HJ 787-2016Solid waste. Determination of lead and cadmium. Graphite furnace atomic absorption spectrometry (English PDF)
固体废物 铅和镉的测定 石墨炉原子吸收分光光度法
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for HJ 787-2016 in 30 minutes.
Issued by
Ministry of Ecology and Environment
Level / Type
National · Mandatory
Issue date
March 29, 2016
Implementation date
May 1, 2016
Scope
HJ 787-2016 is the English-translated version of 固体废物 铅和镉的测定 石墨炉原子吸收分光光度法.
HJ 787-2016 — This standard specifies the graphite furnace atomic absorption spectrophotometric method for the determination of lead and cadmium in solid waste and solid waste leachate.
This standard is applicable to the determination of lead and cadmium in solid waste and solid waste leachate. When the amount of solid waste is 0.5 g and the volume of the volume is 25 ml after digestion, the detection limits of lead and cadmium are 0.3 Mg/kg and 0.1 mg/kg, with a lower limit of 1.2 mg/kg and 0.4 mg/kg, respectively.
When the solid waste leachate is sampled in volume 50 ml, digested to 50 ml, the lead and cadmium detection limit were 0.9 µg/L and 0.6 µg/L, the determination of the lower limit Do not be 3.6 µg/L and 2.4 µg/L.
Found what you need?
Document preview — HJ 787-2016
National Standard of the People's Republic of China
- Classification
- Z 13
Issued by: Ministry of Ecology and Environment
Contents
- Preface
- 1 Scope of application
- 2 Normative reference documents
- 3 Principle of the method
- 4 Interference and elimination
- 5 Reagents and materials
- 6 Instruments and equipment
- 7 Samples .3
- 8 Analysis steps
- 9 Results calculation and presentation
- 10 Precision and accuracy
Foreword
In order to implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on the Prevention and Control of Environmental Pollution by Solid Wastes, Protect the environment, protect human health, regulate the solid waste and solid waste leaching solution of lead and cadmium determination method, the development of this standard quasi.
This standard specifies the graphite furnace atomic absorption spectrophotometric method for the determination of lead and cadmium in solid waste and solid waste leachate.
This standard is the first release.
Appendix A and Appendix B of this standard are informative.
This standard is organized by the Ministry of Environmental Protection Science and Technology Standards Division.
The main drafting unit of this standard. Jiangsu Province Environmental Monitoring Center.
The standard verification unit. Nanjing Environmental Monitoring Center Station, Zhejiang Province Environmental Monitoring Center, Shanghai Environmental Monitoring Center, Changzhou City Environmental Monitoring Center Station, Ma On Shan City Environmental Monitoring Center Station, Lianyungang City Environmental Monitoring Center Station.
The environmental protection department of this standard approved on March 29, 2016.
This standard has been implemented since May 1, 2016.
This standard is explained by the Ministry of Environmental Protection.
Solid waste - Determination of lead and cadmium - Graphite furnace atomic absorption spectrophotometric method Warning. nitric acid used in the experiment, perchloric acid with strong oxidizing and corrosive, hydrochloric acid, hydrofluoric acid with strong volatile and corrosive, the operation should be required to wear protective equipment, solution preparation and sample pretreatment process should be in the fume hood into Line operation.
1 Scope of application
This standard specifies the graphite furnace atomic absorption spectrophotometric method for the determination of lead and cadmium in solid waste and solid waste leachate.
This standard is applicable to the determination of lead and cadmium in solid waste and solid waste leachate.
When the amount of solid waste is 0.5 g and the volume of the volume is 25 ml after digestion, the detection limits of lead and cadmium are 0.3 Mg/kg and 0.1 mg/kg, with a lower limit of 1.2 mg/kg and 0.4 mg/kg, respectively. When the solid waste leachate is sampled in volume 50 ml, digested to 50 ml, the lead and cadmium detection limit were 0.9 µg/L and 0.6 µg/L, the determination of the lower limit Do not be 3.6 µg/L and 2.4 µg/L.
