HJ 880-2017Self-monitoring technology guidelines for pollution sources. Petroleum refining industry (English PDF)
排污单位自行监测技术指南 石油炼制工业
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for HJ 880-2017 in 30 minutes.
Issued by
Ministry of Ecology and Environment
Level / Type
National · Mandatory
Issue date
December 21, 2017
Implementation date
January 1, 2018
Scope
HJ 880-2017 is the English-translated version of 排污单位自行监测技术指南 石油炼制工业.
HJ 880-2017 — This standard proposes the general requirements for self-monitoring by the oil refinery industrial effluent units, the development of monitoring plans, information recording and the basic content and requirements of the report.
This standard applies to the petroleum refining industry sewage units in the production and operation of the discharge of water and air pollutants, noise and the impact on the surrounding environment quality monitoring.
Sewage units own thermal power units (plants), self-supporting boiler requirements in accordance with the HJ 820 implementation.
Found what you need?
Document preview — HJ 880-2017
National Standard of the People's Republic of China
- ICS
- 13.020
- Classification
- Z 05
Issued by: Ministry of Ecology and Environment
Contents
- Foreword .ii
- 1 Scope of application .1
- 2 Normative references .1
- 3 Terms and definitions
- 4 Self-monitoring of the general requirements .2
- 5 Monitoring program development .2
- 6 Information Recording and Reporting .6
- 7 Others
Foreword
To implement the "Law of the People's Republic of China on Environmental Protection," "Water Pollution Prevention and Control Law of the People's Republic of China" and the Law of the People's Republic of China on Prevention and Control of Atmospheric Pollution "to guide and regulate the self-monitoring work by the oil refining industrial sewage units and formulate this standard.
This standard proposes the general requirements for self-monitoring by the oil refinery industrial effluent units, the development of monitoring plans, information recording and the basic content and requirements of the report.
This standard is released for the first time.
This standard by the Environmental Protection Department of Environmental Monitoring Division, Science and Technology Standards Division proposed and organized.
This standard is mainly drafted by. China Environmental Monitoring Station, China Petroleum Group Safety and Environmental Protection Technology Research Institute, Hebei Province Environmental Monitoring Center Station, PetroChina Dushanzi Petrochemical Company Environmental Monitoring Center, PetroChina Natural Gas Co., Ltd. Liaoyang Petrochemical Branch Environmental Monitoring Station.
This standard MEP approved on December 21, 2017.
This standard since January 01, 2018 into effect.
This standard is interpreted by the MEP.
Sewage Unit Self-Monitoring Technical Guide Petroleum Refining Industry
1 Scope of application
This standard proposes the general requirements for self-monitoring by the oil refinery industrial effluent units, the development of monitoring plans, information recording and the basic content and requirements of the report.
This standard applies to the petroleum refining industry sewage units in the production and operation of the discharge of water and air pollutants, noise and the impact on the surrounding environment quality monitoring.
Sewage units own thermal power units (plants), self-supporting boiler requirements in accordance with the HJ 820 implementation.
2 Normative references
This standard references the following documents or the terms of them. For dated references, the effective version is valid Used for this standard.
GB 14554 Odor pollutant emission standards GB 18484 hazardous waste incineration pollution control standards GB 31570 petroleum refining industrial pollutant discharge standards HJ/T 55 Guidelines for Unorganized Emissions Monitoring of Air Pollutants HJ/T 91 Technical Specifications for Surface Water and Sewerage Monitoring HJ/T 164 Groundwater Environmental Monitoring Technical Specifications HJ/T 166 Soil Environmental Monitoring Technical Specifications HJ/T 194 Environmental Air Quality Manual Monitoring Technical Specifications HJ 442 Marine environment monitoring code HJ 664 Technical Specifications for Ambient Air Quality Monitoring Sites (Trial Implementation) HJ 733 Technical Guidelines for the Testing of Volatile Organic Compounds for Leakage and Open Surface Emissions HJ 819 Technical Guidelines for Self-Monitoring of Sewage Disposal Units General HJ 820 Self-Monitoring Technical Guidelines for Sewage Disposal Units Thermal Power Generation and Boilers "National List of Hazardous Wastes" (Ministry of Environmental Protection, National Development and Reform Commission, Ministry of Public Security Order No. 39)
3 Terms and definitions
GB 31570, HJ 819 and defined by the following terms and definitions apply to this standard.
