HJ 629-2011Stationary source emission - Determination of sulphur dioxide - Non-dispersive infrared absorption method (English PDF)
固定污染源废气 二氧化硫的测定 非分散红外吸收法
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for HJ 629-2011 in 30 minutes.
Issued by
State Environmental Protection Administration State Environmental Protection Administration of People's Republ
Level / Type
National · Mandatory
Issue date
September 8, 2011
Implementation date
November 1, 2011
Scope
HJ 629-2011 is the English-translated version of 固定污染源废气 二氧化硫的测定 非分散红外吸收法.
HJ 629-2011 — This Standard specifies the non-dispersive infrared absorption method that is to determine the sulphur dioxide from organized exhausted gas of stationary source.
This Standard is applicable to instantaneous monitoring and continuous monitoring on sulphur dioxide from organized exhausted gas of stationary source. The detection limit of this method is 3 mg/m3; the lower limit of determination is 10 mg/m3.
Found what you need?
Document preview — HJ 629-2011
National Standard of the People's Republic of China
Issued by: State Environmental Protection Administration State Environmental Protection Administration of People's Republ
Contents
- Foreword...4
- 1 Scope...5
- 2 Normative references...5
- 3 Method-principle...5
- 4 Interference and elimination...6
- 5 Reagents and materials...6
- 6 Apparatus and equipment...6
- 7 Analysis step...7
- 8 Result calculation and representation...8
- 9 Precision and accuracy...9
- 10 Quality control and quality assurance...10
- 11 Precautions...10
Foreword
This Standard was formulated in order to implement "Environmental Protection
Law of the People's Republic of China" and "Law of the People's Republic of
China on the Prevention and Control of Atmospheric Pollution", protect the
environment, safeguard human health and standardize the determination of
sulfur dioxide from exhausted gas of stationary source.
This Standard specifies the non-dispersive infrared absorption method in the
determination of sulfur dioxide from exhausted gas of stationary source.
This Standard was formulated for the first time.
The formulation of this Standard was organized by Department of Science,
Technology and Standards of State Environmental Protection Administration.
Main drafting organization of this Standard. Sino-Japan Friendship Center for
Environmental Protection.
The verification organizations of this Standard. National Research Center for
Environmental Analysis and Measurement, Beijing Municipal Environmental
Protection Monitoring Center, Shenyang Environmental Monitoring Central
Station, Shanghai Baoshan District Environmental Monitoring Station, and
Beijing University of Chemical Technology.
This Standard was approved by State Environmental Protection Administration
on September 8, 2011.
This Standard shall be implemented since November 1, 2011.
This Standard shall be interpreted by State Environmental Protection
Administration.
Stationary source emission
- determination of sulphur dioxide
- Non-dispersive infrared absorption method
1 Scope
This Standard specifies the non-dispersive infrared absorption method that is
to determine the sulphur dioxide from organized exhausted gas of stationary
source.
This Standard is applicable to instantaneous monitoring and continuous
monitoring on sulphur dioxide from organized exhausted gas of stationary
source. The detection limit of this method is 3 mg/m3; the lower limit of
determination is 10 mg/m3.
2 Normative references
The following standards contain the provisions which, through reference in this
Standard, constitute the provisions of this Standard. For undated references,
the effective edition of the referenced document applies.
GB/T 16157 The determination of particulates and sampling methods of
gaseous pollutants emitted from exhaust gas of stationary source
HJ/T 47 Technical conditions of sampler for stack gas
HJ/T 75 Specifications for continuous emissions monitoring of flue gas
emitted from stationary sources (on trial)
HJ/T 76 Specification and test procedures for continuous emission
monitoring systems of flue gas emitted from stationary sources (on trial)
HJ/T 397 Technical specifications for emission monitoring of stationary
source
3 Method-principle
Sulfur dioxide gas is selectively absorbable in infrared spectrum of which the
wavelength is 6.82 ~ 9 µm. When a beam of infrared light of which the constant
x(SO2) - sulfur dioxide of mole fraction in determined gas, µmol/mol;
2.86 - conversion factor for converting sulfur dioxide's mass concentration
TO the mass concentration under standard conditions.
