QC/T 942-2013Test method for hexavalent chromium in automotive materials (English PDF)
汽车材料中六价铬的检测方法
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for QC/T 942-2013 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
October 17, 2013
Implementation date
March 1, 2014
Scope
QC/T 942-2013 is the English-translated version of 汽车材料中六价铬的检测方法.
QC/T 942-2013 is the Chinese standard "Test method for hexavalent chromium in automotive materials". Its scope clause reads: This standard specifies the methods for determining the hexavalent chromium content in automobile parts and materials.
Among them, "X-ray fluorescence spectrometry" is applicable for screening and fast determining the hexavalent chromium content in automobile materials using X-ray fluorescence spectrometry.
"Qualitative test on hexavalent chromium in anti-corrosive metal coating" is applicable for determining the existence of hexavalent chromium in anti-corrosive coating of automobile using spot method and boiling extraction method.
"Determination of hexavalent chromium content in anti-corrosive metal coating" is applicable for determining the hexavalent chromium content in anti-corrosive coating using boiling extraction method and colorimetry.
The two methods are applicable to coating without additional covering layers (such as oil film, water-based or solvent-based polymer film or waxy film).
"Determination of hexavalent chromium content in polymer material and electronic material" is applicable for determining the hexavalent chromium content in polymer materials and electronic materials using alkali liquor extraction method and colorimetry, but not applicable to PE and EVAC materials.
The hexavalent chromium content in other automobile materials, such as glass, ceramics, fabric, and paint coating, is determined by reference to this method. "Determination of hexavalent chromium content in leather" is applicable for determining the hexavalent chromium content in leather using phosphate solution extraction method and colorimetry. Its clauses include x-ray fluorescence spectrometry.
Found what you need?
Document preview — QC/T 942-2013
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword i
- Introduction ii
- 1 Scope
- 2 Normative References
- 3 X-Ray Fluorescence Spectrometry
- 4 Qualitative Test on Hexavalent Chromium in Anti-corrosive Metal Coating
- 5 Determination of Hexavalent Chromium Content in Anti-corrosive Metal Coating
- 6 Determination of Hexavalent Chromium Content in Polymer Material and Electronic Material
- 7 Determination of Hexavalent Chromium Content in Leather
- 8 Test Report
- Annex A (Informative) Calculation Method of Fastener Coating Surface Area
- Annex C (Normative) Determination of Volatile Content in Leather
- Annex D (Normative) Determination of Recovery Rate by Determination of Hexavalent Chromium Content in Leather
1 Scope
This standard specifies the methods for determining the hexavalent chromium content in automobile parts and materials. Among them,
"X-ray fluorescence spectrometry" is applicable for screening and fast determining the hexavalent chromium content in automobile materials using X-ray fluorescence spectrometry.
"Qualitative test on hexavalent chromium in anti-corrosive metal coating" is applicable for determining the existence of hexavalent chromium in anti-corrosive coating of automobile using spot method and boiling extraction method. "Determination of hexavalent chromium content in anti-corrosive metal coating" is applicable for determining the hexavalent chromium content in anti-corrosive coating using boiling extraction method and colorimetry. The two methods are applicable to coating without additional covering layers (such as oil film, water-based or solvent-based polymer film or waxy film).
"Determination of hexavalent chromium content in polymer material and electronic material" is applicable for determining the hexavalent chromium content in polymer materials and electronic materials using alkali liquor extraction method and colorimetry, but not applicable to PE and EVAC materials. The hexavalent chromium content in other automobile materials, such as glass, ceramics, fabric, and paint coating, is determined by reference to this method.
"Determination of hexavalent chromium content in leather" is applicable for determining the hexavalent chromium content in leather using phosphate solution extraction method and colorimetry.