Petroleum refining industry with crude oil, heavy oil as raw materials, the production of gasoline fractions, diesel fractions, fuel oil, lubricants, petroleum wax, oil Green and petrochemical raw materials and other industries.
Volatile organic compounds Refers to the atmospheric photochemical reactions of organic compounds, or according to the prescribed method of measurement or accounting to determine the organic compound Things. This standard uses non-methane total hydrocarbons as a comprehensive control indicator of exhaust and volatile organic compounds at the enterprise boundary.
Hydrogenated crude oil hydrargyrate crude oil this standard specifically refers to the mercury content greater than 5 µg/g of crude oil.
4 Self-monitoring of the general requirements
Sewage units should check their own sources of pollution, pollutants and potential environmental impact indicators, the development of monitoring programs, set and maintain the monitoring facilities, carry out self-monitoring according to the monitoring plan, conduct quality assurance and quality control, record and save the monitoring Data, in accordance with the law to the public monitoring results.
5 Monitoring program development
5.1 Wastewater discharge monitoring
5.1.1 Monitoring point
The pollutant discharging unit shall set the monitoring points at the total waste water discharge and the rainwater discharge. Workshop or production facilities wastewater discharge supervision Set the measuring point in accordance with the provisions of Table 1.
5.1.2 Monitoring indicators and frequency
Wastewater discharge monitoring indicators and the minimum monitoring frequency according to Table 1 implementation.
Table 1 Wastewater discharge monitoring indicators minimum monitoring frequency
Monitoring point monitoring indicators Monitoring frequency Direct emissions indirect emissions Total discharge of waste water Flow, COD, ammonia nitrogen automatic monitoring week Petroleum, pH, suspended solids, total nitrogen, total Phosphorus, sulfide, volatile phenol Zhou Yue on the 5th biochemical oxygen demand, total organic carbon, total vanadium, Benzene, toluene, o-xylene, m-xylene, para Xylene, ethylbenzene, total cyanide Rose quarter Delayed coking unit cold coke water, cut coke water effluent discharge Benzo (a) pyrene six months a Atmospheric and vacuum distillation unit electric desalination wastewater discharge port b Total mercury months Alkyl mercury six months a Acidic water stripping device Wastewater discharge port Total arsenic month FCCU flue gas desulfurization wastewater discharge port Catalytic gasoline adsorption desulfurization device flue gas desulfurization wastewater discharge port Total nickel month Aviation gasoline reconcile workshop wastewater discharge Tetraethyl lead production plant wastewater discharge port Total lead month Rainwater discharge pH, COD, ammonia nitrogen, petroleum, Suspended matter Day c
Note 1. The environmental protection department at the municipal level or above designated by the district explicitly requires that the indicators of pollutants for the automatic monitoring equipment be installed and automatically monitored.
Note 2. Monitoring the concentration of pollutants should be monitored simultaneously flow.
Note. a2020 on January 1 from the monthly implementation.
b for the processing of mercury-containing crude oil situation.
c Monitor emissions by day.
5.2 Exhaust emissions monitoring
5.2.1 Organized emissions monitoring points, indicators and frequency
5.2.1.1 Monitoring points
Exhaust gas discharged through the exhaust pipe to the external environment, etc., should be set in the flue monitoring points; the same monitoring indicators, multiple Exhaust gas mixture should be in the exhaust after the confluence of the common flue or respectively set in each flue monitoring points; there is a bypass of the bypass flue should also set the monitoring point; organic waste gas recovery treatment unit should be set at the inlet and exhaust emissions Measuring point.
5.2.1.2 Monitoring indicators and frequency
Organized emissions monitoring indicators and the minimum monitoring frequency according to Table 2 implementation.
