Valid

JB/T 20199-2021Automatic decoction systems for traditional Chinese medicine (English PDF)

中药自动化煎制系统

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JB/T 20199-2021 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

August 21, 2021

Implementation date

February 1, 2022

Scope

JB/T 20199-2021 is the English-translated version of 中药自动化煎制系统.

Hospital pharmacies and decoction centres that prepare herbal decoctions by machine work to JB/T 20199-2021, the Chinese machinery industry standard for automatic decoction systems for traditional Chinese medicine.

The system it describes covers the whole chain: receiving and checking prescriptions, dispensing, soaking, decocting, concentrating, transporting the dregs, cleaning and packaging.

Materials touching the process medium must be non-toxic, corrosion-resistant and free of chemical reaction or adsorption with the drug.

Appearance rules ask for smooth, densely coated outer surfaces, a roughness Ra no greater than 0.8 µm on metal parts in contact with the drug, legible instrument markings and pipelines labelled with fluid name and flow direction.

Test methods draw on GB/T 30219, JB/T 20116, GB/T 36035 and the 2020 Pharmacopoeia. It was issued on 21 August 2021 and has applied since 1 February 2022.

Found what you need?

Document preview — JB/T 20199-2021

National Standard of the People's Republic of China

Classification
C 93

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Requirements

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.

1 Scope

This document specifies the terms, definitions, requirements and test methods of the automatic decoction system for traditional Chinese medicine.

This document is applicable to the automatic decoction system of traditional Chinese medicine decoction.

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.

GB/T 3768 Acoustic sound pressure method to measure noise source power and sound energy level

GB/T 12803 Laboratory glass instrument measuring cup

GB/T 30219-2013 Traditional Chinese Medicine Decoction Machine

GB/T 31773 Traditional Chinese Medicine Prescription Coding Rules and Coding

GB/T 36035 General Requirements for Electrical Safety of Pharmaceutical Machinery

JB/T 20116 Traditional Chinese Medicine Decoction Packaging Machine Pharmacopoeia of the People's Republic of China (2020 Edition I) (State Pharmacopoeia Commission)

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Automatic decoction system for traditional Chinese medicine

It is an automatic decoction system that realizes the whole process of traditional Chinese medicine from receiving, examining, dispensing, soaking, decocting, concentrating, dregs transportation, cleaning to packaging.

4 Requirements

4.1 Materials

Check the material quality certification materials, if the material cannot be proved, test according to the test method of the corresponding material.

The materials of the parts that are in direct contact with the required process medium should be non-toxic, corrosion-resistant, not falling off, and not related to the decocted drugs (materials) or have requirements. chemical reaction or adsorption of the process medium.

4.2 Appearance

4.2.1 The outer surface of the equipment of the automatic decoction system for traditional Chinese medicine (hereinafter referred to as the "decocting system") should be smooth and flat, and the coated surface should be The coating should be dense and not fall off.

4.2.2 The surface roughness Ra value of metal parts in direct contact with the drug (material) shall not be greater than 0.8 µm when detected with a surface roughness meter.

4.2.3 The identification of visual inspection instruments and operating parts shall be clear.

4.2.4 The liquid and gas pipelines of the visual inspection system should be arranged neatly, and the name and flow direction of the fluid in the pipeline should be marked at the pipeline interface.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download JB/T 20199-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 20199-2021

$105.00