2 Normative reference documents
The contents of this standard refer to the following documents or their terms. Those who do not specify the date of the reference file, the effective version of the appropriate for this standard.
Technical specification for SJ sample preparation for industrial solid waste Technical Specification for Hazardous Waste Identification HJ/T 299 Solid waste leaching toxicity leaching method sulfuric acid nitric acid method HJ/T 300 solid waste leaching toxicity leaching method acetic acid buffer solution method HJ 557 Solid waste leaching toxicity leaching method Horizontal oscillation method
3 Principle of the method
Solid waste or solid waste leachate after acid digestion, into the graphite furnace atomizer, after drying, ashing and the original Sub-atomization, as the ground state of the vapor, the element of the hollow cathode lamp or electrodeless discharge lamp emission characteristics of the radiation line selectivity absorb. In a certain concentration range, the absorption intensity and the sample to be measured in proportion to the mass concentration.
4 Interference and elimination
When the mass concentration of Ca in the sample is higher than 500 mg/L, the mass concentration of Fe is higher than 50 mg/L, the mass concentration of Mn is high at 25 mg/L, the determination of lead and cadmium interference, sample dilution method or standard addition method to eliminate its interference. solid Waste matrix composition is more complex, adding matrix modifier ammonium dihydrogen phosphate, can eliminate the organic matter caused by matrix interference. when when the sample matrix composition is unknown or the recoveries are more than the range of the control requirements of this method, the standard addition method should be used to measure and calculate the results, see Appendix A.
5 Reagents and materials
Unless otherwise stated, analytical reagents conforming to national standards are used in the analysis, and the test water is a newly prepared deionized water.
5.1 sulfuric acid. rho (H2SO4) = 1.84 g/ml, excellent grade pure.
5.2 nitric acid. rho (HNO3) = 1.42 g/ml, excellent grade pure.
5.3 hydrochloric acid. rho (HCl) = 1.19 g/ml, excellent grade pure.
5.4 hydrofluoric acid. rho (HF) = 1.49 g/ml, excellent grade pure.
5.5 perchloric acid. rho (HClO4) = 1.68 g/ml, excellent grade pure.
5.6 Hydrogen peroxide. phi (H2O2) = 30%, excellent grade pure.
5.7 Metal Lead. Spectrum Pure.
5.8 Metal cadmium. Spectrum pure.
5.9 Ammonium dihydrogen phosphate (NH4H2PO4). excellent grade pure.
5.10 nitric acid solution. 1 9 (v/v), prepared with nitric acid (5.2).
5.11 nitric acid solution. 1 99 (v/v), prepared with nitric acid (5.2).
5.12 hydrochloric acid solution. 1 1 (v/v), prepared with hydrochloric acid (5.3).
5.13 matrix modifier. ammonium dihydrogen phosphate solution.
Accurately weigh 13.8 g (accurate to 0.0001 g) ammonium dihydrogen phosphate (5.9), dissolved with experimental water and set to 1000 ml.
5.14 lead standard stock solution. rho = 1000 mg/L.
Accurately weigh 1.000 g (accurate to 0.0001 g) of metal lead (5.7), add 15 ml of nitric acid (5.2) to dissolve, if necessary can be dissolved by heating. The whole volume into the 1000 ml volumetric flask, with nitric acid solution (5.11) constant volume to the mark, shake. Can also be used Commercially available standard solution.
5.15 cadmium standard stock solution. rho = 1000 mg/L.
Accurately weigh 1.000 g (accurate to 0.0001 g) of metal cadmium (5.8), add 15 ml of nitric acid (5.2) to dissolve, if necessary can be dissolved by heating. The whole volume into the 1000 ml volumetric flask, with nitric acid solution (5.11) constant volume to the mark, shake. Can also be used Commercially available standard solution.
5.16 Lead Standard Intermediate. rho = 100 mg/L.
Accurate removal of lead standard stock solution (5.14) 10.0 ml in 100 ml volumetric flask, with nitric acid solution (5.11) constant volume to standard Line, shake well. Pro is now available.
