YD/T 1644.1-2007Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close p (English PDF)
Also coversYDT1644.1-2007
This is a limited preview
Buy now to download the full PDF (52 pages)
Need quotation for your management?
Get a formal quotation for YD/T 1644.1-2007 in 30 minutes.
Issued by
Ministry of Industry Information Technology, the People’s Republic of China 3.No action is required - Full-cop
Level / Type
National · Recommended
Issue date
July 20, 2007
Implementation date
December 1, 2007
Scope
YD/T 1644.1-2007 (Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close p) is available as an English-translated PDF.
YD/T 1644.1-2007 — This Standard defines the procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear.
It applies to any electromagnetic field (EMF) transmitting device intended to be used with the radiating part of the device in close proximity to the human head and held against the ear, including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3 GHz.
The objective of this Standard is to specify the measurement method for demonstration of compliance with the specific absorption rate (SAR) limits for such devices.
The standard is about the measurement method, rather than the safety thresholds.
Found what you need?
Document preview — YD/T 1644.1-2007
National Standard of the People's Republic of China
Issued by: Ministry of Industry Information Technology, the People’s Republic of China 3.No action is required - Full-cop
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Terms and definitions...4
- 4 Symbols and abbreviated terms...15
- 5 Measurement system specifications...16
- 6 Protocol for SAR assessment...22
- 7 Uncertainty estimation...32
- 8 Measurement report...50
- Annex A (normative) Phantom specifications...52
Foreword
This Standard is one of Human exposure to radio frequency fields from hand-held and
body-mounted wireless communication devices Part Standard, and its name and it is consist
of the following parts.
1 Human exposure to radio frequency fields from hand-held and body-mounted wireless
communication devices - Human models, instrumentation, and procedures - Part 1.
Procedure to determine the specific absorption rate (SAR) for hand-held devices used in
close proximity to the ear (frequency range of 300 MHz to 3 GHz)
2 Human exposure to radio frequency fields from hand-held and body-mounted wireless
communication devices - Human models, instrumentation, and procedures - Part 1.
Procedure to determine the specific absorption rate (SAR) for hand-held devices used in
close proximity to the ear (frequency range of 300 MHz to 6 GHz)
This Standard is equivalent to IEC 62209-1 (2005). Human exposure to radio frequency
fields from hand-held and body-mounted wireless communication devices - Human models,
instrumentation, and procedures - Part 1.Procedure to determine the specific absorption rate
(SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz
to 3 GHz).
This Standard is Part 1.
Appendix A, B, C and D are normative appendixes, Appendix E, F, G, H, I and J are
informative appendixes.
This Standard is proposed and managed by China Communication Standardization
Association.
This Standard is prepared by MIIT Telecommunication Institute.
This Standard is written by. Wang Hongbo, Wang Nana, Qi Dianyuan, Wu Tongning,
and Wun Qian.
HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM
HAND-HELD AND BODY-MOUNTED WIRELESS COMMUNICATION
DEVICES – HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES
Part 1.Procedure to determine the specific absorption rate (SAR) for
hand-held devices used in close proximity to the ear (frequency range
of 300 MHz to 3 GHz)
1 Scope
This Standard defines the procedure to determine the specific absorption rate (SAR) for
hand-held devices used in close proximity to the ear.
It applies to any electromagnetic field (EMF) transmitting device intended to be used
with the radiating part of the device in close proximity to the human head and held against the
ear, including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3
GHz.
The objective of this Standard is to specify the measurement method for demonstration
of compliance with the specific absorption rate (SAR) limits for such devices. The standard
is about the measurement method, rather than the safety thresholds.
2 Normative references
The following standards contribute to the stipulation of this specification after being
quoted. All the revision versions (excluding correction version) of the quoted standards
specified with date are not applicable for this Standard. However, parties that have come to
agreements based on this Standard are encouraged to explore the possibility to use the latest
versions of the following standards. The latest version of the quoted documents without date
specified is applicable for this specification.
ISO/IEC Guide. 1995, Guide to the Expression of Uncertainty in Measurement
ISO/IEC 17025.1999, General requirements for the competence of testing and
calibration laboratories
3 Terms and definitions
For the purposes of this Standard, the following terms and definitions apply.
3.1
attenuation coefficient
numerical factor intended to account for attenuation due to the human head or body
tissue between the source and a specified point.
3.2
average (temporal) absorbed power
value of the time-averaged rate of energy transfer given by.
Where
- is the average power in watts.
t1 - is the start time of the exposure in seconds;
t2 - is the stop time of the exposure in seconds;
t2 – t1 - is the exposure duration in seconds;
P(t) - is the instantaneous absorbed power in watts;
3.3
axial isotropy
the maximum deviation of the SAR when rotating around the major axis of the probe
cover/case while the probe is exposed to a reference wave impinging from a direction along
the probe major axis.
3.4
basic restriction
restrictions on human exposure to time-varying electric, magnetic, and electromagnetic
fields that are based directly on established health effects.
NOTE. Within the frequency range of this Standard, the physical quantity used as a basic
restriction is the specific absorption rate (SAR).
3.5
boundary effect (probe)
A change in the sensitivity of an electric-field probe when the probe is located close to
(less than one probe-tip diameter) media boundaries.
3.6
wireless device shall be set to transmit at its highest power level for the conditions of use next to
the ear. The exposure tests shall be based on the functional and exposure characteristics of the test
devices, e.g., operating modes, antenna configurations, etc.
Whenever possible, final commercial product versions shall be tested using all normal
operational configurations, e.g., without any cables attached. Cables attached to a product are very
likely to alter the transmitter RF current distribution on metallic and conducting portions of the
product. Additionally, if tests are performed using prototypes, it shall be verified that the
commercial version has exactly the same mechanical and electrical characteristics as the tested
prototype. If this cannot be guaranteed, testing shall be repeated by sampling of unmodified
commercial product versions.
If operation of the DUT at the highest time-averaged power level is not possible, the test may
be performed at lower power and results then scaled to the maximum output power, provided that
the DUT SAR response is linear.
6.1.4 Position of the wireless device in relation to the phantom
6.1.4.1 General considerations
This Standard specifies two handset test positions against the head phantom – the "cheek"
position and the "tilt" position. These two test positions are defined in the following sub-clauses.
The handset should be tested in both of these positions on left and right sides of the SAM phantom.
If handset construction is such that the handset positioning procedures described in 6.1.4.2 and
6.1.4.3 to represent normal-use conditions cannot be used, e.g., some asymmetric handsets,
alternative alignment procedures should be adapted...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 52 pages — is available in the English PDF.
Referenced standards
Normative references
ISO/IEC 17025.1999
Cited by
- GB/T 46755-2025General technical requirements for intelligent textile products
- YD/T 1484.6-2013Measurement method for radiated RF power and receiver performance of wireless device. Part 6: LTE wireless device
- YD/T 2147-2010Test methods of Nx40Gbit/s optical wavelength division multiplexing (WDM) systems
How to Download YD/T 1644.1-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YD/T 1644.2-2011 — Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-human models, instrumentation, and procedures. Part 2: Procedure to determine the specific absorption rate(SAR) for wireless communication devices used
YD/T 6486-2025 — General assessment method of data set quality for artificial intelligence - Overall requirements
YD/T 1092-2023 — Telecommunication cables - Foamed polyolefin dielectric, corrugated copper-tube outer conductor, 50 Ohm radio-frequency coaxial cable for wireless communications
Secure payment via Stripe
Payments accepted
YD/T 1644.1-2007
$550.00