YS/T 1050.1-2015Methods for chemical analysis of lead antimony concentrates - Part 1: Determination of lead content - Na2EDTA titration method (English PDF)
铅锑精矿化学分析方法 第1部分:铅量的测定 Na2EDTA滴定法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YS/T 1050.1-2015 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
April 30, 2015
Implementation date
October 1, 2015
Scope
YS/T 1050.1-2015 is the English-translated version of 铅锑精矿化学分析方法 第1部分:铅量的测定 Na2EDTA滴定法.
YS/T 1050.1-2015 — This section YS/T 1050 specifies the method for determination of lead-antimony concentrates of lead content. This section applies to the determination of the amount of lead in lead-antimony concentrate, the measurement range (mass fraction) was 14.00% ~ 34.00%.
Found what you need?
Document preview — YS/T 1050.1-2015
National Standard of the People's Republic of China
- ICS
- 73.060
- Classification
- D 42
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
- 3.11 Disodium edetate (Na2EDTA) Standard Solution
Foreword
YS/T 1050-2015 "Methods for chemical analysis of lead-antimony concentrate" is divided into the following nine sections.
--- Part 1. Determination of lead content Na2EDTA titration;
--- Part 2. Determination of antimony content cerium sulfate titration;
--- Part 3. Determination of arsenic content potassium bromate titration;
--- Part 4. Determination of zinc contents Na2EDTA titration;
--- Part 5. Determination of sulfur content - Gravimetric method;
--- Part 6. Determination of iron content cerium sulfate titration;
--- Part 7. Determination of the amount of bismuth and copper - Flame atomic absorption spectrometry amount;
--- Part 8. gold and silver content determination fire assay;
--- Part 9. Determination of the amount of silver by flame atomic absorption spectrometry.
This is Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Guangxi Metallurgical Product Quality Supervision and Inspection Station.
This section is drafted. Guangxi China Tin Group Co., Ltd.
Participated in the drafting of this section. Beijing Mining Research Institute, Guangxi Zhuang Autonomous Region Analysis and Testing Center, China Certification & Inspection Group Ltd., Guangxi, Guilin University of Technology.
1 Scope
This section YS/T 1050 specifies the method for determination of lead-antimony concentrates of lead content.
This section applies to the determination of the amount of lead in lead-antimony concentrate, the measurement range (mass fraction) was 14.00% ~ 34.00%.
2 Method summary
Sample by sulfuric acid, nitric acid is dissolved, remove arsenic, antimony and tin with hydrobromic acid. Lead to lead sulfate precipitation and other interfering elements separated precipitate Dissolved in a pH value of 5.5 to 6.0 acid - sodium acetate buffer solution, with xylenol orange as indicator, titrate with standard Na2EDTA to the solution from purple turns bright yellow as the end point.
3 Reagents
Unless otherwise indicated, this part of the reagents were analytical reagent, the water for the two water.
3.1 metallic lead (Pb mass fraction >=99.99%).
3.2 sodium fluoride.
3.3 sulfate (rho = 1.84g/mL).
3.4 nitric acid (rho = 1.42g/mL).
3.5 hydrobromide (rho = 1.49g/mL).
3.6 ethanol.
3.7 ascorbic acid.
3.8 nitric acid (19).
3.9 sulfate wash (298).
3.10 acetic acid - sodium acetate buffer solution. Weigh 200g of sodium acetate [CH3COONa · 3H2O] was dissolved in water, was added 10mL of glacial acetic acid, Diluted with water to 1000mL, and mix.
3.11 Disodium edetate (Na2EDTA) Standard Solution
3.11.1 Formulated
2.86gNa2EDTA weighed in a beaker, add water, dissolved by heating, cooling filtration and transferred to 1000mL volumetric flask with water Dilute to volume, mix, after placing 1d calibration.
3.11.2 Calibration
Weigh 0.05g of metallic lead (3.1), accurate to 0.0001g, placed triangle 250mL beaker, add 15mL sulfuric acid (3.3), 5mL Nitric acid (3.4), placed on the high-temperature furnace heated to white smoke vacated. 5.4.2 - 5.4.5 by the following conduct.
Along with the calibration blank test.
The actual concentration Na2EDTA standard titration solution according to formula (1).
(V2-V1) × 10-3 × 207.19 (1)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download YS/T 1050.1-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 1050.10-2016 — Methods for chemical analysis of lead-antimony concentrate. Part 10: Determanation of thallium. Inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry
YS/T 1050.2-2015 — Methods for chemical analysis of lead antimony concentrates. Part 2: Determination of antimony content. Cerium sulfate titration method
YS/T 1050.3-2015 — Methods for chemical analysis of lead antimony concentrates. Part 3: Determination of arsenic content. The potassium bromate titration method