Valid

QC/T 417.2-2001Road vehicles - Connectors for on-board electrical wiring harnesses - Part 2: Test methods and general performance requirements (motorcycles) (English PDF)

车用电线束插接器 第2部分 试验方法和一般性能要求(摩托车部分)

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for QC/T 417.2-2001 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

August 21, 2001

Implementation date

December 1, 2001

Scope

QC/T 417.2-2001 is the English-translated version of 车用电线束插接器 第2部分 试验方法和一般性能要求(摩托车部分).

QC/T 417.2-2001 is Part 2 of the Chinese series on connectors for on-board electrical wiring harnesses, the part written for motorcycles and mopeds; its technical content is adopted from ISO 8092-2:1996.

It applies to blade and pin type connectors for single-wire and multi-wire harnesses of low-voltage cables, and other connector types may refer to it.

Besides defining the locking device, it sets test conditions, specimen groups and test sequence, then the tests and limits for locking strength, insertion and retention force of terminals in the housing, contact resistance, water-tightness, insulation resistance, dielectric strength, temperature rise, current cycling and ageing.

The motorcycle requirements are deliberately less severe than those of Part 1 for automobiles. It replaces QC/T 417-1999. Issued on 21 August 2001, it has applied since 1 December 2001.

Found what you need?

Document preview — QC/T 417.2-2001

National Standard of the People's Republic of China

Replacing
QC/T 417-1999

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • 1 Scope3
  • 2 Normative references3
  • 3 Definition3
  • 4 Test methods and performance requirements4
  • 5 Others21

1 Scope

This standard specifies the definition, test methods, performance requirements for connections of single-wire harness and multi-wire harness of low-voltage cable (wire) used in the electrical circuit of motorcycles and mopeds.

This standard applies to connectors of chip and column type. Other types of connectors may also make reference to this standard.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.

GB/T 2423.17-1993 Basic environmental testing procedures for electric and electronic products Test Ka: Salt mist (eqv IEC 68-2-11:1981)

GB/T 4942.2-1993 Low voltage electrical enclosure protection class (eqv IEC 947-1:1988)

JB/T 8139-1995 Road vehicles-low voltage cables(wires)

QC/T 413-1999 Basic technical requirements for automotive electric equipment

QC/T 417.1-2001 Road vehicles - Connections for on-board electrical wiring harnesses - Part 1: Definitions, test methods and general performance requirements (the automobile part)

3 Definition

This standard uses the definition of QC/T 417.1 and the following definitions.

3.1 Locking device

A device in the connector which maintains its mating portion in a mechanically automatically locked state and which is manually opened.

4 Test methods and performance requirements

4.1 General

4.1.1 Test conditions

All tests shall be carried out at room temperature (23 ± 5) °C and a relative humidity of 45% ~ 75%, unless otherwise specified.

Each test (see Table 1) shall start from a new specimen. The preparation of specimen shall comply with the relevant standards.

The connector shall be tested together with its mating portion. The connector shall be crimped to the corresponding wire. The wire used shall comply with the provisions of JB/T 8139. The specifications of all the wires used shall be recorded in the test report.

Various test methods and test samples shall affect each other. For example, in a high temperature chamber, the test samples shall be kept at a distance from each other and cannot be in contact with each other.

4.1.2 Test sequence

The test sequence for each of the specimen groups in Table 1 is represented by Xs from top to bottom.

The tests in specimen groups A, B, C, D, E, F, G, H, I apply to unsealed connectors.

The tests in specimen groups A, B, C, D, E, F, G, H, I apply to sealed connectors and splash-proof connectors.

Each specimen group shall have at least 20 sets of specimens of single-wire

For hybrid type multi-wire connectors, each type shall have at least 20 pairs of connector specimens to be tested. Each specimen group shall use the new specimen for testing.

Unless otherwise specified in the test method, at least 4 pair of connectors need to be measured in each set of multi-wire connectors. For single-wire, 2-wire, 3- direction of the connector. Maintain stability for s.

4.5.1.2 Locking of connector

After the 11th insertion as specified in 4.3.1.2, apply a force of N in the pullout direction of connector. Maintain stability for s.

4.5.2 Requirements

4.5.2.1 For the connector whose shell is locked, apply a static tension of N in the pullout direction of the connector. Maintain it for s without falling off or being damaged.

4.5.2.2 For the connector whose connection piece is locked, apply a static tension of N in the pullout direction of the connector. Maintain it for s without falling off or being damaged.

4.6 Insertion force of connector into shell

4.6.1 Test

When measuring the insertion force of the connector into the shell cavity, use the test fixture to position the connection piece along the insertion direction.

The position shall be as close as possible to the insulation reel of wire.

Use a constant speed within the range of 50 mm/min ~ 150 mm/min to insert it into the shell. The rate of application shall be recorded in the test report.

4.6.2 Requirements

After the connector is crimped to the wire as required, insert it into the shell cavity. If the nominal cross-section of the conductor of the wire as crimped by the connector is not more than 1 mm², the insertion force is at most 15 N. If the nominal cross-section of the conductor of the wire as crimped by the connector is more than 1 mm², the insertion force is at most 30 N.

