JJF 1793-2020Calibration Specification for Seawater Nutrients Analyzers (English PDF)
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1793-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1793-2020 (Calibration Specification for Seawater Nutrients Analyzers) is available as an English-translated PDF.
JJF 1793-2020 is the Chinese standard "Calibration Specification for Seawater Nutrients Analyzers".
Found what you need?
Document preview — JJF 1793-2020
National Standard of the People's Republic of China
- ICS
- 17.180
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Overview (1)
- 4 Measurement characteristics (1)
- 4.1 Detection limit (1)
- 4.2 Indication error (1)
- 4.3 Measurement repeatability (1)
- 5 Calibration conditions (1)
- 5.1 Calibration environmental conditions (1)
- 5.2 Measurement standards and other equipment (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Calibration items (2)
- 6.2 Calibration method (2)
- 7 Expression of calibration results (3)
- 7.1 Calibration record (3)
- 7.2 Calibration result processing (3)
- 8 Recalibration interval (4)
- Appendix A Calibration Record Form of Seawater Nutrient Salt Meter (5)
- Appendix B The format of the inner page of the calibration certificate of the seawater nutrient salt meter (7)
- Appendix C Measurement Uncertainty Evaluation Example of Calibration Results of Nutrient Salt Concentration Indication Error (8)
1 Scope (1)
2 Reference documents (1)
3 Overview (1)
4 Measurement characteristics (1)
4.1 Detection limit (1)
4.2 Indication error (1)
4.3 Measurement repeatability (1)
5 Calibration conditions (1)
5.1 Calibration environmental conditions (1)
5.2 Measurement standards and other equipment (2)
6 Calibration items and calibration methods (2)
6.1 Calibration items (2)
6.2 Calibration method (2)
7 Expression of calibration results (3)
7.1 Calibration record (3)
7.2 Calibration result processing (3)
8 Recalibration interval (4)
Appendix A Calibration Record Form of Seawater Nutrient Salt Meter (5)
Appendix B The format of the inner page of the calibration certificate of the seawater nutrient salt meter (7)
Appendix C Measurement Uncertainty Evaluation Example of Calibration Results of Nutrient Salt Concentration Indication Error (8)
Introduction
This specification is based on JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1059.1-2012 "Inaccurate Measurement "Quality Evaluation and Representation" and JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications" are the basic series of specifications Make it.
This specification combines the development and application status of seawater nutrient salt measuring instruments, and refers to HY/T 099-2007 seawater Part of the content of the detection method of the nutrient salt meter is formulated.
This specification is released for the first time.
Calibration specification for seawater nutrient salt meter
1 Scope
This specification is applicable to the calibration of nutrient salt meters used in marine field.
2 Reference documents this specification refers to the following documents.
HY/T 099-2007 seawater nutrient salt measuring instrument testing method for dated reference documents, only the dated version applies to this specification; for undated references the latest version (including all amendments) is applicable to this specification.
3 overview
The nutrients referred to in this specification are nitrate, nitrite, ammonia-nitrogen, phosphate and silicate in seawater.
Inorganic salts needed for the growth of foreign plants.
Seawater nutrient salt measuring instrument (hereinafter referred to as "measuring instrument") is used to measure the nutrient salt concentration in seawater on-site, which can Automatic or semi-automatic injection, quantitative addition of reagents, chemical reactions and measurement. The measuring instrument mostly adopts the colorimetric method.
Measure the degree of absorption of light waves by sea water samples, and analyze the nutrient concentration of sea water samples.
4 Measurement characteristics
4.1 Detection limit
Nitrate-nitrogen should not exceed 4µg/L; nitrite-nitrogen and phosphate-phosphorus should not exceed 1µg/L; ammonia-nitrogen should not exceed More than 3µg/L; silicate-silicon should not exceed 6µg/L.
4.2 Indication error Relative error of indication. nitrate-nitrogen, nitrite-nitrogen, phosphate-phosphorus, silicate-silicon should not exceed the measured value ±10% of the measured value; ammonia-nitrogen should not exceed ±15% of the measured value.
When the indication value of the measuring instrument is within 10% of its measuring range, the indication error of nitrate-nitrogen and ammonia-nitrogen should not exceed 5µg/L; nitrite-nitrogen, phosphate-phosphorus, silicate-silicon should not exceed ±3µg/L.
4.3 Measurement repeatability Nitrate-nitrogen, nitrite-nitrogen, phosphate-phosphorus, silicate-silicon and ammonia-nitrogen measurement repeatability should not be greater than 3%.
Note. All the above indicators are not used as eligibility judgments, only for reference.
5 Calibration conditions
5.1 Calibration environment conditions Ambient temperature. (20±5)°C;
Relative humidity. 20%~80%;
Others. There is no mechanical vibration or electromagnetic interference that affects the normal operation of the measuring instrument.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
Referenced standards
How to Download JJF 1793-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1793-2020
$225.00