YS/T 1050.10-2016Methods for chemical analysis of lead-antimony concentrate. Part 10: Determanation of thallium. Inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry (English PDF)
铅锑精矿化学分析方法 第10部分:铊量的测定 电感耦合等离子体质谱法和电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for YS/T 1050.10-2016 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
July 11, 2016
Implementation date
January 1, 2017
Scope
YS/T 1050.10-2016 is the English-translated version of 铅锑精矿化学分析方法 第10部分:铊量的测定 电感耦合等离子体质谱法和电感耦合等离子体原子发射光谱法.
YS/T 1050.10-2016 — This part of YS/T 1050 specifies the method for the determination of thallium in lead and antimony concentrates. This part is suitable for the determination of thallium in lead antimony concentrate, the method of determination is 0.0001% ~ 0.010%; Method 2 determination range 0.010% to 0.10%.
Found what you need?
Document preview — YS/T 1050.10-2016
National Standard of the People's Republic of China
- ICS
- 73.060
- Classification
- D 42
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method 1 Inductively Coupled Plasma Mass Spectrometry
- 2.1 Method Summary
- 2.2 Reagents
- 2.3 Instruments
Foreword
YS/T 1050 "lead antimony concentrate chemical analysis method" is divided into 10 parts.
- Part 1. Determination of lead content - Na2EDTA titration;
- Part 2. Determination of antimony content - Cerium sulfate titration;
- Part 3. Determination of arsenic content - Potassium bromate titration;
- Part 4. Determination of zinc content - Na2EDTA titration;
- Part 5. Determination of sulfur content - Weight method;
- Part 6. Determination of iron content - Cerium sulfate titration;
- Part 7. Determination of bismuth and copper content - Flame atomic absorption spectrometric method;
- Part 8. Determination of gold and silver;
Part 9. Determination of silver content - Flame atomic absorption spectrometric method.
Part 10. Determination of thallium content - Inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry.
This section is part 10 of the YS/T 1050.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.
This part of the main drafting unit. Beijing Nonferrous Metals Research Institute.
This part participates in the drafting unit. Beijing Mining and Metallurgy Research Institute, Ningbo Entry-Exit Inspection and Quarantine Bureau, Kunming Metallurgical Research Institute, Zijin Mining Group Co., Ltd., China Nonferrous Guilin Mineral Geology Research Institute Co., Ltd., Bayuquan Entry-Exit Inspection and Quarantine Bureau, Nantong Entry-Exit Inspection and Inspection Epidemic Bureau, Fangchenggang Entry - Exit Inspection and Quarantine Bureau.
1 Scope
This part of YS/T 1050 specifies the method for the determination of thallium in lead and antimony concentrates.
This part is suitable for the determination of thallium in lead antimony concentrate, the method of determination is 0.0001% ~ 0.010%; Method 2 determination range 0.010% to 0.10%.
2 Method 1 Inductively Coupled Plasma Mass Spectrometry
2.1 Method Summary
Samples of hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid dissolved, hydrogen bromide volatile in addition to antimony. To iridium as the internal standard, in the hydrochloric acid medium, with the inductance coupling Determination of Thallium by Plasma Mass Spectrometry.
2.2 Reagents
Unless otherwise stated, only reagents and primary water identified as excellent grade were used in the analysis.
2.2.1 Hydrochloric acid (rho1.19g/mL).
2.2.2 nitric acid (rho1.42g/mL).
2.2.3 Hydrofluoric acid (rho1.15g/mL).
2.2.4 perchloric acid (rho1.67g/mL).
2.2.5 hydrobromic acid (rho1.49g/mL).
2.2.6 Thallium standard storage solution. Weigh 0.1000g metal thallium (wTl >= 99.99%) in 100mL beaker, add 50mL hydrochloric acid (2.2.1) dissolved, into the 1000mL volumetric flask, diluted with water to the mark, mix. This solution 1mL thallium containing 100µg.
2.2.7 Thallium standard solution A. Remove 10.00mL thallium standard storage solution (2.2.6) In a 100mL volumetric flask, add 5mL hydrochloric acid (2.2.1), diluted with water to the mark, mix, this solution 1mL thallium containing 10µg.
2.2.8 Thallium standard solution B. Remove 10.00mL thallium standard solution (2.2.7) In a 100mL volumetric flask, add 5mL hydrochloric acid (2.2.1) Diluted with water to the mark, mix, this solution 1mL thallium containing 1µg.
2.2.9 iridium standard storage solution. Weigh 0.1000g iridium powder (wIr >= 99.99%), placed in 50mL glass tube, add 8mL hydrochloric acid (2.2.1), 2 mL of hydrogen peroxide, and sealed. Dissolved at 150 ° C for 48 h, cooled and opened. The tube test solution was washed into a 100 mL volumetric flask, Add 10mL hydrochloric acid (2.2.1), diluted with water to the mark, mix. This solution 1mL containing 1000µg iridium.
2.2.10 iridium internal standard solution. remove the 1.00mL iridium standard storage solution (2.2.9) in a 1000mL volumetric flask, add 50mL hydrochloric acid (2.2.1), diluted with water to the mark, mix well. This solution 1mL containing 1µg iridium.
2.3 Instruments
2.3.1 inductively coupled plasma mass spectrometer, the instrument quality resolution is better than (0.8 ± 0.1) amu.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
How to Download YS/T 1050.10-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 1050.1-2015 — Methods for chemical analysis of lead antimony concentrates - Part 1: Determination of lead content - Na2EDTA titration method
YS/T 1050.2-2015 — Methods for chemical analysis of lead antimony concentrates. Part 2: Determination of antimony content. Cerium sulfate titration method
YS/T 1050.3-2015 — Methods for chemical analysis of lead antimony concentrates. Part 3: Determination of arsenic content. The potassium bromate titration method
Secure payment via Stripe
Payments accepted
YS/T 1050.10-2016