Table 2 Minimum Monitoring Frequency of Organized Exhaust Gas Monitoring Indicators
Monitoring point monitoring indicators monitoring frequency Technology furnace exhaust tube (single rated power >= 14MW) Nitroxide automatic monitoring Sulfur dioxide, particulate matter Quarterly (month a) Process Furnace Exhaust Gas Cylinder (Single Nominal Power 6 Information Recording and Reporting
6.1 Information Recording
6.1.1 Monitoring information record
Manual monitoring records and automatic monitoring of operation and maintenance records in accordance with HJ 819 implementation.
6.1.2 Production and pollution control facilities operating conditions record requirements
6.1.2.1 Production facilities operating conditions
a) main facility
Record the operating status and production load of each unit of each main production unit in normal working conditions by frequency and record each unit the amount of raw materials, the amount of excipients, the output of the main product, the yield of by-products, the water withdrawal (fresh water), the discharge of waste water, the fuel consumption Consumption, sulfur content of fuel, sulfur content of raw materials and various metal content, operating time and other parameters. Catalytic cracking unit also should record the main components of the new catalyst and the amount of waste catalyst emissions, catalyst recycling and so on.
b) Public and auxiliary facilities Including sewage treatment facilities, storage tanks, flare systems, power stations, storage tanks, including design, process parameters (temperature, Liquid level, turnover), etc., the torch system should continuously record the working conditions of the ignition facilities and torch (torch gas flow, torch head temperature Degrees, the fire kind of gas flow, the fire temperature, etc.).
c) the whole plant operation Annual production hours under normal conditions and non-normal conditions (production plant or facilities open down, check maintenance), the use of raw and auxiliary fuels Volume, output of major products and so on. Excipients focus on recording pollution control facilities and pollutant emissions related content.
6.1.2.2 Pollution control facilities operating conditions
Pollution control facilities operation and management information should include the key parameters of equipment operation verification, can fully reflect the production facilities and governance Management of facilities operation and management.
a) The wastewater treatment facilities include two parts. pretreatment facilities and centralized wastewater treatment facilities. The wastewater treatment volume shall be recorded daily, Back to the amount of water, operating parameters (including operating conditions, etc.), dosage, delivery frequency, power consumption, sludge production and so on. Such as Occurrence of facilities outage, inspection and maintenance, accidents and other anomalies, to be recorded.
b) Organized waste gas treatment facilities need to record pollution treatment facilities operating time, operating parameters (including operating conditions, etc.) Use medicine, delivery frequency and so on. In the event of equipment outage, inspection and maintenance, accidents and other anomalies, the need to record.
6.1.3 General Industrial Solid Waste and Hazardous Waste Records
Record the production of general industrial solid waste, comprehensive utilization, disposal capacity, storage; according to the management of hazardous waste Relevant requirements, the daily record of hazardous waste production, comprehensive utilization, disposal, storage and its specific whereabouts. raw material or other hazardous waste generated during the auxiliary process should also be recorded. General Industrial Solid Waste and Hazardous Waste Generation See Table 5.
Table 5 Sources of General Industrial Solid Waste and Hazardous Waste
Category Waste Name
General industrial solid waste ash, gypsum, bag (bag) dust generated by the bag Hazardous waste waste lye, waste acid, spent catalyst, oily sludge and so on.
Note. Other possible hazardous wastes are identified according to the "National List of Hazardous Wastes" or national standards for identification and identification of hazardous wastes.
6.2 Information Report, Emergency Monitoring Report, Information Disclosure
Follow HJ 819.
7 Others
The pollutant discharging entity shall faithfully record the working conditions during the manual monitoring (including the production load and the operation of pollution control facilities, etc.) Ensure monitoring data is representative.
This standard specifies the content, in accordance with HJ 819 implementation.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download HJ 880-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 14554-1993 — Emission standards for odor pollutants
GB 18484-2020 — Standard for pollution control on hazardous waste incineration
GB 31570-2015 — Emission standard of pollutants for petroleum refining industry
Secure payment via Stripe