Scope

T/CSAE 86-2018 is the English-translated version of 电动汽车锂离子电池箱火灾防控装置 性能要求和试验方法.

T/CSAE 86-2018 — This standard specifies the performance requirements and test methods for automatic fire extinguishing devices for lithium-ion battery cases in electric vehicles.

This standard applies to the design, layout and testing of fire extinguishing devices.

Found what you need?

Document preview — T/CSAE 86-2018

National Standard of the People's Republic of China

Classification
T 47

Issued by: China Society of Automotive Engineers

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 Lithium ion battery box lithium-ion battery box
  • 3.2 Fire extinguishing device fire extinguishing device
  • 3.3 Start time starting time
  • 3.4 Injection time discharging time
  • 4 Model preparation
  • 4.1 Model preparation method
  • 4.2 Model Tag Example
  • 5 Requirements
  • 5.1 Basic requirements
  • 5.2 Appearance and logo
  • 5.3 Power supply
  • 5.4 Detection alarm
  • 5.5 Start running
  • 5.6 Compatibility
  • 5.7 Fault alarm
  • 5.8 Start feedback
  • 5.9 Fire extinguishing performance
  • 6 Test methods
  • 6.1 High temperature test
  • 6.2 Low temperature test
  • 6.3 Vibration, mechanical shock, temperature shock, wet heat cycle test
  • 6.4 Electromagnetic compatibility test
  • 6.5 Fire test

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

Some elements of this standard may involve patents, and the standard issuing authority does not assume responsibility for identifying these patents.

This standard was proposed by the Technical Innovation Alliance of the Electric Vehicle Industry.

This standard was drafted. Shanghai Fire Research Institute of the Ministry of Public Security, Hangzhou Zhongchuan Fire Equipment Co., Ltd.

1 Scope

This standard specifies the performance requirements and test methods for automatic fire extinguishing devices for lithium-ion battery cases in electric vehicles.

This standard applies to the design, layout and testing of fire extinguishing devices.

2 Normative references

The following standards are essential for the application of this document. All dated references, all subsequent modifications (not the inclusion of errata content or revisions does not apply to this specification, but parties to agreements based on this specification are encouraged to study the use of these documents.

The possibility of the latest version.

GB 2423.1 Environmental testing of electrical and electronic products - Part 2. Test methods Test A. Low temperature GB 2423.2 Environmental testing of electrical and electronic products - Part 2. Test methods Test A. High temperature GB/T 31467.3 Lithium-ion battery packs and systems for electric vehicles - Part 3 - Safety requirements and test methods GB 7258 Motorcycle Operation Safety Technical Conditions QC/T 413-2015 Basic technical conditions for automotive electrical equipment

3 Terms and definitions

3.1 Lithium ion battery box lithium-ion battery box

An energy storage device box with a plurality of lithium ion battery cells or modules, usually including a lithium ion battery module, a battery management module, the cabinet and corresponding accessories are referred to as lithium ion battery boxes.

3.2 Fire extinguishing device fire extinguishing device

Electric vehicle lithium-ion battery box automatic fire extinguishing device (hereinafter referred to as "fire extinguishing device") consists of measurement and control module, acquisition module, fire extinguishing the composition of the tank, the nozzle, the connecting pipe fitting and the main control unit are used to suppress the initial loss of the lithium ion battery due to the thermal runaway of the battery.

Burning and exploding.

3.3 Start time starting time

The time from when the fire extinguishing device receives the detection signal to the action of the fire extinguisher tank.

2T/CSAE 86 -.2018

3.4 Injection time discharging time

After the fire extinguishing device is started, the time when the fire extinguishing agent is ejected from the nozzle to the time when the spouting is stopped.

4 Model preparation

4.1 Model preparation method

4.2 Model Tag Example

The model of a gas fire extinguishing device with a storage pressure of 1.0 MPa and a mass media of 0.48 kg is expressed as EVMQ0.48/1.0.

5 Requirements

5.1 Basic requirements

5.1.1 The fire extinguishing device shall be able to work normally in an environment with a temperature of -20 ° C to + 60 ° C.