2 Normative References
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 1839 Steel Product Zinc Coating Mass Testing Method (GB/T 1839-2008, ISO 1460:1992, MOD)
GB/T 8170 Rules of Rounding Off for Numerical Values & Expression and Judgment of Limiting Values
GB/T 20017 Metallic and Other Non-organic Coatings - Determination of Mass per Unit Area - Review of Gravimetric and Chemical Analysis Methods (GB/T 20017-2005, ISO 10111:2000, IDT)
GB/T 30512-2014 Requirements for Prohibited Substances on Automobiles
GB/Z 21277-2007 Rapid Screening of Lead, Mercury, Chromium, Cadmium and Bromine of Regulated Substances in Electrical and Electronic Equipment - X-ray Fluorescence Spectrometry
QB/T 2262-1996 Terms for Leather Industry
QB/T 2706 Leather - Chemical, Physical and Mechanical and Fastness Tests - Sampling Location (QB/T 2706-2005, ISO 2418:2002, MOD)
IEC 62321:2008 Ed.1.0 Electrotechnical Products - Determination of Levels of Six Regulated Substances (Lead, Mercury, Cadmium, Hexavalent Chromium, Polybrominated Biphenyls, Polybrominated Diphenyl Ethers)
ISO 3613:2000 Chromate Conversion Coatings on Zinc, Cadmium, Aluminium - Zinc Alloys and Zinc-Aluminium Alloys - Test Methods
EN ISO 17075:2007 Leather - Chemical Tests - Determination of Chromium(6) Content
3 X-Ray Fluorescence Spectrometry
3.1 Principle
Put the prepared sample into the sample room of X-ray fluorescence spectrometry; carry out X-ray fluorescence spectrometric analysis on the chromium content in the sample according to the analysis mode selected, and judge whether the chromium content conforms to the screening limit, and whether accurate determination is necessary.
Note: the result obtained by X-ray fluorescence spectrometric analysis is the total chromium in the sample, rather than the hexavalent chromium.
3.2 Reagents and materials
3.2.1 Boric acid
guaranteed reagent, baking 1h at 105°C and storing in the dryer.
3.2.2 Anhydrous lithium tetraborate
guaranteed reagent, baking 4h at 700°C and storing in the dryer.
3.2.3 Liquid nitrogen
industrial grade.
3.2.4
Standard material containing chromium.
3.3 Apparatus
3.3.1
X-ray fluorescence spectrometer.
3.3.2
Cutter.
3.3.3
Liquid nitrogen low-temperature pulverizer.
3.3.4 Grinder
grinding apparatus with wolfram carbide (WC).
3.3.5 Tablet press
the working pressure >=20MPa.
3.3.6 Fusion machine
working temperature >=1150°C.
3.4 Sample preparation
3.4.1
Sample preparation principal.
3.4.1.1
The sample subject to analysis must cover the measuring window of spectrometer.
3.4.1.2
The sample's exposure side shall be able to represent the entire sample.
3.4.1.3
Attention shall be paid to prevent pollution during sample preparation.
3.4.2
Sample preparation method.
3.4.2.1 Solid samples. Direct analysis may be conducted on the homogeneous samples with the smooth surface and size suitable for the X-ray fluorescence spectrometer. Small samples may be gathered together for analysis. The thin samples may be stacked to reach the sufficient thickness (at least 5mm). Special attention shall be paid to the consistency of sample thickness and homogeneity of composition. During analysis, spread the samples in a flat and smooth way; lining material may be added to serve as the support; lining material with low background is recommended.
Irregularly-shaped or oversized samples, such as blocks, plates, shall be processed to the proper size with cutter, grinder, etc. Small samples (such as plastic particles) shall be pressed by tablet press to be analytical samples after undergoing liquid nitrogen refrigeration and mechanical grinding.
The fragile samples, such as glass and ceramics, shall be pulverized into small blocks, and then grinded to powder less than 200-mesh (0.074mm). Mix the powder uniformly. Put the boric acid (3.2.1) at the bottom to prepare the sample with tablet press, and the bottom thickness shall not be less than 1mm; or use anhydrous lithium tetraborate (3.2.2) to prepare analytical sample of glass melting piece.
As for the heterogeneous sample composed of heterogeneous materials and with further mechanical separation not necessary or difficult, cut to break the sample and subject it to liquid nitrogen refrigeration. Use the grinder to grind the broken sample into powder with particle size not more than 1mm. Mix the powder uniformly. Put the boric acid (3.2.1) at the bottom to prepare the sample with tablet press, and the thickness shall not be less than 1mm; or use anhydrous lithium tetraborate (3.2.2) to prepare analytical sample of glass melting piece.
3.4.2.2
Liquid sample. Transfer a certain volume of liquid sample into the liquid-dedicated sample cup (the sample thickness is at least 15mm); the cup is supported by 6mm-thick polyester film at bottom, and covered by perforated cap.
3.5 Analytical procedures
3.5.1
Preparation of apparatus.
Activate the apparatus according to the operation procedures, and preheat the apparatus until it gets stable.
3.5.2
Analytical line.
Kalpha analytical line is recommended for analyzing chromium with X-ray fluorescence spectrometry.