8.1.3 Calculation of sulfur dioxide's emission rate
Where,
G - sulfur dioxide's emission rate, kg/h;
rho – mass concentration of sulfur dioxide in dry exhaust gas, (mg/m3);
Qsn - dry exhaust gas flow under standard conditions (273K, 101.325 kPa),
m3/h.
8.2 Result representation
The calculation results of sulfur dioxide's concentration and emission rate shall
be rounded off to three significant digits.
9 Precision and accuracy
9.1 Precision
Six laboratories have determined the unified simulated gas samples of which
the sulfur dioxide concentrations are 64 mg/m3, 116 mg/m3, and 268 mg/m3
respectively.
Relative standard deviations in laboratories are respectively. 0.4%~3.4%,
0.3%~1.8%, 0.1%~0.8%;
Relative standard deviations among laboratories are respectively. 3.0%,
1.0%, 0.3%;
Repeatability limits are. 2.7 mg/m3, 2.8 mg/m3, 3.0 mg/m3;
Reproducibility limits are. 5.9 mg/m3, 4.1 mg/m3, 3.5 mg/m3.
9.2 Accuracy
Six laboratories have determined the certified reference gases of which the
sulfur dioxide concentrations are 146 mg/m3, 636 mg/m3, and 1403 mg/m3
respectively.
Relative errors are respectively. 0~1.5%, 0.1%~0.9%, 0.1%~0.7%;
Final values of relative errors are. 0.5%±1.1%, 0.4%±0.6%, 0.3%±0.4%.
10 Quality control and quality assurance
10.1 The dew-point temperature of the sample gas must be lower than ambient
temperature. When sample gas has moisture, it shall use dehumidifier to
reduce the dew-point temperature to 5°C. The dehumidifier shall make the
determined sulfur dioxide's loss in the dehumidified gas not to be greater than
5%.
10.2 When determining sulfur dioxide, it shall choose the instrument of which
the ability of resisting negative pressure is better than negative pressure of gas
duct, so as to avoid the instrument's sampling flow reduces and causes the
determination result lower or unable to be determined.
10.3 When sample gas has sulfur dioxide or other aerial fog, it shall use mist
filter or condenser to filter.
10.4 Before and after determination each time, it shall check the tightness of
determination system, and use standard gas to calibrate.
10.5 The sample gas temperature that is directly imported into the analyzer
shall not be greater than 50°C.
11 Precautions
11.1 In order to prevent the moisture in sampling gas being condensed in the
connecting pipe and in the instrument, which will interfere the determination,
the sampling tube and dehumidifier shall be heated to 120°C before sampling,
so as to prevent the moisture in the sample being condensed in the sampling
pipeline.
11.2 When connecting the sampling tube with heating and dehumidifying
devices to the instrument's air inlet, the connecting pipe line shall be as short
as possible. In case of using long pipe line, it shall prevent the moisture in the
sample gas being condensed.
11.3 The sampling gas shall be filtered before it is going into the analyzer, so
as to eliminate the particulate matter in the sampling gas. Before determination
begins, it shall check the dehumidifier and the gas pipeline, and clean the filter
for particulate matter of sampling preprocessor. Replace filtering material when
necessary. During determining, it shall always monitor the flow rate changes,
clean timely and replace smoke filtering device.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
Normative references
How to Download HJ 629-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16157-1996 — Determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source
HJ 1409-2025 — Technical guidelines for environmental impact assessment - Marine ecology and environment
HJ 1410.1-2025 — Basic dataset of derivation of water quality criteria for aquatic organisms - Part 1: General principles
Secure payment via Stripe
Payments accepted
HJ 629-2011
$85.00