JB/T 4119-2013Solenoid valves for refrigeration (English PDF)
制冷用电磁阀
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for JB/T 4119-2013 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
April 25, 2013
Implementation date
September 1, 2013
Scope
JB/T 4119-2013 is the English-translated version of 制冷用电磁阀.
Solenoid valves for refrigeration equipment are the subject of JB/T 4119-2013. The standard gives terms and definitions, the type, model and basic parameters, the requirements, the test methods, the inspection rules and the provisions on marking, packaging, transportation and storage. It applies to solenoid valves of nominal diameter not greater than 40 mm whose pipes and high and low pressure steam pipes use R22, R134a, R404A, R407C or R410A as the refrigerant; valves working with other refrigerants may refer to it. The standard replaces JB/T 4119-1991, was issued on 25 April 2013 and implemented on 1 September 2013.
Found what you need?
Document preview — JB/T 4119-2013
National Standard of the People's Republic of China
- Replacing
- JB/T 4119-1991
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword4
- 1 Scope5
- 2 Normative references5
- 3 Terms and definitions6
- 4 Type, model and basic parameters7
- 4.1 Type7
- 4.2 Model7
- 4.3 Basic parameters8
- 4.4 Working conditions8
- 5 Requirements9
- 5.1 General requirements9
- 5.2 Dimension requirements9
- 5.3 Material requirements9
- 5.4 Appearance requirements10
- 5.5 Performance requirements10
- 5.6 Breaking strength12
- 6 Test method13
- 6.1 Test requirements13
- 6.2 Dimensional inspection14
- 6.3 Material inspection14
- 6.4 Visual inspection14
- 6.5 Performance requirement test14
- 6.6 Breaking strength test18
- 7 Inspection rules18
- 7.1 General requirements18
- 7.2 Inspection classification19
- 7.3 Ex-factory inspection19
- 7.4 Sampling inspection20
- 7.5 Type inspection20
- 8 Marking, packaging, transportation and storage20
- 8.1 Marking20
- 8.2 Packaging21
- 8.3 Transportation21
- 8.4 Storage21
Foreword
This Standard is drafted according to the rules specified in GB/T 1.1-2009. This Standard replaces GB/T 4119-1991 "Solenoid Valve For Refrigeration Equipment". Compared with GB/T 4119-1991, main technical changes are as follows.
- Revise the rang of application (see chapter 1, chapter 1 in edition 1991);
- Revise terms and definitions (see chapter 3, chapter 3 in edition 1991);
- Revise the basic parameters of solenoid valve;
- Increase the requirements on dimension, material, appearance, level of protection, high temperature resistance, low temperature resistance, corrosion resistance, cleanliness, noise, breaking strength;
- Revise the requirements on tightness, maximum opening pressure differential, internal leakage rate, insulation resistance, electrical strength, heat and humidity resistance, vibration resistance, durability and flow rate;
- Revise the tightness, maximum opening pressure differential, internal leakage rate, insulation resistance, insulation resistance, electrical strength, heat and humidity resistance, durability and flow rate test method.
1 Scope
This Standard specifies terms and definitions, types, models and basic parameters, requirements, test methods, inspection rules, marking, packaging, transportation, and storage of solenoid valve for refrigeration equipment (hereinafter referred to as "solenoid valve").
This Standard applies to solenoid valve, of which the nominal diameter is not greater than 40 mm, and of which the pipes, high-and-low pressure steam pipes use R22, R134a, R404A, R407C and R410A as the refrigerants. Solenoid valves of using other refrigerants may reference to this Standard for use.
2 Normative references
The articles contained in the following documents have become part of this document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 2423.1 Environmental testing - Part 2: Test methods - Tests A. Cold
GB/T 2423.2 Environmental testing - Part 2: Test methods - Tests B. Dry heat
GB/T 2423.3 Environmental testing for electric and electronic products - Part 2: Testing method test Cab. Damp heat Steady state
GB/T 2423.17 Environmental testing for electric and electronic products - Part 2: Test method - Test Ka. Salt mist
GB/T 2624(All parts) Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full
GB/T 10567.2 Wrought copper and copper alloys - Detection of residual stress - Ammonia test
GB/T 13306 Plates
GB 14536.1 Automatic electrical controls for household and similar use - Part 1: General requirements
JB/T 5296 Valves for general purposes - Test method of flow coefficient and flow resistance coefficient
3 Terms and definitions
Following terms and definitions apply to this document.
3.1 Solenoid valve for refrigeration equipment
The valve that utilizes the electromagnetic force generated by the coil energized excitation to drive the valve element to open or close.
3.2 Direct action-type solenoid valve
The valve that is opened and closed by utilizing the electromagnetic force generated by coil energized excitation to directly drive the valve element to realize open-close.
3.3 Pilot-type solenoid valve
The valve that utilizes the electromagnetic force generated by the coil energized excitation to drive pilot valve; then through the pilot pressure, open and close the main valve by the pressure differential of upper-lower parts of valve element.
3.4 Normally closed solenoid valve
The valve that is closed when coil is not energized, and opened when coil is energized.
3.5 Normally open solenoid valve
The valve that that is opened when coil is not energized, and closed when coil is energized.
3.6 Maximum working pressure
The allowable maximum working pressure when solenoid valve is operated.
3.7 Maximum opening pressure differential
The maximum pressure differential, between valve inlet and outlet, that enables solenoid valve to open reliably.
3.8 Minimum opening pressure differential
The minimum pressure differential, between valve inlet and outlet, that enables solenoid valve to open reliably.
3.9 Pressure drop
The pressure differential that refrigerant passes inlet and outlet of solenoid valve.
3.10 Internal leakage rate
Under specified test conditions, the flow rate when test medium passes through valve's close-position. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 2423.17Environmental testing - Part 2: Test methods - Test Ka: Salt mist
- GB/T 10567.2Wrought copper and copper alloys - Detection of residual stress - Ammonia test
- GB/T 13306Plates
- JB/T 5296General purpose valves - Test methods for flow coefficient and flow resistance coefficient
GB/T 2423.1 · GB/T 2423.2 · GB/T 2423.3 · GB/T 2624 · GB 14536.1
Similar standards
Editions of JB/T 4119
| Edition | Title | Revision | Status |
|---|---|---|---|
| JB/T 4119-2013 | Solenoid valves for refrigeration | current edition | Current |
| JB/T 4119-1991 | Solenoid valves for refrigeration | previous edition | Superseded |
This page sells the current edition, JB/T 4119-2013. Earlier editions are listed for reference only.
How to Download JB/T 4119-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10567.2-2007 — Wrought copper and copper alloys - Detection of residual stress - Ammonia test
GB/T 13306-2011 — Plates
GB/T 191-2025 — Graphical symbols marking for handling and storage of packages
Secure payment via Stripe
Payments accepted
JB/T 4119-2013
$130.00