NY/T 3598-2020Fosetyl-aluminium wettable powder (English PDF)
Also coversNYT3598-2020
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for NY/T 3598-2020 in 30 minutes.
Issued by
Ministry of Agriculture and Rural Affairs of the People's Republic of China
Level / Type
National · Recommended
Issue date
March 20, 2020
Implementation date
July 1, 2020
Scope
NY/T 3598-2020 (Fosetyl-aluminium wettable powder) is available as an English-translated PDF.
NY/T 3598-2020 is the Chinese standard "Fosetyl-aluminium wettable powder". Its scope clause reads: This Standard specifies the requirements, test methods, acceptance and quality assurance periods, as well as marks, labels, packaging, storage and transportation for fosetyl-aluminium wettable powder.
This Standard applies to fosetyl-aluminium wettable powder processed from fosetyl- aluminium original drug, additives and fillers. NOTE: Please refer to Annex A for other names, structural formulas and basic physical and chemical parameters of fosetyl-aluminium.
Its clauses include acceptance and quality assurance periods. It was issued by the Ministry of Agriculture and Rural Affairs of the People's Republic of China on 2020-03-20 and took effect on 2020-07-01.
Found what you need?
Document preview — NY/T 3598-2020
National Standard of the People's Republic of China
- ICS
- 65.100.30
- Classification
- G 25
Issued by: Ministry of Agriculture and Rural Affairs of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Requirements...5
- 4 Test methods...5
- 5 Acceptance and quality assurance periods...12
- 6 Marks, labels, packaging, storage and transportation...13
1 Scope
This Standard specifies the requirements, test methods, acceptance and quality assurance periods, as well as marks, labels, packaging, storage and transportation for fosetyl-aluminium wettable powder.
This Standard applies to fosetyl-aluminium wettable powder processed from fosetyl- aluminium original drug, additives and fillers.
NOTE: Please refer to Annex A for other names, structural formulas and basic physical and chemical parameters of fosetyl-aluminium.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 601, Chemical reagent -- Preparations of reference titration solutions
GB/T 603, Chemical reagent - Preparations of reagent solutions for use in test methods
GB/T 1600, Testing method of water for pesticides
GB/T 1601, Determination method of pH value for pesticides
GB/T 1604, Commodity pesticide regulations for acceptance
GB/T 1605-2001, Sampling method for commodity pesticides
GB 3796, General rule for packing of pesticides
GB/T 5451, Testing method for the wettability of dispersible powders of pesticides
GB/T 6682, Water for analytical laboratory use -- Specification and test methods
GB/T 8170-2008, Rules of rounding off for numerical values and expression and judgement of limiting values
GB/T 14825-2006, Determination method of suspensibility for pesticides method to determine the packages to be sampled. The final sample size shall be no less than 300 g.
4.3 Identification test
4.3.1 Ion chromatography
This identification test can be carried out simultaneously with the determination of the mass fraction of fosetyl-aluminium. Under the same chromatographic operating conditions, the relative difference between the retention time of the main chromatographic peak in the specimen solution and the retention time of the ethyphosphonate chromatographic peak in the standard solution shall be within 1.5%.
4.3.2 Aluminum ion identification
Please refer to Annex B for qualitative identification of aluminum ions.
4.4 Determination of the mass fraction of fosetyl-aluminium
4.4.1 Method summary
The specimen is dissolved in mobile phase. Sodium carbonate and sodium bicarbonate solutions are used as mobile phases. Use anion chromatography column and conductivity detector to perform ion chromatography separation of ethyphosphonate in the specimen. Use the external standard method for quantification (chemical titration method can also be used to determine the mass fraction of aluminum triacetate. See
Annex C for details).
4.4.2 Reagents and solutions
Water: ultrapure.
Sodium carbonate: guaranteed pure.
Sodium bicarbonate: guaranteed pure.
Standard sample of fosetyl-aluminium: known mass fraction of fosetyl-aluminium,
omega>=97.0%.
4.4.3 Instruments
Ion chromatograph: equipped with conductivity detector and suppressor.
Integrator or electronic data acquisition system.
Chromatographic column: 250 mm × 4 mm (inner diameter) anion separation column (filled with polyvinylbenzene/ethylvinylbenzene/polyvinyl alcohol matrix, with alkyl quaternary ammonium or alkanol quaternary ammonium functional groups) and anion protection column; particle size is 6 µm (or an equivalent chromatographic column).
Weigh 0.05 g (accurate to 0. 0001 g) of fosetyl-aluminium standard sample into a 100 mL volumetric flask. Add 20 mL of water. Place in an ultrasonic cleaner and sonicate for 30 min. Cool to room temperature. Use mobile phase to dilute to volume. Shake well. Use a pipette to transfer 1 mL of the above solution into another 100 mL volumetric flask. Dilute to the graduation with mobile phase. Shake well. Filter.
4.4.5.2 Preparation of specimen solution
Weigh a specimen containing 0.05 g (accurate to 0.0001 g) of fosetyl-aluminium into a
100 mL volumetric flask. Add 20 mL of water. Place in an ultrasonic cleaner and sonicate for 30 min. Cool to room temperature. Dilute to the graduation with mobile phase. Shake well. Use a pipette to transfer 1 mL of the above solution into another 100 mL volumetric flask. Dilute to the graduation with mobile phase. Shake well. Filter.
