This is a limited preview
Buy now to download the full PDF (28 pages)
Need quotation for your management?
Get a formal quotation for QC/T 471-2025 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of the People’s Republic of China
Level / Type
National · Recommended
Issue date
May 9, 2025
Implementation date
November 1, 2025
Scope
QC/T 471-2025 (Automotive diesel engine) is available as an English-translated PDF.
QC/T 471-2025 is the Chinese standard "Automotive diesel engine". Its scope clause reads: This Document specifies the method for testing the cleanliness of automobile transmission assembly.
This Document applies to the cleanliness testing of Types M and N automobile transmission assembly and electric drive assembly (including lubricating oils and components).
Its clauses include terms and definitions. It was issued by the Ministry of Industry and Information Technology of the People’s Republic of China on 2025-05-09 and took effect on 2025-11-01.
Found what you need?
Document preview — QC/T 471-2025
National Standard of the People's Republic of China
- ICS
- 43.040
Issued by: Ministry of Industry and Information Technology of the People’s Republic of China
Contents
- Foreword...3
- 1 Scope...6
- 2 Normative References...6
- 3 Terms and Definitions...6
- 4.Testing Methods...9
- 4.1 Test requirements...9
- 4.2 Preparation for test...11
- 4.3 Impurity extraction...15
- 4.4 Impurity analysis...18
- 4.5 Report on results...25
- Appendix A (Normative) Sampling Rules...26
- Bibliography...28
1 Scope
This Document specifies the method for testing the cleanliness of automobile transmission assembly.
This Document applies to the cleanliness testing of Types M and N automobile transmission assembly and electric drive assembly (including lubricating oils and components).
2 Normative References
The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document.
GB/T 14039 Hydraulic fluid power – Fluids - Method for coding the level of contamination by solid particles
GB/T 25915.1-2021 Cleanrooms and associated controlled environments - Part 1.
Classification of air cleanliness by particle concentration
GB/T 41481-2022 Road vehicles - Cleanliness of components and systems
3 Terms and Definitions
For the purposes of this Document, the following terms and definitions apply.
3.1 Cleanliness of assembly
The cleanliness of assembly is expressed by the mass or quantity, geometric size, and type of impurity particles.
NOTE. The cleanliness of assembly is divided into cleanliness of disassembly and cleanliness of non- disassembly.
3.2 Impurity
Pollutants that enter from the outside, remain on the product itself, or are generated by the system during the product's manufacturing, storage, transportation, use, and maintenance.
3.3 Filter membrane
The cleanliness test uses a polymer film sheet with a knitted or mesh structure and special separation capabilities to retain the particles of interest through separation.
3.4 Cleaner
The liquid medium that is used to clean the sample.
3.5 Blank experiment
A set of experiments to determine the cleanliness of the system using methods for detecting sample cleanliness in the absence of a sample.
3.6 Mass constant
The process of repeatedly drying, cooling, and weighing a substance until its mass remains constant.
3.7 Blank value
The value that is obtained from blank experiment.
3.8 Attenuation test
A set of tests that is used to determine cleaning parameters such as sample cleaning pressure, flow rate, and flow velocity, etc.
3.9 Lubricating oil
Liquid lubricant that is used between the relatively moving surfaces of a friction pair.
3.10 Particle
Tiny structures formed from solid organic or inorganic matter, such as metals, plastics, ceramics, minerals, rubber, and fibers, etc.
3.11 Particle size
It mainly includes particle length, particle width, and inscribed circle diameter of the particle.
NOTE. Unless otherwise specified, the longest size shall be used.
3.12 Particle length
The maximum vertical distance between two parallel lines at both ends of the particle is
4.Testing Methods
4.1 Test requirements
4.1.1 Samples and lubricating oil
4.1.1.1 Cleanliness test of Types M and N automotive transmission assemblies and electric
drive assemblies (hereinafter referred to as "assemblies") alters the cleanliness characteristics of the sample; therefore, cleanliness test shall not be repeated on the same sample.
4.1.1.2 For lubricating oil cleanliness test (such as contamination level and elemental analysis), samples can be retained for retest if the lubricating oil is homogeneous.
4.1.2 Cleaner
The cleaner shall meet the following requirements.
a) It shall be able to quickly remove impurities from the sample without altering the characteristics of the impurity particles;
b) It shall be non-corrosive to the sample, harmless to the human body, and not chemically a) The testing room shall have independent working areas for impurity extraction, drying, and analysis;
b) The testing room shall have dust prevention measures, and the indoor cleanliness level shall at least meet the ISO Class 9 requirements of GB/T 25915.1-2021;
c) The testing room shall be well-ventilated, with a temperature of 15°C~30°C and relative humidity <=70%;
d) The testing room shall have fire prevention and anti-static measures.
