SN/T 3720.1-2013Rules for the inspection of import pump. Part 1: Energy efficiency of the water chillers(and beat pumps) (English PDF)
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for SN/T 3720.1-2013 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
November 6, 2013
Implementation date
June 1, 2014
Scope
SN/T 3720.1-2013 (Rules for the inspection of import pump. Part 1: Energy efficiency of the water chillers(and beat pumps)) is available as an English-translated PDF.
SN/T 3720.1-2013 - SN/T 3720 provisions of this part of the import of cold water (heat pump) energy efficiency requirements, test results and determination. This section applies to imports of motor-driven compressor of the vapor compression cycle with cold water (heat pump) unit (hereinafter referred to as "units") products.
This section does not apply to other industrial purposes designed steam compression cycle in cold water (heat pump).
Found what you need?
Document preview — SN/T 3720.1-2013
National Standard of the People's Republic of China
- ICS
- 23.080
- Classification
- J71
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
This section SN/T 3720 "inspection of the pump inlet," Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
1 Scope
SN/T 3720 provisions of this part of the import of cold water (heat pump) energy efficiency requirements, test results and determination.
This section applies to imports of motor-driven compressor of the vapor compression cycle with cold water (heat pump) unit (hereinafter referred to as "units") products.
This section does not apply to other industrial purposes designed steam compression cycle in cold water (heat pump).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 10870 displacement and centrifugal water (heat pump) performance test methods GB/T 18430 (all parts) vapor compression cycle with cold water (heat pump) GB 19577-2004 chiller energy efficiency of limited value and energy efficiency rating GB 50189-2005 public building energy efficiency design standards Chiller energy efficiency labeling rules (National Development and Reform Commission, the State Administration of Quality Supervision, CNCA Announcement No. 8, 2008)
3 Terms and Definitions
The following terms and definitions apply to this document.
Cold water (heat pump) energy efficiency limit theminimumalowablevaluesofenergyefficiencyforwaterchilers Refrigeration unit at rated conditions and specified conditions, the coefficient of performance or nominal operating conditions Integrated Part Load factor minimum allowed value, Jane He said energy efficiency limit values.
Evaluating values of energy cold water (heat pump) theevaluatingvaluesofenergyconservationforwaterchilers Refrigeration unit at rated conditions and specified conditions, the coefficient of performance energy-efficient unit should reach the minimum.
Energy efficiency rating energyefficiencygrades A hierarchical method referred to as the energy efficiency rating, the level of energy efficiency of products represents the difference, according to the size of the coefficient of performance determined, in turn divided into 1,2,3,4,5 five levels, level 1 is the highest energy efficiency.
Cold water (heat pump) unit rated energy efficiency grade ratedenergyefficiencygradesforwaterchilers Product by the manufacturer on the predetermined unit of energy efficiency rating.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 10870The methods of performance test for water chilling (heat pump) packages using the vaper compression cycle
- GB/T 18430.1Water chilling (heat pump) packages using the vapor compression cycle - Part 1: Water chilling (heat pump) packages for industrial & commercial and similar applications
- GB/T 18430.2Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications
- GB 19577-2004Minimum allowable values of energy efficiency and energy efficiency grades for heat pumps and water chillers
- GB 50189-2005Design standard for energy efficiency of public buildings
chiller energy efficiency labeling rules (National Development and Reform Commission, the AQSIQ, CNCA 2008 8 announcement)
How to Download SN/T 3720.1-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10870-2014 — The methods of performance test for water chilling (heat pump) packages using the vaper compression cycle
GB/T 18430.1-2024 — Water chilling (heat pump) packages using the vapor compression cycle - Part 1: Water chilling (heat pump) packages for industrial & commercial and similar applications
GB/T 18430.2-2025 — Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications
Secure payment via Stripe
Payments accepted
SN/T 3720.1-2013