C±10 °C for 2 hours and placed in a desiccator (5.2) to cool to room temperature.
7 Analysis steps
7.1 Test specimen
Weigh 0.2 g of the sample (Chapter 6) to the nearest 0.0001 g.
7.2 Number of measurements
Two measurements shall be performed independently, and the average value shall be taken.
7.3 Blank test
A blank test shall be performed along with the specimen test.
7.4 Preparation of analytical solution
7.4.1 Place the specimen (7.1) in a polytetrafluoroethylene digestion vessel, add 12.0
mL of sulfuric acid (4.2), and digest in a microwave digester (5.3) until the sample is completely dissolved. Remove the digestion vessel, cool to room temperature, transfer the solution to a 100 mL volumetric flask, dilute to the mark with water, and mix thoroughly.
7.4.2 Place the specimen (7.1) in a polytetrafluoroethylene reaction cup, add 12.0 mL
of sulfuric acid (4.2), and cover tightly. Place the reaction cup in a sample dissolver and cover tightly. Heat the dissolver to 240 °C±2 °C in an oven, maintain for 6 hours, remove the dissolver, and allow it to cool naturally to room temperature. Remove the reaction cup, transfer the solution to a 100 mL volumetric flask, dilute to the mark with water, and mix thoroughly.
7.5 Preparation of standard series solutions
7.5.1 Pipette 0 mL, 1.00 mL, 3.00 mL, 5.00 mL, 8.00 mL, and 10.00 mL of the silicon standard solution (4.7) into a set of 100 mL volumetric flasks. Add 10.00 mL of the aluminum matrix solution (4.6) to each flask. Dilute to the mark with water, mix thoroughly, and store in polyethylene bottles.
7.5.2 Pipette 0 mL, 1.00 mL, 3.00 mL, 5.00 mL, 8.00 mL, and 10.00 mL of potassium standard solution (4.7) into a set of 100 mL volumetric flasks. Add 10.00 mL of aluminum matrix solution (4.6) to each flask. Dilute to the mark with water, mix well, and store in polyethylene bottles.
7.6 Determination
Under the selected instrument's optimal working conditions, measure the standard series solutions (7.5) and the analytical solution (7.4).
8 Calculation of measurement results
The contents of the standard series solutions are directly input into the corresponding computer software system. Based on the strength values of the standard series solutions and the analytical solution, the computer calculates, corrects, and outputs the concentration (µg/mL) of the element to be measured in the analytical solution. The mass fraction of each element to be measured is calculated according to formula (1).
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 630-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 602-2026 — Chemical reagent - Preparation of standard solutions for impurity determination
GB/T 6020-2008 — Butadiene for industrial use -- Determination of tert-butyl-catechol (TBC)
GB/T 6022-2008 — Butadiene for industrial use - Determination of oxygen in gaseous phase above liquid butadiene
Secure payment via Stripe
Payments accepted
YS/T 630-2016
$125.00