4.7 Retaining force of connector in shell

4.7.1 Test

Use an appropriate test device to test the retaining force of the connector. In front of or behind the connector, apply a constant force axially and maintain it for s. The applied force shall be recorded in the test report.

4.7.2 Requirements

Insert each connector into the shell cavity. After inserting it in place, apply a constant tension of 60 N along the axial direction of the crimped connection between the connector and wire. Maintain it for s. The connector must not be removed from the shell or damaged.

Depending on the insertion/pullout force, material, design requirements, it may also require a higher retaining force.

For the sealed connector, the force as applied by the seal shall be included.

4.8 Contact resistance (voltage drop)

4.8.1 Test
4.8.1.1 Measurement at millivolt levels

The test voltage shall not exceed 20 mV of DC or AC peak voltage. The test current shall not exceed 50 mA.

As shown in Figure 2 and Figure 3, measure the contact resistance. The resistance of the associated conductor shall be subtracted from the measured value.

4.8.1.2 Measurement at specified test current

Measurements shall be made at a current intensity of 5 A/mm2 after reaching heat balance, unless otherwise specified.

If the wire used for testing is soldered to the measuring point, it shall not affect the connection of the connector.

4.8.2 Requirements

Each pair of connectors shall be inserted into the position. After the initial insertion, the contact resistance is up to 5 mohm. After 10 insertion/pullout, current cycle, temperature/humidity cycle, vibration, salt spray test, the maximum contact resistance is 10 mohm, or otherwise 150% of the initially measured value, as selected by the user.

4.9 Water-tightness

If agreed by the manufacturer and the user, for the connectors of some special purposes, the test voltage may be reduced to DC 100 V. The applied voltage shall be recorded in the test report.

When a stable reading occurs, record the insulation resistance. However, after the temperature/humidity cycle test, the unsealed and splash-proof connectors shall be placed in the conditions as specified in 4.1.1 for 24 h, before measuring the insulation resistance.

4.12.2 Requirements

According to the test sequence of Table 1, before and after the test, make determination according to 4.12.1. The insulation resistance between the connectors that are not connected in the connector as well as between the connector and the shell shall be more than 100 Mohm.

4.13 Insulation dielectric strength

4.13.1 Test

Between the connectors which are not connected in the connector as well as between the connector and the metal foil which wrap the shell, apply the AC 1000 V (50 Hz or 60 Hz) voltage or DC 1600 V voltage for 1 min. For the purposes of safety, the metal foil shall be grounded.

4.13.2 Requirements

When tested according to 4.13.1, there shall be no breakdown or sparking.

4.14 Temperature-rise

4.14.1 Test

Use the mating connector of the simulated or actual wire-wire connection (see Figure 2) or device connection (see Figure 3) to carry out the temperature-rise test.

Crimp the specimen to a wire whose nominal cross-section of conductor is not more than 2.5 mm² and length is 200 mm ± 5 mm. For cables whose conductor has a nominal cross-section of more than 2.5 mm², the length shall be 500 mm ± 2 mm.

During the test, take care to protect the sample. Prevent ventilation and manual cooling, for example, the cooling due to thermocouples.

The connector to be measured shall be able to reach the highest stable temperature. A typical measurement surface is as shown in Figure 10.

4.16.2 Requirements

After the test according to 4.16.1, it shall follow the sequence of Table 1 to carry out the subsequent tests.

4.17 Current cycle

4.17.1 Test

Use the specimen as specified in 4.14.1 to carry out the current cycle test.

According to the type of the mating connector used, based on the requirements of Table 6, specify the specification of the crimped wire of the connector and the test current.

Put the specimen into the test equipment. The temperature is as specified in Table 8. Carry out 500 cycles of tests. Each cycle consists of 45 min of power- on and 15 min of power-off.

Note: Avoid the specimen from ventilation and manual cooling.

4.18 Aging

4.18.1 Test

Put the connector in the test equipment for 100 h. The test temperature is as specified in Table 5.

Note: If using another method, that is, the test temperature as specified in Table 8, the test time needs to be increased to 500 h.

4.18.2 Requirements

Number of lines of connector Conversion factor Category Test temperature, °C (±2 °C)

7.17.2 Requirements

After the test according to 4.17.1, it shall follow the sequence of Table 1 to carry out the subsequent tests. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of QC/T 417.2

EditionTitleRevisionStatus
QC/T 417.2-2001Road vehicles - Connectors for on-board electrical wiring harnesses - Part 2: Test methods and general performance requirements (motorcycles)current editionCurrent
QC/T 417-1999Road vehicles - Connectors for on-board electrical wiring harnesses - Part 2: Test methods and general performance requirements (motorcycles)previous editionSuperseded

This page sells the current edition, QC/T 417.2-2001. Earlier editions are listed for reference only.

How to Download QC/T 417.2-2001

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QC/T 417.2-2001

$105.00