Valid

JB/T 8145.2-1995Cables (wires) for railway rolling stock of AC rated voltages up to and including 3 kV - Chlorosulfonated polyethylene insulated cables (wires) for railway rolling stock (English PDF)

交流额定电压3kV 及以下铁路机车车辆用电缆(电线) 氯磺化聚乙烯绝缘铁路机车车辆用电缆 (电线)

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JB/T 8145.2-1995 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

October 10, 1995

Implementation date

October 10, 1995

Scope

JB/T 8145.2-1995 is the English-translated version of 交流额定电压3kV 及以下铁路机车车辆用电缆(电线) 氯磺化聚乙烯绝缘铁路机车车辆用电缆 (电线).

JB/T 8145.2-1995 is the Chinese standard "Cables (wires) for railway rolling stock of AC rated voltages up to and including 3 kV - Chlorosulfonated polyethylene insulated cables (wires) for railway rolling stock".

Its scope clause reads: This Standard specifies the product types, technical requirements and inspection rules of chlorosulphonated polyethylene insulated cables (wires) for railway vehicles.

This Standard applies to chlorosulphonated polyethylene insulated cables (wires) for railway vehicles of rated voltages up to and including 750 V. Besides conforming to the requirements prescribed in this Standard, cables (wires) shall also comply with the provisions of GB 12528.1.

Its clauses include subject content and application scope; service characteristics; models.

Found what you need?

Document preview — JB/T 8145.2-1995

National Standard of the People's Republic of China

Replacing
GB 12528.3-1990

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • 1 Subject content and application scope3
  • 2 Service characteristics3
  • 3 Models3
  • 4 Specifications4
  • 5 Technical requirements4
  • 6 Test6
  • Additional information:9

1 Subject content and application scope

This Standard specifies the product types, technical requirements and inspection rules of chlorosulphonated polyethylene insulated cables (wires) for railway vehicles.

This Standard applies to chlorosulphonated polyethylene insulated cables (wires) for railway vehicles of rated voltages up to and including 750 V.

Besides conforming to the requirements prescribed in this Standard, cables (wires) shall also comply with the provisions of GB 12528.1.

2 Service characteristics

2.1

Rated voltage is 750 V.

2.2

Long-term allowable working temperature of cable:

DCH/3 shall not be greater than 70 °C;

DCH/3-100 shall not be greater than 100 °C.

2.3

Cables may be used at the occasions where is contaminated by mineral oil and fuel oil.

2.4

Allowable bending radius for cable laying:

It shall not be less than 3 D, for outer diameter of cable (D) of 20mm or below;

It shall not be less than 5 D, for outer diameter of cable (D) of 20mm or above.

3 Models

Cable models are shown in Table 1.

1.0 A 1.2 4.4

B 1.2 4.4

1.5 A 1.2 4.7

B 1.2 4.7

2.5 A 1.2 5.2

B 1.2 5.2

4

A 1.2 6.0

B 1.2 6.0

6

A 1.2 7.4

B 1.2 7.4

10

A 1.4 9.0

B 1.4 9.0

16

A 1.4 10.5

B 1.4 10.0

25

A 1.6 12.5

B 1.6 12.5

35

A 1.6 14.0

B 1.6 14.0

Table 3 (Continued)

Nominal

Cross-Section of

Conductor mm

2

Specifications of

Conductor

Insulated Nominal Thickness mm

Upper Limit of Average Outer

Diameter mm

50

A 1.8 16.5

B 1.8 16.0

70

A 1.8 18.5

B 1.8 18.0

95

A 2.0 20.5

B 2.0 20.5

120 A 2.0 22.5 […]

3.4 Fuel oil resistance test

Conforming to the provisions in clause 3 in Table 4 of GB 12528.1

T, S

GB 2951.15 and GB 12528.1 Annex B

3.5 Ozone resistance test

Conforming to the provisions in clause 4 in Table 4 of GB 12528.1

T, S GB 2951.35

3.6

3.6.1

3.6.2 Low-temperature winding

test.

Low-temperature winding test for untreated samples.

Low-temperature winding test for samples after aging in air tank.

Conforming to the provisions in clause 6 in Table 4 of GB 12528.1

T, S GB 2951.12

3.7

3.7.1

Low-temperature tensile test.

Low-temperature tensile test for untreated samples.

Conforming to the provisions in clause 7 in Table 4 of GB 12528.1

T, S GB 2951.13

Table 4 (Continued)

No. Item Name Technical Requirements

Test

Type

Test Method

3.7.2 Low-temperature tensile test

for samples after aging in air tank

4

4.1.

4.2

4.3

Combustion test.

Combustion test for untreated samples.

Combustion test for samples after treatment of immersion in mineral oil.

Combustion test for samples after treatment of immersion in fuel oil.

Conforming to the provisions in clause 5.5 of GB 12528.1

T, S Clause 5.4.5 in GB 12528.1

5

Rub resistance test of printing mark

Conforming to the provisions in clause 8.1 of GB 12528.1

T, S

Clause 8.1.2 in GB 12528.1

____________________

Additional information:

This Standard was proposed by Ministry of Machine Building and Electronics Industries of the People’s Republic of China and shall be under the jurisdiction of MMBEI Shanghai

Electric Cable Research Institute.

This Standard is responsibly drafted by MMBEI Shanghai Electric Cable Research

Institute, etc.

Main drafters of this Standard: Xin Jiming, Sun Zhenghua, Li Xueming, Liu Suilin and

Zhang Jinglin.

__________ END __________ […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of JB/T 8145.2

EditionTitleRevisionStatus
JB/T 8145.2-1995Cables (wires) for railway rolling stock of AC rated voltages up to and including 3 kV - Chlorosulfonated polyethylene insulated cables (wires) for railway rolling stockcurrent editionCurrent
GB 12528.3-1990Cables (wires) for railway rolling stock of AC rated voltages up to and including 3 kV - Chlorosulfonated polyethylene insulated cables (wires) for railway rolling stockprevious editionSuperseded

This page sells the current edition, JB/T 8145.2-1995. Earlier editions are listed for reference only.

How to Download JB/T 8145.2-1995

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 8145.2-1995