5.1.2 The wiring harness used in the fire extinguishing device shall comply with the requirements of GB 7258.

5.1.3 Fire-resistant devices and accessories shall be subjected to vibration, mechanical shock, temperature shock and damp heat cycle to meet the requirements of GB/T 31467.3.

5.1.4 The requirements for electromagnetic compatibility of fire-extinguishing devices shall meet the requirements of item 3.9 of QC/T 413-2015.

5.1.5 The extinguishing agent shall be a qualified product permitted by the State and shall comply with the relevant national standards and industry standards.

5.2 Appearance and logo

5.2.1 Each component of the fire extinguishing device shall have no obvious processing defects or mechanical damage, and the outer surface of the component shall be treated with anti-corrosion treatment and anti-corrosion.

The coating and plating should be complete and uniform.

5.2.2 The nameplate of the fire extinguishing device shall be firmly placed in the obvious part of the device, indicating. device name, model specification, and implementation standard Code, working temperature range, production unit, equipment number, production date, etc.

5.3 Power supply

5.3.1 The nominal voltage of the fire extinguishing device shall be 12 Vd.c or 24 Vd.c, the monitoring current shall not exceed 100 mA, and the working current shall not be customize Storage pressure in megapascals (MPa) Extinguishing agent quality in kilograms (kg) Type of extinguishing agent (Q stands for gas, F stands for dry powder, R stands for hot aerosol, S stands for other) Electric vehicle lithium ion battery box automatic fire extinguishing device - -XXXEVM - -/3T/CSAE 86 -.2018 should be greater than 2 A, power should not be greater than 30 W.

5.3.2 The fire extinguishing device shall have a rechargeable standby power supply, and the standby power supply capacity shall be capable of continuous operation for 24 hours under normal monitoring conditions.

The system should be guaranteed to start reliably during the period.

5.3.3 The main and standby power supply of the fire extinguishing device shall have working instructions.

5.4 Detection alarm

5.4.1 Fire-extinguishing device detectors shall comply with the relevant national standards or industry standards.

5.4.2 The fire extinguishing device shall be able to receive the fire alarm signal of the fire detector and emit an audible and visual alarm signal, and comply with the provisions of GB 7258.

5.5 Start running

5.5.1 Fire extinguishing devices shall have automatic start and manual start functions.

5.5.2 The starting time of the fire extinguishing device should not exceed 3 s.

5.5.3 The fire-fighting device should not be sprayed for more than 10 s.

5.5.4 Manual start should have effective measures to prevent malfunction and indicate the operation method with text or graphic symbols.

5.5.5 The start-up of the fire-extinguishing device shall have a self-holding function, no need for continuous power supply, and the instantaneous energization time shall not exceed 1 s.

5.6 Compatibility

After the fire extinguishing agent is sprayed into the battery box for 24 hours, there is no corrosion on the surface of the battery, and the battery should be able to charge and discharge normally.

5.7 Fault alarm

The fire extinguishing device shall have automatic patrol inspection, pressure leakage, line connection fault alarm function, and shall be able to issue a fault alarm when the fault occurs.

signal.

5.8 Start feedback

The fire extinguishing device shall have a start feedback alarm function.

5.9 Fire extinguishing performance

5.9.1 In the test chamber described in 6.5.1, when the fire extinguishing device is started, if there is an open flame, the device receives the application letter.

The fire should not be extinguished for more than 30 s, and should not re-ignite within 10 minutes, and the temperature of the battery test chamber should not exceed 150 °C.

5.9.2 When the fire extinguishing device is started, if there is no open flame, the device should have no open flame within 10 minutes after receiving the application signal, and the battery test the temperature at the temperature of the inspection box should not exceed 150 °C.

5.9.3 There should be no open flame outside the battery test chamber.

5.9.4 The relative pressure in the battery test chamber should not exceed 50 kPa.

4T/CSAE 86 -.2018

6 Test methods

6.1 High temperature test

The fire extinguishing device shall be tested at a high temperature in accordance with the method specified in GB/2432.2, and the results shall comply with the requirements of 5.1.1.

6.2 Low temperature test

The fire extinguishing device shall be tested at a low temperature in accordance with the method specified in GB/2432.1, and the results shall comply with the requirements of 5.1.1.