4.1.6 Samples
Samples shall meet the following requirements.
a) Samples shall be sealed in packaging during transportation and storage to avoid collisions and contamination from external pollutants;
b) Non-testing areas shall be cleaned before testing.
4.1.7 Blank value
The blank value shall meet the following requirements.
a) The mass or number of the particles shall be less than 1/10 of the sample cleanliness limit;
b) The largest particle shall be less than half the maximum permissible particle size of the sample, determined according to the lower limit of the particle's range; see Table 5 for range division;
c) The blank value shall not be deducted from the test results.
4.1.8 Personnel
Personnel shall meet the following requirements.
a) Testing personnel shall wear anti-static and dustproof work clothes and caps;
b) Testing personnel shall be professionally trained, familiar with the testing process, proficient in operating the testing equipment, able to diagnose equipment malfunctions, and perform routine maintenance.
4.2 Preparation for test
4.2.1 Impurity extraction device
The impurity extraction device may include.
a) Manual filtration devices, including. cleaning chamber with exhaust system, vacuum pump, pressure tank, spray gun, funnel, filter membrane support frame, suction flask, etc.;
b) Automatic filtration devices, including. cleaning chamber, spray gun, automatic membrane forming system, automatic circulating filtration system, etc.;
c) Glassware, including. desiccator, weighing bottle, conical flask, measuring cup, measuring cylinder, etc.;
d) Other apparatuses, including. sampler, flat-tipped toothless stainless steel tweezers, weighing pan, oil-resistant rubber gloves, etc.
4.2.2 Instruments
The following instruments may be used for test.
a) Drying oven;
b) Analytical balance. graduation value <= 0.1 mg;
c) Optical microscope. capable of automatically and clearly identifying impurity particles >=
5 µm; and statistically analyzing their type, size, and quantity, classifying them according to size grade; and determine the cleanliness grade according to the cleanliness grade code provided in GB/T 41481-2022;
d) Automatic particle counter. capable of counting particles >= 4 µm, and determine the cleanliness grade according to the cleanliness grade code provided in GB/T 14039;
e) Scanning electron microscope-energy dispersive spectroscopy;
f) Emission spectrometer. including oil spectrometer, full-spectrum direct-reading plasma emission spectrometer, energy dispersive (or wavelength dispersive) X-ray fluorescence spectrometer, etc.;
g) Fourier transform infrared spectrometer/Raman spectrometer;
h) Fourier transform micro-infrared spectrometer.
4.2.3 Sampling
Sampling may be performed according to Appendix A.
4.2.4 Preparation of filter membrane
4.2.4.1 Cleaning
Before use, the filter membrane shall be cleaned according to the following steps.
a) Immerse the filter membrane in a clean cleaning solution;
b) Place the cleaned filter membrane in a weighing bottle.
NOTE. The orientation of polyester fiber membranes shall be consistent with the orientation indicated on the manufacturer's packaging.
4.2.4.2 Drying
Slightly open the weighing bottle cap and place it in a drying oven to dry. The drying temperature and time shall be determined experimentally based on the type of cleaner and the filter membrane material.
4.2.4.3 Cooling
Tightly close the weighing bottle cap and place it in a desiccator to cool to room temperature.
The cooling time shall be consistent.
4.2.4.4 Weighing
Weigh the filter membrane on a balance, accurate to 0.1 mg; and record the weighing value.
4.2.4.5 Mass constant
Repeat steps 4.2.4.2 to 4.2.4.4 until the difference between two consecutive masses is <=0.4 mg.
NOTE. When performing only the light microscopy method, follow step 4.2.4.1.
4.2.5 Blank test
4.2.5.1 The light microscopy method steps are as follows.
a) Use the specified volume of cleaner to clean the sampling tool, support, and inner wall of the cleaning chamber; filter; and remove the filter membrane;
b) Flatten and place the filter membrane, after the cleaner has evaporated, under the microscope;
c) After the microscope scan is complete, check the size and quantity of metal particles, non- metal particles, and fibers in sequence.
4.2.5.2 The steps of the mass method are as follows.
a) Use the specified volume of cleaner to clean the sampling tools, support, and inner walls of the cleaning chamber, etc.; filter with a filter membrane with constant mass; and take out the filter membrane and place it in a weighing bottle;
b) Dry, cool, and weigh according to 4.2.4.2~4.2.4.4;
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 28 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 14039Hydraulic fluid power -- Fluids -- Method for coding the level of contamination by solid particles
- GB/T 25915.1-2021Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration
- GB/T 41481-2022Road vehicles - Cleanliness of components and systems
How to Download QC/T 471-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14039-2002 — Hydraulic fluid power -- Fluids -- Method for coding the level of contamination by solid particles
GB/T 25915.1-2021 — Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration
GB/T 41481-2022 — Road vehicles - Cleanliness of components and systems
Secure payment via Stripe
Payments accepted
QC/T 471-2025
$400.00