TB/T 2640-1995Structural Design for Fire Protection of Passenger Train (English PDF)

Preview PDF

Also coversTBT2640-1995

This is a limited preview

Buy now to download the full PDF (5 pages)

Need quotation for your management?

Get a formal quotation for TB/T 2640-1995 in 30 minutes.

Issued by

State Railway Administration

Level / Type

National · Recommended

Issue date

June 5, 2017

Implementation date

January 1, 2018

Scope

TB/T 2640-1995 (Structural Design for Fire Protection of Passenger Train) is available as an English-translated PDF.

TB/T 2640-1995 — This standard specifies the basic principles and protective technical requirements for the railway signaling equipment for over-voltage and over- current protection induced by lightning electromagnetic pulse.

This standard applies to the design, construction, manufacture and maintenance of the integrated lightning protection system for the newly built railway and for the reconstruction and expansion of existing railway signaling equipment.

The integrated lightning protection measures for the other electronic equipment system can refer to this standard. This standard does not consider the protection of the signaling equipment under direct lightning.

Found what you need?

Document preview — TB/T 2640-1995

National Standard of the People's Republic of China

ICS
45.020
Classification
S 60

Issued by: State Railway Administration

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and abbreviations...5

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard replaces TB/T 3074-2003 "Technical specification for protection

against lightning electromagnetic impulse on railway signaling equipment". In

addition to editorial changes, as compared with TB/T 3074-2003, the main

technical changes of this standard are as follows.

- MODIFY various factors of the lightning hazard risk to railway signaling

equipment (SEE 5.1; chapter 4 of the 2003 version);

- MODIFY the "Principles of lightning electromagnetic pulse protection for

signaling equipment system" into "Basic requirements of lightning

electromagnetic pulse protection for signaling equipment system" (SEE

chapter 4; chapter 5 of 2003 version);

- MODIFY the division of lightning protection zone (SEE chapter 4; chapter

6 of 2003 version);

- DELETE the improvement of the lightning electromagnetic pulse of

signaling equipment (SEE chapter 6 of 2003 version);

- ADD the external protection and internal protection of the signaling

equipment room (SEE 4.3, 4.5);

- ADD specific requirements and implementation methods for external and

internal protection of signaling equipment rooms (SEE 5.4.1);

- ADD the direct-attached continuous screening requirements for electronic

equipment rooms (SEE 5.4.2.3);

- MODIFY the requirements for the installation of coordinated SPD system

(SEE 5.4.3; chapter 8 of 2003 version);

- DELETE the "Test of protection level of lightning electromagnetic pulse of

signaling equipment" (SEE chapter 9 of 2003 version);

- MODIFY grounding requirements and technical parameters (SEE 5.4.1.3,

5.4.1.4; chapter 10 of 2003 version);

- MODIFY "Division of lightning protection zones and making of conformance

earth potential connections" (SEE 4.4, Figure 2; Appendix A of 2003

version);

- ADD "Determination of the scope of lightning protection" (SEE Appendix A);

Technical specification for protection against

lightning electromagnetic impulse on railway

signaling equipment

1 Scope

This standard specifies the basic principles and protective technical

requirements for the railway signaling equipment for over-voltage and over-

current protection induced by lightning electromagnetic pulse.

This standard applies to the design, construction, manufacture and

maintenance of the integrated lightning protection system for the newly built

railway and for the reconstruction and expansion of existing railway signaling

equipment. The integrated lightning protection measures for the other electronic

equipment system can refer to this standard.

This standard does not consider the protection of the signaling equipment under

direct lightning.

2 Normative references

The following documents are essential to the application of this document. For

the dated documents, only the versions with the dates indicated are applicable

to this document; for the undated documents, only the latest version (including

all the amendments) are applicable to this standard.

TB/T 2311 Surge protective devices for railway signal system

3 Terms and abbreviations

3.1 Terms

The following terms and definitions apply to this document.

3.1.1

Lightning electromagnetic impulse

3.1.13

Cable entrance earthing bar

A dedicated earthing bar connecting the cable steel jacket entering into the

machine room to the general earthing bar or ring grounding electrode at the

entrance.

3.1.14

Lightning equipotential bonding

To reduce the potential difference created by lightning current, a lightning

protection measure that connects the isolated conductive components

directly to the lightning protection system either directly or through a surge

protector.

3.1.15

Lightning protection device

Equipment used to limit lightning transient overvoltage AND to shunt

lightning surge currents.