5.17 cadmium standard intermediate liquid. rho = 100 mg/L.
Accurate removal of cadmium standard stock solution (5.15) 10.0 ml in 100 ml volumetric flask, with nitric acid solution (5.11) constant volume to standard Line, shake well. Pro is now available.
5.18 lead standard use of liquid. rho = 1.00 mg/L.
Accurate removal of lead standard intermediate (5.16) 1.00 ml in 100 ml volumetric flask, with nitric acid solution (5.11) constant volume to standard Line, shake well. Pro is now available.
5.19 cadmium standard use of liquid. rho = 1.00 mg/L.
Accurate removal of cadmium standard intermediate (5.17) 1.00 ml in 100 ml volumetric flask, with nitric acid solution (5.11) constant volume to standard Line, shake well. Pro is now available.
5.20 high purity argon. purity of not less than 99.999%.
6 Instruments and equipment
6.1 Graphite Furnace Atomic Absorption Spectrophotometer (with background correction function).
6.2 lead hollow cathode lamp, cadmium hollow cathode lamp.
6.3 electric plate or graphite digestion. with temperature control function (temperature stability ± 5 °C), the maximum temperature can be set to.200 °C.
6.4 Microwave digestion. Output power 1000 W ~ 1600 W. With programmable control function, can be temperature, pressure and time (Heating time and holding time) to monitor the whole; with security features.
6.5 Analysis of the balance. accuracy of 0.1 mg.
6.6 Teflon crucible. 50 ml.
6.7 sieve. non-metallic sieve, 100 mesh.
6.8 Common laboratory equipment and equipment.
7 Samples
7.1 Sample collection and storage
The collection and storage of solid waste samples are carried out in accordance with the relevant provisions of HJ/T 20 and HJ/T 298.
7.2 Sample preparation
7.2.1 Solid waste
The preparation of solid waste samples was carried out in accordance with the relevant provisions of HJ/T 20. For solid waste or dry semi-solid waste Product, accurately weighed 10 g (m1, accurate to 0.01 g) sample, naturally air-dried or freeze-dried, weighing again (m2, accurate to 0.01 g), grinding, all over 100 mesh sieve (6.7) standby.
7.2.2 Solid waste leachate
The preparation of solid waste leachate was carried out in accordance with the relevant provisions of HJ/T 299, HJ/T 300 or HJ 557. If the leaching solution does not can be timely analysis, should be added nitric acid (5.2) acidification to pH 8 Analysis steps
8.1 Instrument reference conditions
Different models of graphite furnace atomic absorption spectrophotometer the best measurement conditions are different, according to the instrument manual requirements Optimize test conditions. The instrument reference measurement conditions are shown in Table 3.
Table 3 Instrument reference measurement conditions
Elemental lead (Pb) cadmium (Cd) Determination of wavelength (nm) 283.3 228.8 Lamp current (mA) 8.0 6.0 Passband width (nm) 0.5 0.5 Drying temperature (°C)/time (s) 85 ~ 120/20 85 ~ 120/45 Ashing temperature (° C)/time (s) 400/5 250/5 Atomic temperature (° C)/time (s) 2100/3 1800/3 Elimination temperature (° C)/time (s) 2200/2.2000/3 Whether the atomic phase is stopped Argon flow rate (L/min) 3.0 3.0 Injection volume (l) 20 20 Substrate modifier (l) 5 5
8.2 Standard curve drawing
8.2.1 Lead Standard Curve Series
Respectively, accurate removal of 0.00 ml, 0.50 ml, 1.00 ml, 2.00 ml, 4.00 ml and 5.00 ml lead standard use of liquid (5.18) in a group of 100 ml volumetric flask, with nitric acid solution (5.11) constant volume to the mark, shake. This standard series lead is 0.00 Mg/L, 5.00 µg/L, 10.0 µg/L, 20.0 µg/L, 40.0 µg/L and 50.0 µg/L, respectively. According to the instrument reference conditions (8.1), After adjusting the instrument zero with nitric acid solution (5.11), the standard series was inhaled from low concentration to high concentration, and the corresponding absorbance was measured Degree, with the corresponding absorbance as the ordinate, lead standard series of mass concentration for the abscissa, the establishment of lead calibration curve.