4.4.5.3 Determination
Under the above operating conditions, after the instrument is stable, continuously inject several needles of the standard solution until the relative change in the peak area of two adjacent ethyphosphonate peaks is less than 1.5%. Measure in the order of standard sample solution, specimen solution, specimen solution, and standard sample solution.
4.4.5.4 Calculation
Average the ethosphonate peak areas in the measured two injections of sample solution and the two injections of standard solution before and after the specimen. The mass fraction of fosetyl-aluminium in the specimen is calculated according to formula (1).
Where,
omega1 - the mass fraction of fosetyl-aluminium in the specimen, in percent (%);
A2 - the average value of the ethyphosphonate peak area in the specimen solution;
m1 - the mass of the standard sample, in grams (g);
omega - the mass fraction of fosetyl-aluminium in the fosetyl-aluminium standard sample, in percent (%);
A1 - the average value of the ethyphosphonate peak area in the standard sample solution;
m2 - the mass of the specimen, in grams (g).
4.4.6 Allowable difference
The difference between the two parallel determination results of the mass fraction of fosetyl-aluminium shall be no more than 0.6% for 40% and no more than 1.0% for 80%.
Take the arithmetic mean as the measurement result.
4.5 Determination of phosphite
4.5.1 Method summary
The specimen is dissolved in mobile phase. Sodium carbonate and sodium bicarbonate solutions are used as mobile phases. Using an anion chromatography column and a conductivity detector, the phosphite in the specimen is separated by ion chromatography.
Conduct quantification by external standard method.
4.5.2 Reagents and solutions
Water: ultrapure.
Sodium carbonate: guaranteed pure.
Sodium bicarbonate: guaranteed pure.
Sodium phosphite pentahydrate standard: known mass fraction omega>=98.0%.
4.5.3 Instruments
Ion chromatograph: equipped with conductivity detector and suppressor.
Integrator or electronic data acquisition system.
Chromatographic column: 250 mm × 4 mm (inner diameter) anion separation column (filled with polyvinylbenzene/ethylvinylbenzene/polyvinyl alcohol matrix with alkyl quaternary ammonium or alkanol quaternary ammonium functional groups) and anion protection column; particle size is 6 µm (or an equivalent chromatographic column).
Filter: the pore size of the filter membrane is approximately 0.45 µm.
Microsampler: 50 µL.
Quantitative injection tube: 5 µL.
Ultrasonic cleaner.
4.5.4 Ion chromatography operating conditions
Mobile phase: carbonate eluent [c(Na2CO3) = 4.5 mmol/L + c (NaHCO3) = 0.8 mmol/L].
Weigh 477 mg of sodium carbonate and 67.2 mg of sodium bicarbonate and dissolve them in 1000 mL of water. Mix well.
Flow rate: 0. 8 mL/min.
4.6 Moisture
In accordance with the provisions of GB/T 1600.
4.7 pH
In accordance with the provisions of GB/T 1601.
4.8 Determination of suspension rate
Weigh a specimen containing 0.5 g of fosetyl-aluminium (accurate to 0.0001 g). Follow the provisions of 4.1 in GB/T 14825-2006. Use mobile phase to transfer the remaining
1/10 of the suspension to a 200 mL volumetric flask. Determine the mass fraction of fosetyl-aluminium according to 4.4. Calculate the suspension rate.
4.9 Determination of wetting time
Follow the provisions of GB/T 5451.
4.10 Wet screening test
Follow the provisions of 2.2 in GB/T 16150-1995.
4.11 Determination of persistent foaming properties
Follow the provisions of GB/T 28137.
4.12 Determination of thermal storage stability
Follow the provisions of 2.3 in GB/T 19136-2003. After thermal storage, the mass fraction of fosetyl-aluminium shall not be lower than 95% of that before storage. The pH, suspension rate, wetting time and wet screening test shall still meet the standard requirements to be qualified.
5 Acceptance and quality assurance periods
5.1 Acceptance
It shall comply with the provisions of GB/T 1604.
5.2 Quality assurance periods
Under the specified storage and transportation conditions, the quality assurance period for fosetyl-aluminium wettable powder is 2 years from the production date. During the quality assurance period, all indicators shall comply with standard requirements.
Annex B (informative)
Aluminum ion complex titration method
B.1 Principle
The determination of aluminum ions in fosetyl-aluminium samples adopts the complexometric titration method. That is, the fosetyl-aluminium sample is decomposed in an excess CDTA standard solution under acid and heating conditions; aluminum ions form a complex with CDTA; the excess CDTA standard solution is back-titrated with a zinc sulfate standard titration solution.
B.2 Reagents and solutions
Perchloric acid.
Xylenol orange.
Hexamethylenetetramine (HMTA).
1,2-Cyclohexanediaminetetraacetic acid (CDTA).
Sodium hydroxide.
