SN/T 5248-2020 is the English-translated version of 进口载金树脂物料中金含量的测定方法 火焰原子吸收光谱法.

SN/T 5248-2020 — This standard specifies the atomic absorption spectrometry method for the determination of gold content in gold-loaded resin materials. This standard applies to the determination of gold content in gold-loaded resin materials.

Found what you need?

Document preview — SN/T 5248-2020

National Standard of the People's Republic of China

ICS
83.020
Classification
G 31

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 Reagents and materials
  • 5 Apparatus and equipment
  • 6 Sample
  • 7 Analysis steps
  • 7.1 Sample processing
  • 7.2 Blank test
  • 7.3 Production of working curve
  • 7.4 Determination
  • 8 Result calculation
  • 9 Precision

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed and managed by the General Administration of Customs of the People's Republic of China.

Drafting organizations of this standard. Urumqi Customs of the People's Republic of China, Shanghai Tuomi Testing Technology Service Co., Ltd., Xinjiang Agriculture University College of Chemical Engineering, Beilun Customs of the People's Republic of China, Xinjiang Shuiqingqing Environmental Monitoring Technology Service Co., Ltd., Xinjiang Uyghur Autonomous Region Analysis and Testing Research Institute, Tianjin Customs of the People's Republic of China, Xinjiang University.

1 Scope

This standard specifies the atomic absorption spectrometry method for the determination of gold content in gold-loaded resin materials.

This standard applies to the determination of gold content in gold-loaded resin materials.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 602 Preparation of standard solutions for impurity determination of chemical reagents GB/T 6682 Analytical laboratory water specifications and test methods

3 Method summary

After the sample is roasted to remove sulfur and organic matter, it is dissolved with hydrochloric acid and nitric acid, and the gold, the adsorbed gold chloride complex or the After the gold bromine complex is dissolved and liberated with thiourea, its gold content is measured with a flame atomic absorption spectrometer.

4 Reagents and materials

Unless otherwise specified, only reagents confirmed to be analytically pure are used in the analysis, and the experimental water meets the first-grade water specified in GB/T 6682.

4.1 Hydrochloric acid (rho=1.19 g/mL).

4.2 Nitric acid (rho=1.42 g/mL).

4.3 Thiourea.

4.4 Bromine.

4.5 Dilute hydrochloric acid (1.9).

4.6 Gold standard stock solution (1 000 µg/mL). Prepare according to GB/T 602 method or directly use certified national standard materials.

4.7 Gold standard working solution (100 µg/mL). Pipette 10 mL of gold standard stock solution (4.6) into a 100 mL volumetric flask, and use dilute hydrochloric acid (4.5) Dilute to the mark and mix well.

4.8 Aqua regia. mix 3 parts of hydrochloric acid (4.1) and 1 part of nitric acid (4.2), and prepare when used.

4.9 Aqua regia (1.1). Mix 1 part of aqua regia (4.8) and 1 part of water, and prepare when used.

4.10 Saturated bromine water. Dissolve a certain amount of bromine (4.4) in water, partially dissolve bromine (4.4), and take the supernatant to obtain saturated bromine (4.4).

And bromine water.

4.11 Thiourea solution (10 g/L). Weigh 1 g of thiourea (4.3) and dissolve it in 100 mL of water.

4.12 Sodium hydroxide solution (10 g/L). Weigh 10 g of sodium hydroxide and dissolve it in 1 L of water.

4.13 Plastic foam. polyurethane type or polyether type, cut into blocks of 3 cm×3 cm×1 cm, rinse with water before use, Boil in sodium solution (4.12) for 15 minutes, wash with water until neutral, dry, and set aside.

5 Apparatus and equipment

5.1 Atomic absorption spectrophotometer. equipped with a gold element hollow cathode lamp.

5.2 Analytical balance. Sensitivity is 0.0001 g.

5.3 High-temperature furnace. The temperature can be controlled between 500 °C and 1 000 °C.

5.4 Electric heating plate. can be heated to.200 °C.

5.5 Oscillator.

5.6 Porcelain crucible. 30 mL.

5.7 Colorimetric tube. 25 mL.

5.8 Volumetric flask. 50 mL.

6 Sample

The particle size of the gold-loaded resin material analysis sample should be less than 0.096 mm, and it should be baked at 105 °C ± 5 °C for 2 h, and then cooled to room temperature in a desiccator for later use.

7 Analysis steps

7.1 Sample processing

Weigh 10.0 g (accurate to 0.0001 g) of the sample and place it in a 30 mL porcelain crucible (5.6), and place it in a high-temperature furnace (5.3) at 650 °C Burn for 2 h, after cooling, transfer to a 250 mL Erlenmeyer flask, add 25 mL of aqua regia (4.9), heat and boil on the electric hot plate (5.4) for 1 h, Dilute with water to 70 mL, add 3.0 mL saturated bromine water (4.10), and shake quickly. After cooling to room temperature, put in 0.2 g~0.4 g plastic bubble Foam (4.13), cover the stopper, shake on the shaker (5.5) for 30 minutes, take out the foam with a glass rod, and wash with water to remove foam the residue and acid on the plastic squeeze out the water. Put the foam plastic into a 25 mL colorimetric tube pre-filled with 15.0 mL thiourea solution (4.11) in (5.7), put it in a boiling water bath to release for 30 minutes, and take out the colorimetric tube (5.7). Move the foam plastic up to the upper part of the colorimetric tube (5.7) and squeeze it dry Then take it out, cool the solution to room temperature, dry filter, and take the clear solution for measurement.

7.2 Blank test

Do a blank test with the sample.

7.3 Production of working curve

Pipette 0 mL, 0.20 mL, 0.24 mL, 0.48 mL, 0.68 mL, 0.90 mL gold standard working solution (4.7) into 6 250 mL in the Erlenmeyer flask, follow the steps in (7.1). The concentrations of gold are 1.33 µg/mL, 1.60 µg/mL, 3.20 µg/mL, 4.53 µg/mL, 6.00 µg/mL, with the concentration of gold (µg/mL) as the abscissa and the absorbance value as the ordinate, draw a standard working curve.

7.4 Determination

Adjust the working conditions of the instrument to make the instrument to the best condition, and perform the standard working solution, sample blank solution and sample solution in sequence.

Determination. If the content of the gold element in the sample solution exceeds the content range of the standard curve, the sample solution can be diluted and re-measured. Instrument work See Appendix A for conditions.

8 Result calculation

Calculate the content of gold in the sample according to formula (1).

omegai-the content of each gold element, in micrograms per gram (µg/g);

cx-the concentration of gold in the sample solution obtained from the working curve, in micrograms per milliliter (µg/mL);

c0-the concentration of gold in the blank solution obtained from the working curve, in micrograms per milliliter (µg/mL);

V-the volume of the sample solution, the unit is milliliters (mL);

m-the mass of the sample, the unit is grams (g);

k - Dilution factor.

Note. The result is the arithmetic average of two parallel determination results, expressed to two decimal places.

9 Precision

Under repeatability conditions, the absolute difference between the two independent determination results is not more than 20% of the arithmetic mean. Under repeatability conditions, two the absolute value of a laboratory measurement result is not more than 30% of the arithmetic mean.

Appendix A

(Informative appendix)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 5248-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 5248-2020

$90.00