JJF 1792-2020Calibration Specification for Seawater pH Analyzers (English PDF)
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1792-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1792-2020 (Calibration Specification for Seawater pH Analyzers) is available as an English-translated PDF.
JJF 1792-2020 is the Chinese standard "Calibration Specification for Seawater pH Analyzers".
Found what you need?
Document preview — JJF 1792-2020
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Overview (1)
- 4 Measurement characteristics (1)
- 5 Calibration conditions (1)
- 5.1 Calibration environmental conditions (1)
- 5.2 Measurement standards and other equipment (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Calibration items (2)
- 6.2 Calibration method (2)
- 7 Expression of calibration results (3)
- 7.1 Calibration record (3)
- 7.2 Processing of calibration results (3)
- 8 Recalibration interval (4)
- Appendix A Special container for calibration of seawater pH meter (5)
- Appendix B Calibration Record Form of Seawater pH Meter (6)
- Appendix C Format of the inner page of the calibration certificate of seawater pH meter (8)
- Appendix D Measurement Uncertainty Evaluation Example of Calibration Results of pH Indication Error (9)
1 Scope (1)
2 Reference documents (1)
3 Overview (1)
4 Measurement characteristics (1)
5 Calibration conditions (1)
5.1 Calibration environmental conditions (1)
5.2 Measurement standards and other equipment (2)
6 Calibration items and calibration methods (2)
6.1 Calibration items (2)
6.2 Calibration method (2)
7 Expression of calibration results (3)
7.1 Calibration record (3)
7.2 Processing of calibration results (3)
8 Recalibration interval (4)
Appendix A Special container for calibration of seawater pH meter (5)
Appendix B Calibration Record Form of Seawater pH Meter (6)
Appendix C Format of the inner page of the calibration certificate of seawater pH meter (8)
Appendix D Measurement Uncertainty Evaluation Example of Calibration Results of pH Indication Error (9)
Introduction
This specification is based on JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1059.1-2012 "Inaccurate Measurement Standardized Evaluation and Representation" and JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications" are the basic series of specifications Make it.
This specification combines the development and application status of seawater pH measuring instruments, and refers to JJF 1547-2015 "Online pH Part of the content of the "Gauge Calibration Specification" will be formulated.
This specification is released for the first time.
Calibration specification for seawater pH meter
1 Scope
This specification applies to the calibration of seawater pH meters.
2 Reference documents this specification refers to the following documents.
JJF 1547-2015 Online pH Meter Calibration Specification HY/T 098-2007 Seawater pH meter testing method OIMLR54 (1980) pH value of aqueous solution (pHScaleforAqueousSolutions) for dated reference documents, only the dated version applies to this specification; for undated references the latest version (including all amendments) is applicable to this specification.
3 overview
The seawater pH meter refers to an instrument used to measure the pH value of seawater (hereinafter referred to as "meter"). Such instruments Composed of pH sensor, temperature probe and host, it can be directly placed in sea water for measurement, generally integrated in multi-parameter water quality on marine monitoring equipment such as instruments or buoys, it has the characteristics of online real-time continuous measurement without sampling. Based on electrochemistry the working principle of the basic measuring instrument is to convert the hydrogen ion concentration in seawater into the corresponding electrical signal through the sensing element.
The pH value is displayed after analog-to-digital conversion and data processing.
4 Measurement characteristics the measurement characteristics of the measuring instrument are listed in Table 1.
Table 1 Measurement characteristics of the measuring instrument
Item measurement performance
1 The error of pH indication should not exceed ±0.1
2 The pH indication error caused by temperature compensation should not exceed ±0.1
3 The temperature indication error should not exceed ±0.5°C
4 The repeatability of pH indication should not exceed 0.03 Note. All the above indicators are not used as eligibility judgments, only for reference.
5 Calibration conditions
5.1 Calibration environment conditions Ambient temperature. (23±10)°C;
Relative humidity. 20%~80%;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
Referenced standards
How to Download JJF 1792-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1792-2020
$255.00