Valid

SN/T 3596-2013Test method for total fluorine in coal by the oxygen bomb combustion-ion selective electrode method (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for SN/T 3596-2013 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

SN/T 3596-2013 (Test method for total fluorine in coal by the oxygen bomb combustion-ion selective electrode method) is available as an English-translated PDF.

SN/T 3596-2013 — This standard specifies the Oxygen Bomb Combustion - Coal method for the determination of total fluorine content of the ion selective electrode method.

This standard is applicable to the determination of total fluorine in coal at 25% or less in ash content.

Found what you need?

Document preview — SN/T 3596-2013

National Standard of the People's Republic of China

ICS
73.040
Classification
D 21

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 Instrument

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

The standard reference American Society for Testing Materials Standard ASTMD3761:1996 (2002) "Oxygen Bomb Combustion/Ion Selective Electrode Method Standard Method for Total Fluorine in Coal "(in English).

This standard ASTMD3761:1996 (2002) The main differences are as follows.

--- You will be prompted on security issues (ASTMD3761:1996 in 1.4) on the text of the first.

--- "This test method" be replaced by "of this standard."

--- According to GB/T 1.1-2009 "Standardization Guide Part 1. Standard structure and writing" requirement, the ASTM D3761:1996 (2002) of Chapter 2 to normative references.

--- Delete this standard requires independent technical content, ASTMD3761:1996 (2002) the chapter number 1.3,1.5,4,14.

--- The ASTMD3761. in 71996 (2002) for details about the use of the oxygen bomb warning of the risk in Appendix A.

--- Part precision textual representation according to GB/T 20001.4-2001 standard requirements were modified.

This standard is proposed and managed by the National Certification and Accreditation Administration Committee.

This standard was drafted. People's Republic of China Guangdong CIQ.

Drafters of this standard. Tian Joan Liu Yifeng, Xu Jinlong, Zhang Xi, Lin, Zheng Shujian, Cui Weiguo.

Determination of the import and export of coal in total fluorine content Oxygen Bomb Combustion/Ion Selective Electrode Method Warning. This standard does not mention the use of the same standard for all security issues. Users are responsible before the application of this standard, to take appropriate Safety and health practices and to ensure compliance with relevant laws and regulations.

1 Scope

This standard specifies the Oxygen Bomb Combustion - Coal method for the determination of total fluorine content of the ion selective electrode method.

This standard is applicable to the determination of total fluorine in coal at 25% or less in ash content.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB 474 coal sample preparation GB/T 483 coal analysis test methods - General provisions GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat of the basic methods of reproduction Laboratory use specifications and test methods GB/T 6682 Analysis ASTME144 Safety and Operating Instructions oxygen combustion bomb

3 Method summary

Weigh a certain quality of coal in an oxygen bomb combustion decomposition, absorb fluorine-containing gas with dilute lye, rinsed with water and oxygen bomb, lotions and absorbing liquid Combined, then add citrate buffer, a fluoride ion selective electrode determination of total fluorine content.

4 Instrument

4.1 Oxygen Bomb. made from combustion or combustion products influence the material should be suitable for use in the washing liquid collected quantitative surface burning Combustion Products. Test gas leak can not appear. Oxygen bomb must be able to 20MPa hydrostatic pressure test at room temperature, should be part of any Force must not exceed the elastic limit. The risk of using oxygen bomb prompted see Appendix A.

4.2 Sink. a bomb capable of receiving oxygen and sufficient water containers, water to take the heat release during combustion. The sink sit at design time Taking into account the presence of the oxygen bomb around a constant rate of flow.

4.3 Combustion Crucible. The sample should be in an open platinum, a base metal or alloy produced quartz crucible combustion. The use of base metal alloys After the crucible by making a certain number of pre-combustion stability during the test should not be noticeable quality changes.

4.4 ignition wire. 100mm, nickel chromium alloy or platinum.

4.5 ignition circuit. a 6V ~ 16V AC or DC circuits for ignition, the circuit should be equipped with LEDs to indicate power or ammeter flow. Battery or AC step-down transformer to the lighting circuit.

4.6 Analysis of balance. a sense of the amount of 0.1mg.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 3596-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 3596-2013

$184.00