8.2.2 Cadmium standard curve series
0.10 ml, 0.20 ml, 0.30 ml, 0.40 ml and 0.50 ml of cadmium standard solution (5.19), respectively, in a group of.200 ml volumetric flask, with nitric acid solution (5.11) constant volume to the mark, shake. This standard series of cadmium were 0.00 Mg/L, 0.50 µg/L, 1.00 µg/L, 1.50 µg/L, 2.00 µg/L and 2.50 µg/L, respectively. According to the instrument reference conditions (8.1), After adjusting the instrument zero with nitric acid solution (5.11), the standard series was inhaled from low concentration to high concentration, and the corresponding absorbance was measured Degree, with the corresponding absorbance as the ordinate, cadmium standard series of mass concentration for the abscissa, the establishment of cadmium calibration curve.
8.3 Blank sample determination
Prepare a blank sample (7.3.3) and perform the same conditions as the calibration curve.
8.4 Sample determination
The prepared sample (7.3.1 or 7.3.2) was subjected to the same conditions as the established calibration curve.
9 Results calculation and representation
9.1 Results calculation
9.1.1 Solid waste
9.1.1.1 Solid or dry semi-solid solid waste
The content of the element to be measured in solid waste (mg/kg) Calculated according to formula (1) ( ) x -(1) where. - the content of the element to be measured in the solid waste, mg/kg;
- Check the mass concentration of the element in the sample by the calibration curve, mg/L;
0_1 - Mass concentration in the laboratory blank sample, mg/L;
0V - volume of the sample after digestion, ml;
1m - the amount of solid waste sample weighed before drying, g;
2m - the quality of solid waste samples after drying, g;
3m - the amount of sample to be sintered after grinding, g.
9.1.1.2 Semi-solid solid waste with or without drying
The content of the element to be measured in solid waste (mg/kg) Calculated according to formula (2) ( ) Vx -(2) where. - the content of the element to be measured in the solid waste, mg/kg;
- Check the mass concentration of the element in the sample by the calibration curve, mg/L;
0_1 - Mass concentration in the laboratory blank sample, mg/L;
0V - volume of the sample after digestion, ml;
3m - the amount of solid waste sample weighed, g.
9.1.2 Solid waste leachate
Concentration of the element to be measured in the solid waste leachate (mg/L) Calculated according to equation (3).
V001) - (x=
Where. - mass concentration of the element to be tested in the solid waste leachate, mg/L;
1 - Check the mass concentration of the element in the sample by the calibration curve, mg/L;
0_1 - Mass concentration in the laboratory blank sample, mg/L;
V - Sampling volume when digested with solid waste leachate, ml;
0V - solid waste leachate after digestion of the sample volume, ml.
9.2 The result is shown for solid waste, when the result is less than 100 mg/kg, one after the decimal point is retained; when the result is greater than or equal at 100 mg/kg, three valid digits are retained.
For solid waste leachate, when the determination results less than 1.00 mg/L, the retention of two decimal places; when the determination of large at or equal to 1.00 mg/L, retain three valid digits.
10 Precision and accuracy
10.1 Precision
The ESS-1, GSS-1 and ISS-2 standard samples of lead and cadmium were tested six times in six laboratories.
The relative standard deviation...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
How to Download HJ 787-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
HJ 1409-2025 — Technical guidelines for environmental impact assessment - Marine ecology and environment
HJ 1410.1-2025 — Basic dataset of derivation of water quality criteria for aquatic organisms - Part 1: General principles
HJ 1410.10-2025 — Basic dataset of derivation of water quality criteria for aquatic organisms - Part 10: Mollusca
Secure payment via Stripe
Payments accepted
HJ 787-2016
$255.00