YD/T 1644.1-2007Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close p (English PDF)

Preview PDF

Also coversYDT1644.1-2007

This is a limited preview

Buy now to download the full PDF (52 pages)

Need quotation for your management?

Get a formal quotation for YD/T 1644.1-2007 in 30 minutes.

Issued by

Ministry of Industry Information Technology, the People’s Republic of China 3.No action is required - Full-cop

Level / Type

National · Recommended

Issue date

July 20, 2007

Implementation date

December 1, 2007

Scope

YD/T 1644.1-2007 (Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close p) is available as an English-translated PDF.

YD/T 1644.1-2007 — This Standard defines the procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear.

It applies to any electromagnetic field (EMF) transmitting device intended to be used with the radiating part of the device in close proximity to the human head and held against the ear, including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3 GHz.

The objective of this Standard is to specify the measurement method for demonstration of compliance with the specific absorption rate (SAR) limits for such devices.

The standard is about the measurement method, rather than the safety thresholds.

Found what you need?

Document preview — YD/T 1644.1-2007

National Standard of the People's Republic of China

Issued by: Ministry of Industry Information Technology, the People’s Republic of China 3.No action is required - Full-cop

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative references...4
  • 3 Terms and definitions...4
  • 4 Symbols and abbreviated terms...15
  • 5 Measurement system specifications...16
  • 6 Protocol for SAR assessment...22
  • 7 Uncertainty estimation...32
  • 8 Measurement report...50
  • Annex A (normative) Phantom specifications...52

Foreword

This Standard is one of Human exposure to radio frequency fields from hand-held and

body-mounted wireless communication devices Part Standard, and its name and it is consist

of the following parts.

1 Human exposure to radio frequency fields from hand-held and body-mounted wireless

communication devices - Human models, instrumentation, and procedures - Part 1.

Procedure to determine the specific absorption rate (SAR) for hand-held devices used in

close proximity to the ear (frequency range of 300 MHz to 3 GHz)

2 Human exposure to radio frequency fields from hand-held and body-mounted wireless

communication devices - Human models, instrumentation, and procedures - Part 1.

Procedure to determine the specific absorption rate (SAR) for hand-held devices used in

close proximity to the ear (frequency range of 300 MHz to 6 GHz)

This Standard is equivalent to IEC 62209-1 (2005). Human exposure to radio frequency

fields from hand-held and body-mounted wireless communication devices - Human models,

instrumentation, and procedures - Part 1.Procedure to determine the specific absorption rate

(SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz

to 3 GHz).

This Standard is Part 1.

Appendix A, B, C and D are normative appendixes, Appendix E, F, G, H, I and J are

informative appendixes.

This Standard is proposed and managed by China Communication Standardization

Association.

This Standard is prepared by MIIT Telecommunication Institute.

This Standard is written by. Wang Hongbo, Wang Nana, Qi Dianyuan, Wu Tongning,

and Wun Qian.

HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM

HAND-HELD AND BODY-MOUNTED WIRELESS COMMUNICATION

DEVICES – HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES

Part 1.Procedure to determine the specific absorption rate (SAR) for

hand-held devices used in close proximity to the ear (frequency range

of 300 MHz to 3 GHz)

1 Scope

This Standard defines the procedure to determine the specific absorption rate (SAR) for

hand-held devices used in close proximity to the ear.

It applies to any electromagnetic field (EMF) transmitting device intended to be used

with the radiating part of the device in close proximity to the human head and held against the

ear, including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3

GHz.

The objective of this Standard is to specify the measurement method for demonstration

of compliance with the specific absorption rate (SAR) limits for such devices. The standard

is about the measurement method, rather than the safety thresholds.

2 Normative references

The following standards contribute to the stipulation of this specification after being

quoted. All the revision versions (excluding correction version) of the quoted standards

specified with date are not applicable for this Standard. However, parties that have come to

agreements based on this Standard are encouraged to explore the possibility to use the latest

versions of the following standards. The latest version of the quoted documents without date

specified is applicable for this specification.

ISO/IEC Guide. 1995, Guide to the Expression of Uncertainty in Measurement

ISO/IEC 17025.1999, General requirements for the competence of testing and

calibration laboratories

3 Terms and definitions

For the purposes of this Standard, the following terms and definitions apply.

3.1

attenuation coefficient

numerical factor intended to account for attenuation due to the human head or body

tissue between the source and a specified point.

3.2

average (temporal) absorbed power

value of the time-averaged rate of energy transfer given by.

Where

- is the average power in watts.

t1 - is the start time of the exposure in seconds;

t2 - is the stop time of the exposure in seconds;

t2 – t1 - is the exposure duration in seconds;

P(t) - is the instantaneous absorbed power in watts;

3.3

axial isotropy

the maximum deviation of the SAR when rotating around the major axis of the probe

cover/case while the probe is exposed to a reference wave impinging from a direction along

the probe major axis.

3.4

basic restriction

restrictions on human exposure to time-varying electric, magnetic, and electromagnetic

fields that are based directly on established health effects.

NOTE. Within the frequency range of this Standard, the physical quantity used as a basic

restriction is the specific absorption rate (SAR).

3.5

boundary effect (probe)

A change in the sensitivity of an electric-field probe when the probe is located close to

(less than one probe-tip diameter) media boundaries.

3.6

wireless device shall be set to transmit at its highest power level for the conditions of use next to

the ear. The exposure tests shall be based on the functional and exposure characteristics of the test

devices, e.g., operating modes, antenna configurations, etc.

Whenever possible, final commercial product versions shall be tested using all normal

operational configurations, e.g., without any cables attached. Cables attached to a product are very

likely to alter the transmitter RF current distribution on metallic and conducting portions of the

product. Additionally, if tests are performed using prototypes, it shall be verified that the

commercial version has exactly the same mechanical and electrical characteristics as the tested

prototype. If this cannot be guaranteed, testing shall be repeated by sampling of unmodified

commercial product versions.

If operation of the DUT at the highest time-averaged power level is not possible, the test may

be performed at lower power and results then scaled to the maximum output power, provided that

the DUT SAR response is linear.

6.1.4 Position of the wireless device in relation to the phantom
6.1.4.1 General considerations

This Standard specifies two handset test positions against the head phantom – the "cheek"

position and the "tilt" position. These two test positions are defined in the following sub-clauses.

The handset should be tested in both of these positions on left and right sides of the SAM phantom.

If handset construction is such that the handset positioning procedures described in 6.1.4.2 and

6.1.4.3 to represent normal-use conditions cannot be used, e.g., some asymmetric handsets,

alternative alignment procedures should be adapted...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 52 pages — is available in the English PDF.

Referenced standards

How to Download YD/T 1644.1-2007

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
52 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YD/T 1644.1-2007

$550.00