HJ 666-2013Water quality. Determination of ammonium nitrogen by flow injection analysis (FIA) and Salicylic acid spectrophotometry (English PDF)
水质 氨氮的测定 流动注射-水杨酸分光光度法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for HJ 666-2013 in 30 minutes.
Issued by
Ministry of Ecology and Environment
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
HJ 666-2013 is the English-translated version of 水质 氨氮的测定 流动注射-水杨酸分光光度法.
HJ 666-2013 — This standard specifies the flow injection analysis-spectrophotometry for the determination of ammonia nitrogen in water. This standard applies to the determination of ammonia nitrogen in surface water, groundwater, domestic sewage and industrial wastewater.
When the detection optical path is 10mm, the detection limit of this method is 0.01mg/L (in N), and the measurement range is 0.04mg/L~5.00mg/L.
Found what you need?
Document preview — HJ 666-2013
National Standard of the People's Republic of China
- ICS
- 13.060
- Classification
- Z 16
Issued by: Ministry of Ecology and Environment
Contents
- Foreword
- 1 Scope of application
- 2 Normative references
- 3 Principle of the method
- 3.1 Working principle of flow injection analyzer
- 3.2 Principles of chemical reactions
- 4 Interference and elimination
- 4.3 When the pH of the sample is >12 or pH5 reagents and materials
- 5.11 Color developer. sodium salicylate solution
- 5.13 Ammonia nitrogen standard stock solution. rho(N)=1000mg/L
- 5.14 Ammonia nitrogen standard use solution. rho(N)=50.0mg/L
- 5.15 Sodium thiosulfate solution. rho=3500mg/L
- 6 Instruments and equipment
- 7 Samples
- 7.1 Sample collection and preservation
- 8.1 Commissioning of the instrument
- 8.2 Calibration
- 8.3 Determination
- 8.4 Blank test
- 9 Calculation and representation of results
- 9.1 Calculation of results
- 9.2 Results representation
- 10 Precision and accuracy
- 10.1 Precision
- 10.2 Accuracy
- 11 Quality Assurance and Quality Control
- 11.1 Blank test
- 11.2 Calibration validity check
- 11.3 Precision Control
- 11.4 Accuracy Control
- 12 Precautions
Foreword
To implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on Water Pollution Prevention and Control, to protect the environment, to ensure human health, standardize the determination method of ammonia nitrogen in water, and formulate this standard.
This standard specifies a flow injection-salicylic acid spectrophotometric method for the determination of ammonia nitrogen in water.
This standard is the first release.
This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection.
This standard is mainly drafted by. Suzhou Environmental Monitoring Center Station and Changshu Environmental Monitoring Station.
This standard is verified by. Water Quality Testing Center of Suzhou Water Supply Company, Nantong Environmental Monitoring Center Station, Jiangsu Province Sea Ocean Fisheries Research Institute, Nanchang Environmental Monitoring Station, East China Normal University Hekou Coastal Science Research Institute and Changshu Environmental Monitoring Station.
This standard was approved by the Ministry of Environmental Protection on October 25, 2013.
This standard has been implemented since January 1, 2014.
This standard is explained by the Ministry of Environmental Protection.
Water quality - Determination of ammonia nitrogen - Flow injection - salicylic acid spectrophotometric method
1 Scope of application
This standard specifies the flow injection analysis-spectrophotometry for the determination of ammonia nitrogen in water.
This standard applies to the determination of ammonia nitrogen in surface water, groundwater, domestic sewage and industrial wastewater.
When the detection optical path is 10mm, the detection limit of this method is 0.01mg/L (in N), and the measurement range is 0.04mg/L~5.00mg/L.
2 Normative references
The contents of this standard refer to the terms in the following documents. For undated references, the valid version applies to this standard.
HJ 536 Water quality - Determination of ammonia nitrogen - Salicylic acid spectrophotometric method HJ/T 91 Surface Water and Wastewater Monitoring Technical Specifications HJ/T 164 Technical Specifications for Groundwater Environmental Monitoring
3 Principle of the method
3.1 Working principle of flow injection analyzer
In a closed pipeline, a volume of sample is injected into a continuous flow of carrier liquid, and the sample and reagent are in a chemical reaction mode.
The blocks are mixed and reacted in a specific order and proportion. Under the condition of incomplete reaction, the flow detection cell is entered for photometric inspection.