6.3 Vibration, mechanical shock, temperature shock, wet heat cycle test

Fire extinguishing devices and fittings shall be tested in accordance with the method specified in GB/T 31467.3, and the results shall comply with the requirements of 5.1.3.

6.4 Electromagnetic compatibility test

The fire extinguishing device shall be tested in accordance with the method specified in QC/T 413-2015, and the results shall comply with the requirements of 5.1.4.

6.5 Fire test

Unless otherwise specified, the test shall be at a temperature of 25 ± 5 ° C, a relative humidity of 15% to 90%, and an atmospheric pressure of 86 kPa to 106 kPa.

In the environment.

6.5.1 Test chamber

The fire test chamber shall be a lithium ion battery box model measuring 1000 mm × 800 mm × 300 mm. The test chamber shall be carried out as much as possible.

Small modifications to achieve connection to fire extinguishing devices and electrostatic igniters.

6.5.2 Lithium-ion battery

At least the lithium iron phosphate battery module and the ternary lithium battery module should be used as test objects to conduct fire extinguishing tests, lithium ion battery modules.

The group should be charged to the rated voltage and connected by means of 12S2P.

6.5.3 Test method

6.5.3.1 Fix a lithium-ion battery module in the middle of the test chamber; fill the test chamber with non-combustible material to the net volume for testing Check the box volume by 20% to simulate the real lithium-ion battery pack as much as possible; connect the test chamber and the fire extinguishing device.

6.5.3.2 Determining the fire triggering object. Select a single battery that can be fire triggered by one of the methods in 6.5.3.3 for the trigger object, the heat generated by the thermal trigger of the fire trigger object should be easily transferred to the adjacent battery. For example, choose to store electricity A single battery that is closest to the center in the pool, or a single battery that is surrounded by other cells and is difficult to generate heat radiation.

6.5.3.3 Overcharge or heating should be selected as the trigger mode for the fire test.

a) Overcharge trigger mode. connect extra wires on the trigger object to achieve overcharge, to a minimum of 1/3C, the maximum does not exceed the battery the manufacturer specifies a maximum current for the normal operating range to charge the trigger object with constant current.

5T/CSAE 86 -.2018

b) Heating trigger mode. use a flat or rod-shaped heating device, and its surface should be covered with ceramic, metal or insulating layer.

For the same block heating device as the single battery, the heating device can be used to replace one of the single cells;

A block heating device smaller than a single battery can be installed in the module and directly in contact with the surface of the triggering object;

The membrane heating device should always be attached to the surface of the triggering object; wherever possible, the heating area of the heating device it should not be larger than the surface area of the battery; the heating surface of the heating device should be in direct contact with the surface of the battery, and the position of the heating device should be the position of the temperature sensor specified in 6.5.4 corresponds; the trigger object should be heated with a heating power of 30 W to 1000 W.

6.5.3.4 Complete the arrangement using one of the trigger modes specified in 6.5.3.3, and place the electrostatic ignition head in the two poles of the trigger object.

Close the test box at 100mm directly above the point.

6.5.3.5 Pump the test chamber to a vacuum of less than 667 Pa, stop the pump, and the pressure drop within 5 min shall not exceed 267 Pa to ensure the test chamber is dense.

Good sealing.

6.5.3.6 Restore the pressure in the test chamber to normal pressure and start the electrostatic igniter. The voltage of the electrostatic igniter is 10 kV, with a period of 1 s.

Continue to ignite, start the heating device or start charging until the fire extinguishing device is activated.

6.5.3.7 After the fire extinguishing agent is applied, the test chamber should be closed for at least 15 minutes. The result should meet the requirements of 5.9.

6.5.4 Monitoring of temperature and pressure

6.5.4.1 Arrange the temperature measurement points as specified in Figure 1. The sampling interval of the temperature data should be less than 1 s, and the accuracy requirement is ±1 °C.

The diameter of the temperature sensor tip should be less than 1 mm.

6.5.4.2 Pressure measuring points shall be placed in the test chamber to facilitate the location of the fire test.

Figure 1 Schematic diagram of the arrangement of the temperature sensor when the heating is triggered

Hard and soft battery cylindrical battery -I cylindrical battery-II heating equipment Heating device (resistance wire) Temperature monitor connection

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download T/CSAE 86-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

T/CSAE 86-2018

$263.00