JB/T 9662-2011Closed insulated busbar trunking systems (closed insulated busways) (English PDF)
密集绝缘母线干线系统(密集绝缘母线槽)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 9662-2011 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
December 20, 2011
Implementation date
April 1, 2012
Scope
JB/T 9662-2011 is the English-translated version of 密集绝缘母线干线系统(密集绝缘母线槽).
JB/T 9662-2011 is a recommended Chinese machinery industry standard for closed insulated busbar trunking systems. It covers the terms and definitions, the technical requirements, the test methods, the inspection rules, marking, packaging, transport and storage.
It applies to busways with a rated voltage not exceeding 1 000 V, 1 140 V included, at 50 Hz or 60 Hz, installed in residential, commercial, public, agricultural and industrial buildings, to lighting busbar systems fed through tap-off units, and to busbar systems used with communication or control systems.
Self-contained components fitted into a busway, such as circuit breakers, follow their own standards. It supersedes JB/T 9662-1999 and cites GB 4208-2008, GB 7251.1-2005, GB 7251.2-2006 and JB/T 3085.
Found what you need?
Document preview — JB/T 9662-2011
National Standard of the People's Republic of China
- ICS
- 29.120
- Replacing
- JB/T 9662-1999
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- [Preview only]
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Technical requirements
- 4.1 General requirements
- 4.2 Model designation
- 6 Test methods
- 6.1 Factory inspection
- 6.2 Type inspection
- 7 Inspection rules
- 8 Marking, packaging, transportation and storage
- 8.1 Marking
- 8.2 Packaging
1 Foreword
JB/T 9662-2011 was issued by Ministry of Industry and Information Technology of the People's Republic of China on 20 December 2011 and has been in force since 1 April 2012.
It replaces the earlier edition JB/T 9662-1999.
The JB/T prefix marks a recommended standard. It is not law in itself: it becomes binding when a contract names it, when a regulation or a mandatory standard refers to it, or when a producer declares conformity with it.
2 Scope Preview
This standard is a recommended Chinese machinery industry standard for closed insulated busbar trunking systems. It covers the terms and definitions, the technical requirements, the test methods, the inspection rules, marking, packaging, transport and storage. It applies to busways with a rated voltage not exceeding 1 000 V, 1 140 V included, at 50 Hz or 60 Hz, installed in residential, commercial, public, agricultural and industrial buildings, to lighting busbar systems fed through tap-off units, and to busbar systems used with communication or control systems. Self-contained components fitted into a busway, such as circuit breakers, follow their own standards. It supersedes JB/T 9662-1999 and cites GB 4208-2008, GB 7251.1-2005, GB 7251.2-2006 and JB/T 3085.
JB/T 9662-2011 falls under ICS 29.120, in the field of electrical engineering.
This catalogue holds 619 other JB/T standards in that field.
In this catalogue, JB/T standards carry edition years from 1967 to 2026.
3 Normative references
GB 4208-2008 — Degrees of Protection Provided By Enclosure (IP Code)
GB 7251.1-2005 — Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies
GB 7251.2-2006 — Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways)
JB/T 3085
4 About this standard
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
English translation: about 15 pages
5 Related standards
Other editions:
JB/T 9662-1999 (earlier edition)
Standards on related subjects:
GB/T 7251.2-2023 — Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies
GB/T 7251.6-2015 — Low-voltage switchgear and controlgear assemblies -- Part 6: Busbar trunking systems (busways)
GB 7251.12-2013 — [GB/T 7251.12-2013] Low-voltage switchgear and controlgear assemblies -- Part 2: Power switchgear and controlgear assemblies
JB/T 3907-2025 — Machine tool electric apparatus - Push-button switches
JB/T 7845-2025 — Electronic control equipment for land drilling rigs
JB/T 9665-2013 — Type designation method for auxiliaries of low-voltage switchgear and controlgear assemblies
6 Classification and status
International classification (ICS): 29.120
Chinese Standard Classification (CCS): K 31
Prefix JB/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 4208-2008Degrees of Protection Provided By Enclosure (IP Code)
- GB 7251.1-2005Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies
- GB 7251.2-2006Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways)
- JB/T 3085Code for packaging and transportation of electric drive control equipment
Similar standards
Editions of JB/T 9662
| Edition | Title | Revision | Status |
|---|---|---|---|
| JB/T 9662-2011 | Closed insulated busbar trunking systems (closed insulated busways) | current edition | Current |
| JB/T 9662-1999 | Closed insulated busbar trunking systems (closed insulated busways) | previous edition | Superseded |
This page sells the current edition, JB/T 9662-2011. Earlier editions are listed for reference only.
How to Download JB/T 9662-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4208-2008 — Degrees of Protection Provided By Enclosure (IP Code)
GB 7251.1-2005 — Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies
GB 7251.2-2006 — Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways)
JB/T 9662-2011
$195.00