Measurement.
3.2 Principles of chemical reactions
In an alkaline medium, ammonia and ammonium ions in the sample react with hypochlorite to form chloramine. At 60 ° C and nitrosyl cyanide in the presence of potassium, chloramine reacts with salicylate to form a blue-green compound, and the absorbance is measured at a wavelength of 660 nm.
Refer to the work flow chart, as shown in Figure 1.
1-peristaltic pump 2 - injection valve 3 - reaction (mixing) ring 4 - heating pool (ring) 60 ° C 5-detection cell 10mm, 660nm R1-buffer solution (5.10) R2-chromogen (5.11) R3-sodium hypochlorite solution (5.12) S-sample C-carrier liquid W-waste liquid
Figure 1 Flow chart of flow injection-salicylic acid spectrophotometric determination of ammonia nitrogen
4 Interference and elimination
4.1 The residual chlorine in the sample will form a chloramine interference assay, which can be removed by adding an appropriate amount of sodium thiosulfate solution (5.15).
4.2 When the concentration of iron and manganese ions in the sample is greater than 500mg/L and 35mg/L, respectively, it will cause positive interference to the analysis;
The turbidity or color can interfere with the measurement. The sample can be pre-distilled with reference to HJ 536. Calcium and magnesium ions in the sample when the chloride ion concentration is not more than 900 mg/L, 1000 mg/L and 100000 mg/L, respectively, there is no effect on the determination of ammonia nitrogen.
4.3 When the pH of the sample is >12 or pH5 reagents and materials
Unless otherwise stated, analytically pure reagents that meet national standards were used for the analysis. Experimental water is freshly prepared, resistor Ammonia-free water with a rate greater than 10 Mohm·cm. In addition to the standard solution, other solutions and experimental water are used with helium (5.17) or ultrasound.
Degas.
5.1 Sulfuric acid. rho(H2SO4) = 1.84 g/ml.
5.2 Ammonium chloride (NH4Cl). excellent grade pure. After drying at a constant temperature of 105 ± 5 ° C ° C, it is stored in a desiccator.
5.3 sodium hydroxide (NaOH).
5.4 Ethylenediaminetetraacetic acid disodium salt (C10H14N2Na2O8·2H2O).
5.5 Disodium hydrogen phosphate (Na2HPO4·7H2O)...
5.6 Sodium salicylate (NaC7H5O3).
5.7 Sodium nitrosoferrocyanide dihydrate (Na2[Fe(CN)5NO]·2H2O).
5.8 sodium thiosulfate (Na2S2O3).
5.9 sodium hypochlorite (NaOCl). a commercially available solution. The effective chlorine content is not less than 5.25%; see the method for determining the effective chlorine concentration.
HJ 536 Appendix A.
5.10 Buffer solution.
Weigh 30g sodium hydroxide (5.3), 25g ethylenediaminetetraacetic acid disodium salt (5.4) and 67g disodium hydrogen phosphate (5.5), dissolve After dissolving in 800 ml of water, dilute to 1000 ml with water and shake well. The solution is stable for 1 month.
5.11 Color developer. sodium salicylate solution
Weigh 144g sodium salicylate (5.6) and 3.5g sodium nitrosoferrocyanide dihydrate (5.7) dissolved in 800ml water, dissolved Dilute to 1000 ml with water and shake well. Stored in a brown bottle, the solution is stored at 4 ° C for 1 month.
5.12 sodium hypochlorite use solution.
Measure 60 ml of sodium hypochlorite solution (5.9), dilute to 1000 ml with water, and shake well. Available at the time of use.
5.13 Ammonia nitrogen standard stock solution. rho(N)=1000mg/L
Weigh 3.819g of ammonium chloride (5.2) dissolved in water, dissolve it, transfer it to a 1000ml volumetric flask, dilute to volume with water and mix. The the solution was stored at 4 ° C and was stable for 6 months. Or buy a commercially available certified reference material directly.
5.14 Ammonia nitrogen standard use solution. rho(N)=50.0mg/L
Measure 5.00 ml of ammonia nitrogen standard stock solution (5.13), transfer to a 100 ml volumetric flask, dilute to volume with water and mix. The solution the solution is stored at 4 ° C and is stable for 1 month.