3.1.16

SPD surge protective device

A lightning protection device to limit transient overvoltage AND to discharge

surge current, which contains at least one non-linear element.

Note 1. Surge protective device is also known as power protection cable,

lightning protection device, lightning protector, lightning arrester and so on.

Note 2. The surge protective device is divided into single port SPD and dual

port SPD.

3.1.17

Maximum continuous operating voltage

UC

The maximum AC voltage r.m.s. or dc voltage value that can be permanently

applied on the SPD of various protection modes.

3.1.18

3.1.23

Railway integrated earthing technology

A grounding system which connects the traction power supply, power supply,

signal and communication systems, buildings, road beds, platforms, bridges,

tunnels, sound barriers, etc., along the railway which require grounding

through the common earthing system.

3.1.24

Through-railway grounding wire

Grounding electrode laid along the railway to connect all kinds of equipment

and facilities, AND used as the auxiliary passage for the traction backflow.

3.2 Abbreviations

The following abbreviations apply to this standard.

CEEB. Cable Entrance Earthing Bar

EMC. Electro Magnetic Compatibility

ERP. Earthing Reference Point

LEMP. Lightning Electromagnetic impulse

LP. Lightning Protection

LPS. Lightning Protection System

LPZ. Lightning Protection Zone

PE. Protective Earthing

SPD. Surge Protection Device

SPM. Surge Protection Measure

a) External areas (the area outside the building in which the machine room

is directly exposed to the threat of thunder and lightning).

LPZ0. In this zone, the threat comes from an un-attenuated lightning

electromagnetic field. The system inside the machine room may suffer the

risk of all or part of the lightning surge current. LPZ0 is further divided into

the following two categories.

LPZ0A. Direct lightning non-protection zone, it is the space that can

withstand the direct lightning and the entire lightning electromagnetic field,

the internal system may suffer all the lightning surge current hazards.

LPZ0B. Direct lightning protection zone, it is a space that protects the direct

lightning BUT still can suffer all the lightning electromagnetic field. Internal

systems may suffer the hazards of some lightning surge currents.

b) Internal area (the area inside the building in which the machine room is

not directly exposed to the threat of thunder and lightning), there may be

multi-layer zoning.

LPZ1. The lightning surge current in this zone is limited by the on-boundary

shunt and SPD. Space shielding can attenuate lightning electromagnetic

field.

LPZ2... n. The lightning surge in the circuit is further shunted at the

boundary and limited by the SPD on the boundary, the lightning

electromagnetic field is further attenuated by the boundary space shielding.

4.5 The signal room shall be integrated into the machine room building

synthetical protection system. As for the signaling equipment in the interval and

station which is exposed to the lightning environment, it shall take the following

lightning protection measures.

a) The signaling equipment shall be placed in the chamber and box with the

shield grounded;

b) The cable shielding leading into the machine room shall be grounded;

c) Cable and equipment interface are reasonably equipped with SPD or other

lightning protection equipment;

d) The conventional arresting device is provided at the location where the

signaling equipment is concentrated, to include the signaling equipment

into the direct lightning protection scope.

5 Synthetical lightning protection of signal room

5.1 Lightning risk factors of signaling equipment

The lightning risk of railway signaling equipment is related to the following

factors.

a) The meteorological conditions such as lightning parameters along the

railway line and the location of the station and machine room;

b) Topography and geology of the area where the protected building is

located;

c) Characteristics and surroundings of signal room buildings or groups of

buildings, structures (brick, reinforced concrete, steel frame, metal facade,

etc.), building dimensions (length, width, height and location distribution),

types of roofing materials, height of the adjacent building;

d) Distribution of electronic information system equipment on all floors in the

building;

e) The type, function and performance parameters (such as working

frequency, power, working level, transmission rate, characteristic

impedance, transmission medium and interface type) of the protected

equipment in the signal room, the structure of the communication network,

the electrical connection and signal transmission method between

different equipment, lightning withstanding capacity Uw at each port, etc.;

f) Power supply and distribution, AND the grounding type of power

distribution system.

The above factors shall be considered before taking the synthetical lightning

protection measures for railway signaling equipment.

5.2 Signal room location selection

5.2.1 When the signal room is set up separately, the signal r...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

Referenced standards

Normative references

TB/T 2311

How to Download TB/T 2640-1995

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

TB/T 2640-1995

$120.00