Scope

YD/T 777-2006 (Inversion equipment for telecommunications) is available as an English-translated PDF.

YD/T 777-2006 — This Standard specifies the technical conditions, test methods, and inspection rules of the DC-AC sine wave inversion equipment for telecommunications (hereinafter referred to as "inversion equipment"), which are required for accommodating the special requirements for communication equipment.

This Standard applies to the sine wave inversion equipment providing power supply for the communication equipment.

Found what you need?

Document preview — YD/T 777-2006

National Standard of the People's Republic of China

Issued by: The Ministry of Industry and Information Technology of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Definitions...6
  • 4 Product classification...7
  • 5 Requirements...8
  • 6 Test methods...15
  • 7 Inspection rules...23
  • 8 Marks, packaging, transportation and storage...25
  • Appendix A...26
  • Appendix B...27
  • Appendix C...30

Foreword

This Standard replaces YD/T 777-1999 Inversion equipment for

telecommunications.

Compared with the YD/T 777-1999, this Standard has the following major

changes.

— This Standard is drafted according to the format requirements specified

in the GB/T 1.1-2000.

— DELETE the reference to the GB 7260.

— ADD the definition "3.7 Peak factor".

— REVISE "4.1.3.1" of the original version. ADD "1.5" and "4" to this

Standard.

— REVISE "5.2" of the original version. MODIFY the allowable variation

range of the input voltage to 40 ~ 57.6V.

— DELETE "5.2.2" of the original version.

— REVISE the contents in the "5.4.2" of the original version. MODIFY the

"power factor 0.7" to "power factor 0.8" in Note 2 of the table. DECREASE

the AC output current rating.

— REVISE the contents in the "5.4.8" of the original version. STIPULATE

the AC output frequency rating as 50Hz. SEE 5.4.7 of this version.

— REVISE "5.4.9" of the original version. CANCEL the restriction of "2MHz".

SEE 5.4.8 of this version.

— REVISE the headline of the "5.4.12" of the original version. MODIFY the

"conversion mode" to the "conversion time". SEE 5.4.11 of this version.

— REVISE the contents in the "5.4.13" of the original version. ADD the input

requirements for inrush starting current. SEE 5.4.12 of this version.

— REVISE "5.4.14" of the original version. MODIFY the sentences. SEE

5.4.13 of this version.

— REVISE the contents in the "5.4.15" of the original version. MAKE the

grading rules for overload capacity. SEE 5.4.14 of this version.

— DELETE the requirements for temperature rise specified in the "5.4.16"

Inversion equipment for telecommunications

1 Scope

This Standard specifies the technical conditions, test methods, and inspection

rules of the DC-AC sine wave inversion equipment for telecommunications

(hereinafter referred to as "inversion equipment"), which are required for

accommodating the special requirements for communication equipment.

This Standard applies to the sine wave inversion equipment providing power

supply for the communication equipment.

2 Normative references

The provisions in the following documents become the provisions of this

Standard through reference in this Standard. For dated references, the

subsequent amendments (excluding corrections) or revisions do not apply to

this Standard. However, parties who reach an agreement based on this

Standard are encouraged to study if the latest versions of these documents are

applicable. For undated references, the latest versions apply to this Standard.

GB/T 191 Packaging – Pictorial marking for handling of goods

GB/T 2423.1-2001 Environmental testing for electric and electronic products

– Part 2.Test methods – Tests A. Cold

GB/T 2423.2-2001 Environmental testing for electric and electronic products

– Part 2.Test methods – Tests B. Dry heat

GB/T 2423.9-2001 Environmental testing for electric and electronic products

– Part 2.Test methods – Test Cb. Damp heat, steady state, primarily for

equipment

GB/T 2829-2002 Sampling procedures and tables for periodic inspection by

attributes (Apply to inspection of process stability)

GB/T 3047.1 Series of basic dimensions of panels, rack and cabinets for

vertical increment of 20mm

GB/T 3859.2 Semiconductor convertors – Application guide

GB/T 3873 General specifications for products packaging of communication

equipment

3.7 Peak factor

It refers to the ratio OF the peak value of the periodic load current TO its

effective value, which is generally used for measuring the inversion equipment's

ability of carrying non-linear loads.