5.15 Sodium thiosulfate solution. rho=3500mg/L
3.5 g of sodium thiosulfate (5.8) was weighed and dissolved in water and diluted to 1000 ml with water.
5.16 Aqueous filter. The pore size is 0.45 µm.
5.17 Helium. Purity >=99.99%.
6 Instruments and equipment
6.1 Flow injection analyzer. autosampler, chemical reaction unit (ie chemical reaction module, channel. by peristaltic pump, note the injection valve, the reaction line, etc., the detection unit (the flow path of the flow detection cell is 10 mm) and the data processing unit.
6.2 Balance. The accuracy is 0.0001g.
6.3 Centrifuge. Maximum speed 4000r/min.
6.4 Pre-distillation unit. consists of a 500ml Kay flask, nitrogen ball, straight condenser and conduit. The end of the condenser can be connected to a A dropper of appropriate length is placed so that the tip of the outlet is immersed under the surface of the absorbing liquid.
6.5 Ultrasonic machine. frequency 40KHz.
6.6 Common instruments and equipment used in general laboratories.
7 Samples
7.1 Sample collection and preservation
Samples should be collected in polyethylene or glass bottles and analyzed as soon as possible. If necessary, add sulfuric acid (5.1) to pH8 Analysis steps
8.1 Commissioning of the instrument
Install the analysis system, set the operating parameters, and operate the instrument according to the instrument manual. After starting the machine, first replace the reagent with water, check Check the tightness of the flow path and the smoothness of the liquid flow. After the baseline has stabilized (about 15 minutes), the system begins to test After the baseline is stabilized again, proceed to 8.2~8.4.
8.2 Calibration
8.2.1 Preparation of the standard series
Transfer the appropriate amount of ammonia nitrogen standard solution (5.14) separately, dilute to 100ml with water, and prepare the standard for 6 concentration points.
Quasi-series. Ammonia nitrogen concentrations were. 0.00 mg/L, 0.05 mg/L, 0.25 mg/L, 0.50 mg/L, 2.50 mg/L, and 5.00 mg/L, respectively.
8.2.2 Drawing of the calibration curve
Measure the appropriate standard series (8.2.1), place in the sample cup, and take the sample from the low concentration to the high concentration according to the program.
Sample, measurement. Taking the measured signal value (peak area) as the ordinate, the corresponding ammonia nitrogen concentration (in N, mg/L) is the abscissa, Draw a calibration curve.
8.3 Determination
The measurement of the sample (7.2) was carried out under the same conditions as in the drawing of the calibration curve.
Note. If the ammonia nitrogen content of the sample exceeds the detection range of the calibration curve, the appropriate amount of the sample should be diluted and measured on the machine.
8.4 Blank test
Replace the sample with experimental water and perform a blank test in accordance with step 8.3.
9 Calculation and representation of results
9.1 Calculation of results
The mass concentration of ammonia nitrogen in the sample (in N, mg/L) is calculated according to formula (1).
Yaf
rho -= × (1)
In the formula.
rho--the mass concentration of ammonia nitrogen in the sample, mg/L;
y -- determine the signal value (peak area);
a -- the intercept of the calibration curve equation;
b -- the slope of the calibration curve equation;
f -- dilution factor.
9.2 Results representation
When the measurement result is less than 1.00 mg/L, the result is retained to two decimal places; when it is greater than or equal to 1.00 mg/L, the result Keep three significant digits.
10 Precision and accuracy
10.1 Precision
Six laboratories tested the uniform samples with ammonia nitrogen concentrations of 0.02 mg/L, 0.54 mg/L, and 2.74 mg/L.
The relative standard deviations in the laboratory are. 1.2%~8.6%, 0.3%~1.0%, 0.2%~0.7%;
The quasi-bias were. 4.6%, 1.5%, 1.7%; the repeatability limits were. 0.003mg/L, 0.010mg/L, 0.037mg/L;
The reproducibility limits were. 0.004 mg/L, 0.025 mg/L, and 0.134 mg/L, respectively.
10.2 Accuracy
Six laboratories had ammonia nitrogen concentrations of 0.54 mg/L ± 0.03 mg/L, 1.33 ± 0.03 mg/L, and 2.74 ± 0.12 mg/L, respectively.
