YS/T 1050.7-2015Methods for chemical analysis of lead antimony concentrates - Part 7: Determination of bismuth and copper contents - Flame atomic absorption spectrometric method (English PDF)

铅锑精矿化学分析方法 第7部分:铋量和铜量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 1050.7-2015 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

April 30, 2015

Implementation date

October 1, 2015

Scope

YS/T 1050.7-2015 is the English-translated version of 铅锑精矿化学分析方法 第7部分:铋量和铜量的测定 火焰原子吸收光谱法.

YS/T 1050.7-2015 — This section YS/T 1050 specifies the method for measuring the amount of bismuth in lead-antimony concentrate and copper content.

This section applies to the determination of the amount of bismuth in the lead-antimony concentrate and copper content of the measurement range (mass fraction) of 0.015% to 1.00% bismuth, copper from 0.15% to 1.00%.

Found what you need?

Document preview — YS/T 1050.7-2015

National Standard of the People's Republic of China

ICS
73.060
Classification
D 42

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instruments and equipment

Foreword

YS/T 1050-2015 "Methods for chemical analysis of lead-antimony concentrate" is divided into the following nine sections.

--- Part 1. Determination of lead content Na2EDTA titration;

--- Part 2. Determination of antimony content cerium sulfate titration;

--- Part 3. Determination of arsenic content potassium bromate titration;

--- Part 4. Determination of zinc contents Na2EDTA titration;

--- Part 5. Determination of sulfur content - Gravimetric method;

--- Part 6. Determination of iron content cerium sulfate titration;

--- Part 7. Determination of the amount of bismuth and copper - Flame atomic absorption spectrometry amount;

--- Part 8. gold and silver content determination fire assay;

--- Part 9. Determination of the amount of silver by flame atomic absorption spectrometry.

This is Part 7.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is responsible for drafting unit. Guangxi Metallurgical Product Quality Supervision and Inspection Station.

This section is drafted. Guilin University of Technology.

Participated in the drafting of this section. Beijing Mining Research Institute, Guangxi Zhuang Autonomous Region Analysis and Testing Center, Liuzhou one hundred Ren special advanced material Material Limited.

1 Scope

This section YS/T 1050 specifies the method for measuring the amount of bismuth in lead-antimony concentrate and copper content.

This section applies to the determination of the amount of bismuth in the lead-antimony concentrate and copper content of the measurement range (mass fraction) of 0.015% to 1.00% bismuth, copper from 0.15% to 1.00%.

2 Method summary

Sample with nitric acid, potassium chlorate and sulfuric acid decomposition in hydrochloric acid medium, with air - acetylene flame atomic absorption spectrometer wavelength 223.1nm and 324.8nm at bismuth and copper were measured absorbance to the standard curve method to calculate the amount of bismuth and copper content.

3 Reagents

Unless otherwise indicated, this part of the reagents were analytical reagent, the water for the two water.

3.1 potassium chlorate.

3.2 hydrochloric acid (rho = 1.19g/mL).

3.3 nitric acid (rho = 1.42g/mL).

3.4 sulfate (rho = 1.84g/mL).

Hydrochloride 3.5 (6100).

3.6 nitric acid (11).

3.7 tartaric acid solution (100g/L).

3.8 copper standard stock solution. Weigh 0.2500g copper (mass fraction >=99.99%) placed in 250mL beaker, add 20mL nitrate Acid (3.6), cover the surface of the pan, over low heat until completely dissolved, remove, cool. The solution is transferred to 250mL volumetric flask, constant volume of water, mixed uniform. This copper-containing solution 1mL 1mg.

3.9 bismuth standard stock solution. Weigh 0.2500g bismuth (mass fraction >=99.99%) placed in 250mL beaker, add 20mL nitrate Acid (3.6), cover the surface of the pan, over low heat until completely dissolved, remove, cool. The solution is transferred to 250mL volumetric flask, add 25mL nitrate Acid (3.3) with water to volume, and mix. This solution 1mL bismuth-containing 1mg.

3.10 copper and bismuth mixed standard solution. Pipette 5.00mL copper standard stock solution (3.8) and bismuth 25.00mL standard stock solution (3.9) to 250mL flask, add 25mL of nitric acid (3.3) with water to volume, and mix. Per milliliter of solution containing copper 20µg, bismuth 100µg.

4 Instruments and equipment

Atomic absorption spectrometer, with bismuth, copper hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Sensitivity. consistent with measurements in a solution matrix solution, wherein the concentration of bismuth is no greater than 0.20µg/mL, wherein the concentration of Cu

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 1050.7-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 1050.7-2015

$90.00