3.5.3 Plotting of working curve
Select the standard material which basically matches to the to-be-tested sample; determine the fluorescence intensity of chromium in the standard material under the measuring conditions of X-ray fluorescence spectrometer; plot the working curve based on the standard value given for the standard material and the intensity measured by the spectrometer.
3.5.4
Calibration.
Before testing the sample every time, calibrate the working curve using the chromium-containing standard material (3.2.4).
3.5.5
Sample testing.
Put the prepared sample into the sample room, and analyze the sample according to the selected mode. Each sample shall be analyzed twice at least.
3.6 Result analysis
3.6.1
Result calculation.
Calculate the chromium content in the sample using the obtained spectral line intensity of chromium, according to the selected analysis mode.
3.6.2
Screening of hexavalent chromium.
Set the screening limits (Table 1) of chromium in automobile materials according to Requirements for Prohibited Substances on Automobiles which specifies that the limit of hexavalent chromium (calculated in total chromium) is mass fraction 0.1% (1000mg/kg); screen the chromium in automobile material according to the screening limits. Two results are obtained:
Pass (P) - - it is conforming if all the analysis results are below the lower limit;
Unknown (X) - - it is unknown if the analysis results exceed the lower limit, and the hexavalent chromium shall be determined.
Table 1 Screening Limits of Chromium Content in Automobile Materials mg/kg
Sample category Polymer Other materials
Screening limits P<=700-3S<X P<=500-3S<X
Notes: 1 S is the standard deviation of analysis result.
2 The result is conforming if the determined value of chromium falls in P domain, and unknown if falls in X domain.
3.6.3
Report of test result.
Report the arithmetic average of test results, in mass fraction (%) or mg/kg.
Based on the screening limit, determine whether the chromium content in the sample is conforming and whether further quantitative test is necessary.
4 Qualitative Test on Hexavalent Chromium in Anti-corrosive Metal Coating
4.1 Principle
The hexavalent chromium in the anti-counterfeit metal coating reacts with diphenylcarbazide to generate purple red complex, which indicates the existence of hexavalent chromium in the coating.
4.2 Reagents and materials
Unless otherwise specified, only recognized analytical reagent and distilled water, deionized water or water with equivalent purity are used in analysis.
4.2.1
Diphenylcarbazide.
4.2.2 Potassium dichromate
standard reagent.
4.2.3
Acetone.
4.2.4
Ethanol (95%).
4.2.5
Orthophosphoric acid solution (13+7).
4.2.6 Stock solution of hexavalent chromium
weigh 0.1414g of potassium dichromate (4.2.2) dried to constant mass, dissolve it into water, transfer the solution into 100mL volumetric flask and dilute to the scale. The hexavalent chromium content is 500µg/mL in this solution. Cap the container tightly to store for 1 year, or national standard solution is adopted.
4.2.7 Standard solution of hexavalent chromium
transfer 0.50mL stock solution of hexavalent chromium (4.2.6) into 250mL volumetric flask and dilute to the scale. The hexavalent chromium content is 1µg/mL in this standard solution. Cap the container tightly, and this solution shall be used within 24h after preparation. This standard solution of hexavalent chromium, i.e. solution with 1µg/mL hexavalent chromium content, may also be prepared with national standard solution.
4.2.8 Developing solution A
weigh 0.4g of diphenylcarbazide (4.2.1) and dissolve into the mixture of 20mL of acetone (4.2.3) and 20mL of ethanol (4.2.4); after dissolution, add 20mL of orthophosphoric acid solution (4.2.5) and 20mL of water. This solution shall be used within 8h after preparation.
4.2.9 Developing solution B
weigh 0.5g of diphenylcarbazide (4.2.1) and dissolve into 50mL of acetone (4.2.3); dilute the mixture with 50mL of water by stirring slowly (rapid mixing will generate diphenylcarbazide precipitate). This solution shall be refrigerated in a brown bottle and shall not be used if its color changes.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 47246-2026Technical specification for the electronic functions of child restraint systems for power-driven vehicles
- GB/T 41006-2021General technical requirements for polyurethane synthetic leather used for vehicle
- QC/T 568-2019Specifications and bench test methods for automotive manual transmission assemblies
Similar standards
How to Download QC/T 942-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
QC/T 1005-2026 — Performance requirements and bench test methods for hydraulic solenoid valve assembly of electronic stability control system and antilock brake system of automoive
QC/T 1022-2026 — Technical specifications and test methods of reduction gearbox for battery electric vehicles
QC/T 1041-2026 — Control system of fuel evaporative pollutants from Motorcycles with petrol engine
QC/T 942-2013
$325.00