Determination of the standard substance. relative error. 0.2% ~ 3.2%, 0.0% ~ 3.1%, 0.7% ~ 2.6%; relative error the final values were. 1.6% ± 2.8%, 1.7% ± 2.6%, 1.7% ± 1.6%.
The concentrations of ammonia nitrogen in the six laboratories were 0.05 mg/L ~ 0.45 mg/L, 0.44 mg/L ~ 1.70 mg/L, and 1.08 mg/L, respectively.
~2.20 mg/L 3 kinds of actual samples (surface water, domestic sewage, industrial wastewater) were spiked and measured, and the recoveries were spiked.
For. 104%~114%, 98%~105%, 93.8%~104%; the final recoveries of the spiked recovery are. 108%±7.8%, 101% ± 4.8%, 98.9% ± 7.2%.
11 Quality Assurance and Quality Control
11.1 Blank test
At least 2 blank samples shall be measured for each batch of samples, and the blank value shall not exceed the method detection limit. Otherwise, the cause should be ascertained.
The sample can be measured after reanalysis until it is qualified.
11.2 Calibration validity check
A calibration curve must be drawn for each batch of samples. The correlation coefficient of the calibration curve is gamma >= 0.995.
For each sample analyzed, a calibration curve intermediate concentration solution is used for calibration verification, and the measurement results are relatively biased.
The difference should be <= 5%, otherwise the calibration curve should be redrawn.
11.3 Precision Control
At least 10% of the parallel samples should be determined for each batch of samples. When the number of samples is less than 10, at least one parallel sample should be determined.
When the ammonia nitrogen concentration of the sample is <=0.10 mg/L, the allowable relative deviation of the parallel sample is <=20%; when the ammonia nitrogen concentration is when 0.10~1.0mg/L, the allowable relative deviation of parallel samples is <=15%; when the ammonia nitrogen concentration is >1.0mg/L, the allowable phase of parallel samples the deviation is <=10%.
11.4 Accuracy Control
At least 10% of the spiked sample shall be determined for each batch of samples. When the number of samples is less than 10, at least one spiked sample shall be determined.
The spiked recovery rate should be between 80% and 120%.
If necessary, each batch of samples shall have at least one known quality control sample, and the test results shall be in the uncertainty given by it.
Inside.
12 Precautions
12.1 Reagent and ambient temperature influence analysis results, the reagents stored in the refrigerator should be placed at room temperature (20 ± 5 ° C) before use.
The room temperature fluctuation during the analysis cannot exceed ± 2 °C.
12.2 In order to reduce baseline noise, the reagent should be kept clear and the reagent should be filtered if necessary; due to sodium hypochlorite solution (effective chlorine content) the instability of 5.25%), pay attention to the preservation and use of the reagent, if the slope of the calibration curve is 30% lower than the normal value (The effective chlorine content drops to 2.62%) and new reagents must be replaced. If there is a bubble in a closed chemical reaction system, it will interfere with the measurement.
Therefore, all solutions except the standard solution must be degassed, and degassed by helium for 1 min or ultrasonic degassed for 30 min.
12.3 After the analysis is completed every day, the analytical pipeline is cleaned with pure water, and the filter in the flow detection tank is removed in time.
Put it into the dryer, it is dustproof and moisture proof.
12.4 During the analysis, the detected peak-to-peak anomaly is found. In general, the flat peak is over-range and the double-peak is matrix interference.
The peak is blocked by the pump tube or the reagent is invalid.
12.5 Different types of flow analyzers can refer to this standard to select the appropriate instrument conditions.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
Cited by
- GB 4287-2026Discharge standard of water pollutants for textile industry
- GB/T 47215-2026Determination of ammonia volatilization from soil
- GB 46817-2025Discharge standard of water pollutants for food processing and manufacturing industry
- GB 16889-2024Standard for pollution control on the landfill site of municipal solid waste
- GB 18598-2019Standard for pollution control on the hazardous waste landfill
How to Download HJ 666-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
HJ 1409-2025 — Technical guidelines for environmental impact assessment - Marine ecology and environment
HJ 1410.1-2025 — Basic dataset of derivation of water quality criteria for aquatic organisms - Part 1: General principles
HJ 1410.10-2025 — Basic dataset of derivation of water quality criteria for aquatic organisms - Part 10: Mollusca
Secure payment via Stripe
Payments accepted
HJ 666-2013
$105.00