Valid

SN/T 4546-2017Commercialization kit detection method Staphylococcus aureus method (English PDF)

商品化试剂盒检测方法 金黄色葡萄球菌 方法一

Preview PDF

This is a limited preview

Buy now to download the full PDF (1 pages)

Need quotation for your management?

Get a formal quotation for SN/T 4546-2017 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Recommended

Issue date

May 12, 2017

Implementation date

December 1, 2017

Scope

SN/T 4546-2017 is the English-translated version of 商品化试剂盒检测方法 金黄色葡萄球菌 方法一.

SN/T 4546-2017 — This standard specifies the PetrafilmTM Staphylococcus aureus CountPlate in food. Detection method. This standard applies to the count of Staphylococcus aureus in exported foods and raw materials.

Found what you need?

Document preview — SN/T 4546-2017

National Standard of the People's Republic of China

Classification
G 66
Replacing
SN/T 1895-2007

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Biosecurity measures
  • 4 Technical Overview
  • 5 Equipment and materials

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard replaces the SN/T 1895-2007 "RapidumTMTM Test Method for Rapid Counting of Staphylococcus aureus in Foods". versus Compared with SN/T 1895-2007, the main technical changes except editorial changes are as follows.

--- Modified the standard Chinese and English names;

--- Modified Appendix A.

--- Increased the calculation formula;

--- Added Appendix B;

--- Removed the second method PetrifilmTM test piece MPN method.

This standard is proposed and managed by the National Certification and Accreditation Administration.

This standard was drafted. Liaoning Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, China Academy of Inspection and Quarantine, Dalian Qiyuan Branch Technology Development Co., Ltd.

1 Scope

This standard specifies the PetrafilmTM Staphylococcus aureus CountPlate in food.

Detection method.

This standard applies to the count of Staphylococcus aureus in exported foods and raw materials.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article.

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB 19489 General requirements for laboratory biosafety

3 Biosecurity measures

In order to protect the safety of laboratory personnel and prevent contamination, they should be tested by qualified personnel. All cultures and waste the treatment shall be carried out in accordance with the relevant provisions of GB 19489.

4 Technical Overview

The S. aureus test piece method is performed using a pre-prepared medium system containing indicator and cold water soluble gel.

Method of biological culture.

Staphylococcus aureus test strip STX (StaphExpressCountPlate) contains Baird- with improved color rendering function Parker medium has a strong selectivity for Staphylococcus aureus. The purple-red colony on the test piece was Staphylococcus aureus. If in the case of a color other than fuchsia, it is necessary to use a confirmation reaction sheet containing a developer and deoxyribonucleic acid (DNA). Golden Staphylococcus aureus DNase produces a pink halo with the developer in the reaction sheet.

5 Equipment and materials

In addition to routine sterilization and culture equipment in microbiology laboratories, other equipment and materials are as follows.

5.1 Constant temperature incubator. 36 °C ± 1 °C.

5.2 Electronic balance. The sensitivity is 0.1g.

5.3 Homogenizer (rotary or tap) or equivalent equipment.

5.4 pH meter or precision pH test paper. precision 0.1.

5.5 Pipette. 1 mL (with 0.01 mL scale), 10 mL (with 0.1 mL scale) or pipette and tip.

5.6 Test plate pressure plate.

5.7 Magnifier or/and colony counter.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 1 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 4546-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
1 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 4546-2017

$185.00