Zinc sulfate standard titration solution: c(ZnSO4) = 0.05 mol/L.
Potassium nitrate.
Deionized water.
B.3 Instruments
150 mL beakers.
20 mL pipettes.
Automatic potentiometric titrator.
Magnetic stirrer with heating.
B.4 Operation steps
B.4.1 Preparation of CDTA standard solution
Weigh 8.5 g of sodium hydroxide into a 2 L volumetric flask. Add 500 mL of water to dissolve. Weigh out another 36.4 g of CDTA. Dissolve with heat. After cooling to room temperature, dilute to the graduation with water.
B.4.2 Preparation of perchloric acid solution
In a 500 mL beaker with 300 mL of water previously added, add 100 mL of perchloric acid while stirring.
B.4.3 Preparation of grinding indicator
Weigh 0.1 g of xylenol orange and 9.9 g of potassium nitrate and grind in a mortar until completely mixed.
B.4.4 Determination of blank CDTA standard solution
Use a pipette to transfer 20 mL of CDTA standard solution into a 250 mL Erlenmeyer flask. Add 20 mL of water to dilute. Add 5 mL of perchloric acid solution. Heat to boiling for about 1 min.
After cooling to room temperature, add 6.0 g of HMTA. Stir until completely dissolved.
Add 30 mg ~ 50 mg of grinding indicator. Titrate with zinc sulfate standard titration solution until the solution changes from yellow to red as the end point.
Repeat the determination three times.
B.4.5 Determination of sample
Weigh a specimen containing 0.1 g of fosetyl-aluminium (accurate to 0. 0001 g) into a
250 mL beaker. Add 20 mL of water. Add 5 mL of perchloric acid solution. Heat to boiling for about 1 min.
Add exactly 20 mL of CDTA standard solution. Heat to boiling for about 1 min. After cooling to room temperature, add 6.0 g of HMTA. Stir until completely dissolved. Add
30 mg ~50 mg of grinding indicator. Titrate with zinc sulfate standard titration solution until the solution changes from yellow to red as the end point.
B.5 Calculation of aluminum ions
The mass fraction of aluminum ions is calculated according to formula (B.1).
Where,
omega4 - the mass fraction of aluminum in the specimen, in percent (%);
V0 - the average value of the zinc sulfate standard titration solution volume consumed
Buffer solution: pH=7.3±0.2. Weigh 100 g of sodium hydroxide (accurate to 0. 0002 g) into a 2000 mL beaker. Add 1.8 L of water to dissolve. Neutralize to pH=8.0 with phosphoric acid solution. After cooling to room temperature, neutralize with phosphoric acid solution to pH=7.3±0.2. Add 30 g of potassium iodide and 20 mL of iodine standard titration solution. Stir to dissolve and transfer to a 2000 L volumetric flask.
Dilute to the graduation. Store in dark place at room temperature. Before use, titrate with sodium thiosulfate standard titration solution until colorless.
C.3 Instruments
Potentiometric titrator.
Ultrasonic water bath.
pH meter.
Adjustable heating mantle.
Spherical condenser tube.
Iodine vial: 250 mL.
Burette: 25 mL, brown.
C.4 Determination steps
C.4.1 Specimen solution
Weigh a specimen containing 3 g of fosetyl-aluminium (accurate to 0. 0001 g) and place it in a 500 mL volumetric flask. Add 200mL of sodium hydroxide B solution. Place the volumetric flask in an ultrasonic water bath and sonicate for 10 min. After cooling to room temperature, add sodium hydroxide A solution to the volume and mix well. Use a pipette to transfer 10 mL of the specimen solution into a 250 mL iodine flask. Add 40 mL of sodium hydroxide A solution. Connect to condenser pipe. Heat to boil and reflux for 1 h. Flush the condenser tube with a small amount of water. Cool to room temperature. Neutralize with sulfuric acid solution. Add 2 drops of phenolic acid indicator near the end point. Continue titration until the red color disappears.
C.4.2 Determination
Use a pipette to add 25 mL of buffer solution and 20 mL of iodine standard titration solution. Cap the bottle and mix well. Seal with water. Place the iodine bottle in a dark place for 30 min ~ 45 min. Add 3 mL of acetic acid to acidify. Titrate with sodium thiosulfate standard titration solution. Add 3 mL of starch indicator near the end point.
Continue titrating until the blue color of the solution disappears as the end point (or use a potentiometric titrator to determine the end point).
C.4.3 Blank determination
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 601Chemical Reagent - Preparations of Standard Volumetric Solutions
- GB/T 603Chemical reagent - Preparations of reagent solutions for use in test methods
- GB/T 1600Testing method of water for pesticides
- GB/T 1601Determination method of pH value for pesticides
- GB/T 1604Commodity pesticide regulations for acceptance
- GB 3796General rule for packing of pesticides
GB/T 1605-2001
How to Download NY/T 3598-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 3796-2018 — General rule for packing of pesticides
GB/T 1600-2021 — Testing method of water for pesticides
GB/T 16006-2025 — Elimination of iodine deficiency disorders
Secure payment via Stripe
Payments accepted
NY/T 3598-2020
$220.00