JB/T 10491.2-2004Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750 V - Part 2: Cross-linked polyolefin insulated wires and cables with 105 °C heat resistance (English PDF)
额定电压450/750V及以下交联聚烯烃绝缘电线和电缆 第2部分:耐热105℃交联聚烯烃绝缘电线和电缆
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 10491.2-2004 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
October 20, 2004
Implementation date
April 1, 2005
Scope
JB/T 10491.2-2004 is the English-translated version of 额定电压450/750V及以下交联聚烯烃绝缘电线和电缆 第2部分:耐热105℃交联聚烯烃绝缘电线和电缆.
JB/T 10491.2-2004 is the Chinese standard "Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750 V - Part 2: Cross-linked polyolefin insulated wires and cables with 105 °C heat resistance".
Its scope clause reads: This part specifies the models, specifications, technical requirements and inspection of cross-linked polyolefin insulated cables with rated voltages up to and including 450/750V and with maximum conductor temperature of 105°C in normal operation.
This part is applicable to copper conductors and cross-linked polyolefin insulated cables (with rated voltages up to and including 450/750V and with maximum conductor temperature of 105°C in normal operation) used for fixed wiring and power and electronic equipment internal connection. Its clauses include service characteristics; models.
Found what you need?
Document preview — JB/T 10491.2-2004
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword i
- 1 Scope
- 2 Normative references
- 3 Service characteristics
- 4 Models
- 5 Specifications
- 6 Technical requirements
- 6.1 Conductor
- 6.2 Insulation
- 6.3 Stranding of insulated cores
- 6.4 Sheath
- 6.5 Overall dimension
- 7 Inspection
- Table 1 Model and name
- Table 2 Specifications
- Table 7 Inspection
1 Scope
This part specifies the models, specifications, technical requirements and inspection of cross-linked polyolefin insulated cables with rated voltages up to and including 450/750V and with maximum conductor temperature of 105°C in normal operation.
This part is applicable to copper conductors and cross-linked polyolefin insulated cables (with rated voltages up to and including 450/750V and with maximum conductor temperature of 105°C in normal operation) used for fixed wiring and power and electronic equipment internal connection.
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of JB/T 10491. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section one: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties (idt IEC 60811-1-1: 1993)
GB/T 2951.2-1997 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section two: Thermal ageing methods (idt IEC 60811-1-2: 1985)
GB/T 2951.3-1997 Common test methods for insulating and sheathing materials of electric cable - Part 1: Methods for general application- Section three: Methods for determining the density - Water absorption tests - Shrinkage test (idt IEC 60811-1-3: 1993)
GB/T 2951.4-1997 Common test methods for insulating and sheathing material of electric cables - Part 1: Methods for general application - Section four: Test at low temperature (idt IEC 60811-1-4: 1985)
GB/T 2951.5-1997 Common test methods for insulating and sheathing materials of electric cables - Part 2: Methods specific to elastomeric compounds - Section one: Ozone resistance test - Hot set test - Mineral oil immersion test (idt IEC 60811-2-1: 1986)
GB/T 3956 Conductors of insulated cables (GB/T 3956-1997, idt IEC 60228: 1978)
GB/T 17650.2 Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity (GB/T 17650.2-1998, idt IEC 60754-2: 1991)
GB/T 17651.2 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements (GB/T 17651.2-1998, idt IEC 61034-2: 1997)
GB/T 18380.1 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable (GB/T 18380.1-2001, idt IEC 60332-1: 1993)
GB/T 18380.2 Tests on electric cables under fire conditions - Part 2: Test on a single small vertical insulated copper wire or cable (GB/T 18380.2-2001, idt IEC 60332-2: 1989)
GB/T 18380.3 Tests on electric cables under fire conditions - Part 3: Test on bunched wires or cables (GB/T 18380.3-2001, idt IEC 60332-3: 1992)
JB/T 10491.1-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V - Part 1: General requirements
3 Service characteristics
The rated voltage of cables, U0/U, shall be 450/750V and 300/500V.
The long-term permissible working temperature of cables shall not be higher than 105°C.
4 Models
See Table 1 for models of cables.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download JB/T 10491.2-2004
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JB/T 10491.3-2004 — Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750 V - Part 3: Cross-linked polyolefin insulated wires and cables with 125 °C heat resistance
JB/T 10491.1-2004 — Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750 V - Part 1: General requirements
JB/T 10491.4-2004 — Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750 V - Part 4: Cross-linked polyolefin insulated cables with 150 °C heat resistance
JB/T 10491.2-2004
$90.00