3.8 Total harmonic distortion (THD)

It refers to the percentage OF the root mean square value of the distortion

content TO that of the fundamental component in the AC quantity.

3.9 Harmonic content

It refers to the value obtained after the fundamental component is subtracted

from the AC quantity.

Note. Harmonic content can be expressed as time functions or root mean square values.

4 Product classification

4.1 Product types, specifications and series

4.1.1 Product types

a) Single-phase sine wave inversion equipment;

b) Three-phase sine wave inversion equipment;

c) Redundant single-phase or three-phase sine wave inversion equipment in

parallel.

4.1.2 Input voltage rating series

SELECT 48V from the following numerical values as the DC input voltage rating

of inversion equipment.

Note. After the user puts forward the requirement and negotiates with the manufacturer, the products

beyond the above numerical values can also be produced.

4.1.3 Output power rating series (in unit of kVA)
4.1.3.1 Single-phase sine wave inversion equipment or single-phase

sine wave inverter unit

0.5, 1, 1.5, 2, 3, 4, 5 and 10.

Note. After the user puts forward the requirement and negotiates with the manufacturer, the products

from the heat sources.

5.1.2 Special operating conditions

If it is necessary to use the inverter under the conditions which are different

from the normal operating conditions specified in the Section 5.1.1, the user

shall put forward when placing orders, and shall make an agreement with the

manufacturer. For instance.

a) The inversion equipment used in abnormal mechanical stress, such as

vehicular communication;

b) The inversion equipment operating in tropical climates with high humidity and

high temperature;

c) The inversion equipment used in the environments where the atmospheric

pressure exceeds the range of 86kPa ~ 106kPa;

d) Marine inversion equipment, or the inversion equipment operating in

maritime climates.

5.2 Input conditions of DC power supplies

The DC input voltage is 48V. The allowable variation range is 40V~ 57.6V.

Note. After the user puts forward the requirement and negotiates with the manufacturer, the inversion

equipment beyond the above numerical values can also be produced.

5.3 Input conditions of AC power supplies

The inversion equipment can be provided with bypass power supply devices.

The AC power supplies providing power supply for the bypass devices shall

conform to the following requirements.

a) The allowable variation range of AC voltage shall be 85% to 110% of the

rated value;

b) The frequency rating and the allowable deviation of AC voltage shall be

respectively 50Hz and ± 5%;

c) The unbalance degree of three-phase AC voltage shall not be greater than

10%;

d) The phase deviation of three-phase AC voltage shall not be greater than 5°

electrical degree.

Note. After the user puts forward the requirement and negotiates with the manufacturer, the products

beyond the above numerical values can also be produced.

Table 2 Conduction Disturbance Limits of AC Output Voltage

Frequency range (MHz) Limits dB (µV) Quasi-peak Mean value

0.15~0.5 79 66

0.5~30 73 60

5.4.5 Unbalance degree of three-phase output voltage

During the nominal voltage input, and under the load conditions specified in the

specific product standards, the unbalance degree of three-phase output voltage

shall not be greater than 5%.

5.4.6 Phase deviation of three-phase output voltage

During the nominal voltage input, and under the load conditions specified in the

specific product standards, the phase deviation of three-phase output voltage

shall not be greater than 5° electrical degree.

5.4.7 Output frequency ratings and stabilizing accuracy

The AC output frequency rating is 50Hz. When the input voltage and load

current (resistive load) are within the allowable variation range, the stabilizing

accuracy of the output frequency shall not be greater than ± 2%.

5.4.8 Reflected wide band noise current at the input

When the input voltage, output voltage, and output current (resistive load)

operate at rated values, the wide band noise component in the DC current (root

mean square value) shall be less than 10% of the DC current.

5.4.9 Reflected relative psophometrically weighted noise current at the

input

When the input voltage, output voltage, and output current (resistive load)

operate at rated values, the reflected relative psophometrically weighted noise

current at the input s...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

How to Download YD/T 777-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YD/T 777-2006

$135.00